Search NASA⌕ Search

Engineering topics

Patel, U.

Publications and source records attributed to Patel, U..

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Ground-state and decay properties of neutron-rich 106 Nb

The ground-state properties of neutron-rich 106 Nb and its β decay into 106 Mo have been studied using the CARIBU radioactive-ion-beam facility at Argonne National Laboratory. Niobium-106 ions were extracted from a 252 Cf fission source and mass separated before being delivered as low-energy beams to the Canadian Penning Trap, as well as the X-Array and SATURN β-decay-spectroscopy station. The measured 106 Nb ground-state mass excess of –66202.0(13) keV is consistent with a recent measurement but has three times better precision; this work also rules out the existence of a second long-lived, β-decaying state in 106 Nb above 5 keV in excitation energy. The decay half-life of 106 Nb was measured to be 1.097(21) s, which is 8% longer than the adopted value. Here, the level scheme of the decay progeny, 106 Mo, has been expanded up to ≈ 4 MeV. The distribution of decay strength and considerable population of excited states in 106 Mo of J ≥ 3 emphasizes the need to revise the adopted J π = 1 – ground-state spin-parity assignment of 106 Nb; it is more likely to be J ≥ 3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Transition-Edge Sensor X-ray Microcalorimeter Linear Array for Compton Scattering and Energy Dispersive Diffraction Imaging

In this paper we present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge sensors with absorbers in strip geometry arranged in a linear array. We discuss the fabrication steps needed to develop this array including Mo/Cu bilayer, Au electroplating, and proofof-principle fabrication of long strips of SiNx membranes. We demonstrate minimal unwanted effect of strip geometry on X-ray pulse response and showlinear relationship of 1/pulse height and pulse decay times with absorber length. For the absorber lengths studied, our preliminary measurements show energy resolutions of 40-180eV near 17 keV. Furthermore, we show that the heat flow to the cold bath is nearly independent of the absorber area and depends on the SiNx membrane geometry.

47 OTHER INSTRUMENTATION↗

Radiofrequency Ablation of Large Renal Angiomyolipoma: Median-Term Follow-Up

Purpose. To study the feasibility of percutaneous radiofrequency ablation (RFA) of large angiomyolipomas (AMLs) using saline-cooled electrodes. Materials and Methods. Institutional Review Board approval for the study was received. Four patients (all female, age range 33-67 years) with large AMLs (maximal axis 6.1-32.4 cm) not suitable for embolotherapy or surgery consented to a trial of RFA. Procedures were performed under computerized tomographic guidance using 14G saline-infused electrodes. Two ablations (diameter 4-7 cm) were undertaken in each patient. Variables studied were technical success, treatment safety, alteration of tumor consistency, tumor size, effect on renal function, and medium-term freedom from haemorrhage. Results. All four patients underwent successful RFA without any intraprocedural complications. There has been no haemorrhage, or new renal specific symptom, during a minimum 48-month period, and normal renal function has been normal. On follow-up radiological imaging, the tumors have become fattier with involution of the soft-tissue elements (soft tissue-to-total tumor ratio decreased mean [range] of 0.26 [0.14-0.48] to 0.17 [0.04-0.34] U; p = 0.04 [paired Student t test]). Further evidence of treatment effect was the development of a capsule around the ablation zone, but there was no change in overall tumor volume (mean [range] 1,120 [118-2,845] to 1150 [90-3,013] ml; p = 1 [paired Student t test]). Conclusion. RFA of large AMLs is technically feasible using saline-infused electrodes. The soft-tissue elements decreased in volume; the tumors become fattier; and there has been no renal haemorrhage during a 48-month period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗