Search NASA⌕ Search

Engineering topics

Odabashian, J. A.

Publications and source records attributed to Odabashian, J. A..

Determinants of diastolic myocardial tissue Doppler velocities: influences of relaxation and preload

Myocardial tissue Doppler echocardiography (TDE) has been proposed as a tool for the assessment of diastolic function. Controversy exists regarding whether TDE measurements are influenced by preload. In this study, left ventricular volume and high-fidelity pressures were obtained in eight closed-chest dogs during intermittent caval occlusion. The time constant of isovolumic ventricular relaxation (tau) was altered with varying doses of dobutamine and esmolol. Peak early diastolic myocardial (E(m)) and transmitral (E) velocities were measured before and after preload reduction. The relative effects of changes in preload and relaxation were determined for E(m) and compared with their effects on E. The following results were observed: caval occlusion significantly decreased E (DeltaE = 16.4 +/- 3.3 cm/s, 36.6 +/- 13.7%, P < 0.01) and E(m) (DeltaE(m) = 1. 3 +/- 0.4 cm/s, 32.5 +/- 26.1%, P < 0.01) under baseline conditions. However, preload reduction was similar for E under all lusitropic conditions (P = not significant), but these effects on E(m) decreased with worsening relaxation. At tau < 50 ms, changes in E(m) with preload reduction were significantly greater (DeltaE(m) = 2.8 +/- 0.6 cm/s) than at tau = 50-65 ms (DeltaE(m) = 1.2 +/- 0.2 cm/s) and at tau >65 ms (DeltaE(m) = 0.5 +/- 0.1 cm/s, P < 0.05). We concluded that TDE E(m) is preload dependent. However, this effect decreases with worsening relaxation.

NASA Discipline Cardiopulmonary↗

Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm: in vitro and in vivo studies

OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.

NASA Discipline Cardiopulmonary↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗