Search NASA⌕ Search

NASA NTRS · 20070031984

Long Baseline Nulling Interferometry with the Keck Telescopes: A Progress Report

Abstract

The Keck Interferometer Nuller (KIN) is one of the major scientific and technical precursors to the Terrestrial Planet Finder Interferometer (TPF-I) mission. KIN's primary objective is to measure the level of exo-zodiacal mid-infrared emission around nearby main sequence stars, which requires deep broad-band nulling of astronomical sources of a few Janskys at 10 microns. A number of new capabilities are needed in order to reach that goal with the Keck telescopes: mid-infrared coherent recombination, interferometric operation in 'split pupil' mode, N-band optical path stabilization using K-band fringe tracking and internal metrology, and eventually, active atmospheric dispersion correction. We report here on the progress made implementing these new functionalities, and discuss the initial levels of extinction achieved on the sky.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mennesson, Bertrand, Akeson, R., Appleby, E., Bell, J., Booth, A., Colavita, M. M., Crawford, S., Creech-Eakman, M. J., Dahl, W., Fanson, J., Felizardo, C., Garcia, J., Gathright, J., Herstein, J., Hovland, E., Hrynevych, M., Johansson, E., Koresko, C., Mignant, D. Le, Ligon, R., Millan-Gabet, R., Moore, J., Neyman, C., Palmer, D., Panteleeva, T.. 2005-10-03. Long Baseline Nulling Interferometry with the Keck Telescopes: A Progress Report. https://ntrs.nasa.gov/citations/20070031984

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm 2 . Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

instrumentation↗

Remote Recession Sensing of Ablative Heat Shield Materials

Tests were performed to demonstrate the feasibility of a new method of measuring surface recession of a material sample during arc-jet testing in the NASA Ames mARC subscale developmental facility. The measurement principle was inspired through tracer elements such as Ca and Na which were seen in the spectra taken during the airborne observation campaign of the Stardust re-entry and which could be clearly observed standing out against the emission spectra emitted by postshock layer and glowing surface of the re-entry capsule. The measurement principle involves seeding of the heat shield materials at a defined depth with tracer elements which show strong and characteristic emission lines in the post shock plasma. Once the material recession reaches the seeding depth, these elements get into the hot plasma and show up in the emission spectra. The methodology was successfully demonstrated during arc-jet testing of phenolic impregnated carbonablator (PICA) material which was seeded in depth with a mixture of NaCl and MgCl in powder form. In the emission spectroscopy data, the emission lines of Mg and Na showed up about 1.5 seconds after probe insertion into the arc-jet plasma and vanished after another 2.5 seconds when recessionhad consumed the seeding material. From these data, a recession rate of about 1 mm/s is estimated.The heat flux during the test was measured to be 2575 W/sq cm on a hemispherical heat flux probewhich corresponds to a heat flux of 1036 W/sq cm on the rectangular test articles. An estimate for a lower limit of the surface temperature of 2800K during the test was obtained by fitting Planck radiation to the continuum spectra emitted by the PICA sample. Typical recession rates of PICA during testing in the large arc-jet facilities at similar test conditions are reported to be on the order of 0.05 to 0.1 cm/s which agrees well with the recession rates of 0.05-0.06 cm/s estimated from the emission spectroscopy data. Further tests under better controlled conditions are suggested to quantify this measurement method. Through a different choice of seeding materials with lower melting point, an extension of the measurement principle to monitor char depth seems feasible but was not yet demonstrated. Possible applications besides ground testing are recession and possibly char depth measurements during real re-entry. Detection through emission spectroscopy could be accomplished through ground based or airborne observation as performed during the Stardust and Hayabusa re-entries, or through on-board spectrometers. A suitable mission would be the re-entryof the OSIRIS-REX mission planned for late 2023. The measured data are presented and interpreted, the results and details of future applications are discussed.

instrumentation↗

Remote Recession Sensing of Ablative Heat Shield Materials

Material recession and charring are two major processes determining the performance of ablative heat shield materials. Even in ground testing, the characterization of these two mechanisms relies on measurements of material thickness before and after testing, thus providing only information integrated over the test time. For recession measurements, optical methods such as imaging the sample surface during testing are under investigation but require high alignment and instrument effort, therefore being not established as a standard measurement method. For char depth measurements, the most common method so far consists in investigation of sectioned samples after testing or in the case of Stardust where core extractions were performed to determine char information. In flight, no reliable recession measurements are available, except total recession after recovering the heat shield on ground. Developments of mechanical recession sensors have been started but require substantial on board instrumentation adding mass and complexity. In this work, preliminary experiments to evaluate the feasibility of remote sensing of material recession and possibly char depth through optically observing the emission signatures of seeding materials in the post shock plasma is investigated. It is shown that this method can provide time resolved recession measurements without the necessity of accurate alignment procedures of the optical set-up and without any instrumentation on board of a spacecraft. Furthermore, recession data can be obtained without recovering flight hardware which would be a huge benefit for inexpensive heat shield material testing on board of small re-entry probes, e.g. on new micro-satellite re-entry probes as a possible future application of Cubesats or RBR

instrumentation↗