Search NASASearch

Engineering topics

Palmer, D.

Publications and source records attributed to Palmer, D..

At least 19 records

GRB 080407: An Ultra-long Burst Discovered by the IPN

We present observations of the extremely long GRB 080704 obtained with the instruments of the Interplanetary Network (IPN). The observations reveal two distinct emission episodes, separated by a approx.1500 s long period of quiescence. The total burst duration is about 2100 s. We compare the temporal and spectral characteristics of this burst with those obtained for other ultra-long GRBs and discuss these characteristics in the context of different models.

Cummings, J

Prompt Emission Properties of Swift GRBs

We present the results from the second Swift BAT catalog of 476 gamma-ray bursts, which contains bursts detected by the BAT between 2004 December 19 and 2009 December 21. In addition to the spectral and temporal parameters extracted from the first BAT GRB catalog, 3324 time-resolved spectra have been extracted and analyzed. We show and discuss 1) the duration distribution, 2) the hardness of short GRBs, 3) Epeak distribution, 4) the line of death problem and 5) an additional power-law component in the prompt emission spectrum.

Sakamoto, T.

Global Properties of X-Ray Flashes and X-Ray-Rich GRBs Observed by Swift

We describe and discuss the spectral and temporal characteristics of the prompt emission and X-ray afterglow emission of X-ray flashes (XRFs) detected and observed by Swift between December 2005 and September 2006. We compare these characteristics to a sample of X-ray rich gamma-ray bursts (XRRs) and conventional classical gamma-ray bursts (C-GRBs)observed during the same period. We confirm the correlation between Epeak and fluence noted by others and find further evidence that XRFs and C-GRBs form a continuum. We also confirmed that our known redshift samples are consistent with the correlation between the peak energy (Epeak) and the isotropic radiated energy (Eiso), so called the Epeak-Eiso relation. The spectral properties of X-ray afterglows are similar to those of gamma-ray burst afterglows, but the temporal properties of the two classes are quite different. We found that the light curves of C-GRBs afterglow show a break to steeper indices (shallow-to-steep break) at much earlier times than do XRF afterglows. Moreover, the overall luminosity of X-ray afterglows of XRFs are systematically smaller by a factor of two or more compared with that of C-GRBs. These distinct differences in the X-ray afterglow between XRFs and C-GRBs are key to understanding not only a mysterious shallow-to-steep phase in the X-ray afterglow but also the unique nature of XRFs.

Sakamoto, T.

Long Baseline Nulling Interferometry with the Keck Telescopes: A Progress Report

The Keck Interferometer Nuller (KIN) is one of the major scientific and technical precursors to the Terrestrial Planet Finder Interferometer (TPF-I) mission. KIN's primary objective is to measure the level of exo-zodiacal mid-infrared emission around nearby main sequence stars, which requires deep broad-band nulling of astronomical sources of a few Janskys at 10 microns. A number of new capabilities are needed in order to reach that goal with the Keck telescopes: mid-infrared coherent recombination, interferometric operation in 'split pupil' mode, N-band optical path stabilization using K-band fringe tracking and internal metrology, and eventually, active atmospheric dispersion correction. We report here on the progress made implementing these new functionalities, and discuss the initial levels of extinction achieved on the sky.

instrumentation

The Keck Interferometer Nuller: System Architecture and Laboratory Performance

The first high-dynamic-range interferometric mode planned to come on line at the Keck Observatory is mid-infrared nulling. This observational mode, which is based on the cancellation of the on-axis starlight arriving at the win Keck telescopes, will be used to examine nearby stellar systems for the presence of circumstellar exozodiacal emission. This paper describes the system level layout of the Keck Interferometer Nuller (KIN), as well as the final performance levels demonstrated in the laboratory integration and test phase at the Jet Propulsion Laboratory prior to shipment of the nuller hardware to the Keck Observatory in mid-June 2004. On-sky testing and observation with the mid-infrared nuller are slated to begin in August 2004.

interferometry

Swift Burst Alert Telescope (BAT) Instrument Response

The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.

Parsons, A.

Overview of the control for the Keck Interferometer

This paper gives an overview of the control system that has been implemented for the single baseline operation of the Keck Interferometer and indicates how this will be extended to allow control of the future modes of the instrument.

Keck Interferometer interferometry real time contr

The Keck interferometer autoaligner

A key thrust of NASA's Origins program is the development of astronomical interferometers. Pursuing this goal in a cost-effective and expedient manner from the ground has led NASA to develop the Keck Interferometer, which saw first fringes between the twin 10m Keck telescopes in March of 2001.

Keck

Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is an infrared, phase-tracking interferometer in operation at Palomar Mountain since July 1995. It was funded by NASA for the purpose of developing techniques and methodologies for doing narrow-angle astrometry for the purpose of detecting extrasolar planets.

optical

BASIS: A new GRB mission concept

The burst acrsecond imaging and spectroscopy (BASIS) mission concept is reviewed. The scientific objectives of the mission are to accurately locate bursts, determine their distance scale and measure the physical characteristics of the emission region. Arcsecond burst positions would be obtained for approximately 100 bursts/yr in the 10 to 200 keV emission region, allowing deep, unconfused counterpart surveys at other wavelengths. The key enabling technology development is the production of CdZnTe room temperature semiconductor detectors with a spatial resolution of the order of 100 microns. Fine spectroscopy would be obtained between 0.2 and 200 keV. The 0.2 keV threshold would allow measurements of the absorption in our Galaxy and possible host galaxies.

Teegarden, B. J.

BATSE gamma-ray burst line search. 2: Bayesian consistency methodology

We describe a Bayesian methodology to evaluate the consistency between the reported Ginga and Burst and Transient Source Experiment (BATSE) detections of absorption features in gamma-ray burst spectra. Currently no features have been detected by BATSE, but this methodology will still be applicable if and when such features are discovered. The Bayesian methodology permits the comparison of hypotheses regarding the two detectors' observations and makes explicit the subjective aspects of our analysis (e.g., the quantification of our confidence in detector performance). We also present non-Bayesian consistency statistics. Based on preliminary calculations of line detectability, we find that both the Bayesian and non-Bayesian techniques show that the BATSE and Ginga observations are consistent given our understanding of these detectors.

Band, D. L.