Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective modulation of electronic transport in VO 2 induced by 10 keV helium ion irradiation

Vanadium dioxide (VO 2 ) manifests an abrupt metal–insulator transition (MIT) from monoclinic to rutile phases, with potential use for tunable electronic and optical properties and spiking neuromorphic devices. Understanding pathways to modulate electronic transport in VO 2 , as well as its response to irradiation (e.g., for space applications), is critical to better enable these applications. In this work, we investigate the selective modulation of electronic transport in VO 2 films subject to different 10 keV helium ion (He + ) fluences. Under these conditions, the resistivity in the individual monoclinic and rutile phases varied by 50%–200%, while the MIT transformation temperature remains constant within 4 °C independent of irradiation fluence. Importantly, different trends in the resistivity of the monoclinic and rutile phases were observed both as a function of total He fluence as well as in films grown on different substrates (amorphous SiO 2 /Si vs single crystal Al 2 O 3 ). Through a combination of measurements including majority carrier sign via Seebeck, low frequency noise, and TEM, our investigation supports the presence of different kinds of point defects (V in; O in), which may arise due to grain boundary defect interactions. Our work suggests the utility of He irradiation for the selective modulation of VO 2 transport properties for neuromorphic, in contrast to other established but non-selective methods, like doping.

36 MATERIALS SCIENCE↗

ABC -Auxetics: An Implicit Design Approach for Negative Poisson's Ratio Materials

A novel methodology is introduced for designing auxetic (negative Poisson's ratio) structures based on topological principles and is demonstrated by investigating a new class of auxetics based on two-dimensional (2D) textile weave patterns. Conventional methodology for designing auxetic materials typically involves determining a single deformable block (a unit cell) of material whose shape results in auxetic behavior. Consequently, patterning such a unit cell in a 2D (or 3D) domain results in a larger structure that exhibits overall auxetic behavior. Such an approach naturally relies on some prior intuition and experience regarding which unit cells may be auxetic. Second, tuning the properties of the resulting structures is typically limited to parametric variations of the geometry of a specific type of unit cell. Thus, most of the currently known auxetic structures belong to a selected few classes of unit cell geometries that are explicitly defined in accordance with a specified topological (i.e., grid structure). Herein, a new class of auxetic structures is demonstrated that, while periodic, can be generated implicitly, i.e., without reference to a specific unit cell design. The approach leverages weave-based parameters (A–B–C), resulting in a rich design space for auxetics that is previously unexplored.

36 MATERIALS SCIENCE↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation

Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanistic origins of corrosion protection of aluminum alloys by graphene/polyetherimide nanocomposite coatings

Light-weighting vehicular components through adoption of light-metal structural alloys holds promise for reducing the fuel consumption of internal combustion engine vehicles and increasing the range of battery electric vehicles. However, the alloyed microstructure and surface precipitates of aluminum alloys render these materials susceptible to corrosion under modest excursions from neutral pH. Traditional chromium-based anodic passivation layers are subject to increasingly stringent environmental regulations, whereas options for sacrificial cathodic films are sparse for electropositive metals. While hybrid nanocomposite coatings have shown initial promise, mechanistic underpinnings remain poorly understood. Here, a fully imidized polyetherimide (PEI) resin is utilized as the continuous phase with inclusion of unfunctionalized exfoliated graphite (UFG). A comprehensive investigation of the mechanisms of corrosion protection reveals key fundamental design principles underpinning corrosion inhibition. First, strong interfacial adhesion, which for PEI is facilitated by binding of imide carbonyl moieties to Lewis acidic sites on Al surfaces. Second, the miscibility of ion-impervious nanoscopic UFG fillers and stabilization of a substantial interphase region at UFG/PEI boundaries that result in minimizing the free volume at the filler/polymer interface. Finally, extended tortuosity of ion diffusion pathways imbued by the below-percolation-threshold 2D fillers. These three design principles help govern and modulate ion transport from electrolyte/coating interfaces to the coating/metal interface and are crucial for the extended preservation of barrier properties. The results suggest an approach to systematically activate multiple modes of corrosion inhibition through rational design of hybrid nanocomposite coatings across hard-to-abate sectors where light metal alloys are likely to play an increasingly prominent role.

36 MATERIALS SCIENCE↗

A reference-area-free strain mapping method using precession electron diffraction data

Here, in this work, we developed a method using precession electron diffraction data to map the residual elastic strain at the nano-scale. The diffraction pattern of each pixel was first collected and denoised. Template matching was then applied using the center spot as the mask to identify the positions of the diffraction disks. Statistics of distances between the selected diffracted disks enable the user to make an informed decision on the reference and to generate strain maps. Strain mapping on an unstrained single crystal sapphire shows the standard deviation of strain measurement is 0.5%. With this method, we were able to successfully measure and map the residual elastic strain in VO 2 on sapphire and martensite in a Ni 50.3 Ti 29.7 Hf 20 shape memory alloy. This approach does not require the user to select a “strain-free area” as a reference and can work on datasets even with the crystals oriented away from zone axes. This method is expected to provide a robust and more accessible alternative means of studying the residual strain of various material systems that complements the existing algorithms for strain mapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

Cation reordering instead of phase transitions: Origins and implications of contrasting lithiation mechanisms in 1D ζ- and 2D α-V 2 O 5

Substantial improvements in cycle life, rate performance, accessible voltage, and reversible capacity are required to realize the promise of Li-ion batteries in full measure. Here, we have examined insertion electrodes of the same composition (V 2 O 5 ) prepared according to the same electrode specifications and comprising particles with similar dimensions and geometries that differ only in terms of their atomic connectivity and crystal structure, specifically two-dimensional (2D) layered α-V 2 O 5 that crystallizes in an orthorhombic space group and one-dimensional (1D) tunnel-structured ζ-V 2 O 5 crystallized in a monoclinic space group. By using particles of similar dimensions, we have disentangled the role of specific structural motifs and atomistic diffusion pathways in affecting electrochemical performance by mapping the dynamical evolution of lithiation-induced structural modifications using ex situ scanning transmission X-ray microscopy, operando synchrotron X-ray diffraction measurements, and phase-field modeling. We find the operation of sharply divergent mechanisms to accommodate increasing concentrations of Li-ions: a series of distortive phase transformations that result in puckering and expansion of interlayer spacing in layered α-V 2 O 5 , as compared with cation reordering along interstitial sites in tunnel-structured ζ-V 2 O 5 . By alleviating distortive phase transformations, the ζ-V 2 O 5 cathode shows reduced voltage hysteresis, increased Li-ion diffusivity, alleviation of stress gradients, and improved capacity retention. The findings demonstrate that alternative lithiation mechanisms can be accessed in metastable compounds by dint of their reconfigured atomic connectivity and can unlock substantially improved electrochemical performance not accessible in the thermodynamically stable phase.

25 ENERGY STORAGE↗