Search NASA⌕ Search

NASA NTRS · 20040088249

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

Abstract

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Qin, J. J., Jones, M., Shiota, T., Greenberg, N. L., Firstenberg, M. S., Tsujino, H., Zetts, A. D., Sun, J. P., Cardon, L. A., Odabashian, J. A., Flamm, S. D., White, R. D., Panza, J. A., Thomas, J. D.. 2000-06-01. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging. https://ntrs.nasa.gov/citations/20040088249

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Elastic model for crimped collagen fibrils

A physiologic constitutive expression is presented in algorithmic format for the nonlinear elastic response of wavy collagen fibrils found in soft connective tissues. The model is based on the observation that crimped fibrils in a fascicle have a three-dimensional structure at the micron scale that we approximate as a helical spring. The symmetry of this wave form allows the force/displacement relationship derived from Castigliano's theorem to be solved in closed form: all integrals become analytic. Model predictions are in good agreement with experimental observations for mitral-valve chordae tendinece.

Evaluation Studies↗

Length dependence of carbon nanotube thermal conductivity and the "problem of long waves"

We present the first calculations of finite length carbon nanotube thermal conductivity that extend from the ballistic to the diffusive regime, throughout a very wide range of lengths and temperatures. The long standing problem of vanishing scattering of the "long wavelength phonf dramatically here, making the thermal conductivity diverge as the nanotube length increases. We show that the divergence disappears if 3-phonon scattering processes are considered to second or higher order. Nevertheless, for defect free nanotubes, the thermal conductivity keeps increasing up to very large lengths (10 gm at 300 K). Defects in the nanotube are also able to remove the long wavelength divergence.

Evaluation Studies↗

Use of multiresolution wavelet feature pyramids for automatic registration of multisensor imagery

The problem of image registration, or the alignment of two or more images representing the same scene or object, has to be addressed in various disciplines that employ digital imaging. In the area of remote sensing, just like in medical imaging or computer vision, it is necessary to design robust, fast, and widely applicable algorithms that would allow automatic registration of images generated by various imaging platforms at the same or different times and that would provide subpixel accuracy. One of the main issues that needs to be addressed when developing a registration algorithm is what type of information should be extracted from the images being registered, to be used in the search for the geometric transformation that best aligns them. The main objective of this paper is to evaluate several wavelet pyramids that may be used both for invariant feature extraction and for representing images at multiple spatial resolutions to accelerate registration. We find that the bandpass wavelets obtained from the steerable pyramid due to Simoncelli performs best in terms of accuracy and consistency, while the low-pass wavelets obtained from the same pyramid give the best results in terms of the radius of convergence. Based on these findings, we propose a modification of a gradient-based registration algorithm that has recently been developed for medical data. We test the modified algorithm on several sets of real and synthetic satellite imagery.

Evaluation Studies↗