Search NASA⌕ Search

Engineering topics

Pianetta, P

Publications and source records attributed to Pianetta, P.

Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL

State-of-the-art hard x-ray full-field transmission x-ray microscopy (TXM) at beamline 6-2C of Stanford Synchrotron Radiation Lightsource has been applied to various research fields including biological, environmental, and material studies. With the capability of imaging a 32-micron field-of-view at 30-nm resolution using both absorption mode and Zernike phase contrast, the 3D morphology of yeast cells grown in gold-rich media was investigated. Quantitative evaluation of the absorption coefficient was performed for mercury nanoparticles in alfalfa roots exposed to mercury. Combining XANES and TXM, we also performed XANES-imaging on an ancient pottery sample from the Roman pottery workshop at LaGraufesenque (Aveyron).

60 APPLIED LIFE SCIENCES↗

The Surface Activation Layer of GaAs Negative Electron Affinity Photocathode Activated by Cs, Li and NF3

The lifetime of GaAs photocathodes can be greatly improved by introducing Li in the Cs+NF{sub 3} activation process. The surface activation layer of such photocathodes is studied by synchrotron radiation photoemission and is compared with GaAs photocathodes activated without Li. The charge distributions of N, F and Cs experience significant changes when Li is added in the activation. In addition, the presence of Li causes NF{sub x} molecules to take an orientation with F atoms on top. All these changes induced by Li hold the key for the lifetime improvement of GaAs photocathodes.

43 PARTICLE ACCELERATORS↗

Evaluation of Electron Energy Spread in CsBr Based Photocathodes

Photocathodes with relatively low energy spread (<0.5 eV) are required for electron sources in several applications including single and multiple electron beam inspection and lithography tools and free electron lasers. CsBr based photocathodes have been shown to be very robust and capable of operation at high current density (>150 A/cm{sup 2}) with very long lifetime (approximately hundreds of hours/spot). Experimental results of the photoelectron energy spread obtained in CsBr films deposited on both metal and InGaN substrates will be presented in this paper.

36 MATERIALS SCIENCE↗

CsBr/GaN Heterojunction Photoelectron Source

Experimental results on a new CsBr/GaN heterojunction photocathode structure are presented. The results indicate a fourfold improvement in photoyield relative to CsBr/Cr photocathodes. A model is presented based on intraband states in CsBr and electron injection from the GaN (with 1% addition of indium) substrate to explain the observed photoyield enhancement. The photocathode lifetime at high current density (>40 A/cm{sup 2}) is limited by laser heating of the small illuminated area. Calculations are presented for sapphire and diamond substrates, indicating a factor of 20 reduction in temperature for the latter. The results are encouraging for the realization of a high photoyield photocathode operating at high current density with long lifetime.

36 MATERIALS SCIENCE↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synchrotron Radiation Photoemission Spectroscopic Study of Band Offsets and Interface Self-cleaning by Atomic Layer Deposited HfO2 on In0.53Ga0.47As and In0.52Al0.48As

The Synchrotron Radiation Photoemission Spectroscopic (SRPES) study was conducted to (a) investigate the surface chemistry of In{sub 0.53}Ga{sub 0.47}As and In{sub 0.52}Al{sub 0.48}As post chemical and thermal treatments, (b) construct band diagram and (c) investigate the interface property of HfO{sub 2}/In{sub 0.53}Ga{sub 0.47}As and HfO{sub 2}/In{sub 0.52}Al{sub 0.48}As. Dilute HCl and HF etch remove native oxides on In{sub 0.53}Ga{sub 0.47}As and In{sub 0.52}Al{sub 0.47}As, whereas in-situ vacuum annealing removes surface arsenic pile-up. After the atomic layer deposition of HfO{sub 2}, native oxides were considerably reduced compared to that in as-received epi-layers, strongly suggesting the self-clean mechanism. Valence and conduction band offsets are measured to be 3.37 {+-} 0.1eV, 1.80 {+-} 0.3eV for In{sub 0.53}Ga{sub 0.47}As and 3.00 {+-} 0.1eV, 1.47 {+-} 0.3eV for In{sub 0.52}Al{sub 0.47}As, respectively.

43 PARTICLE ACCELERATORS↗

Arsenic-Dominated Chemistry in the Acid Cleaning of InGaAs and InAlAs Surfaces

The surface cleaning of InGaAs and InAlAs is studied using Synchrotron Radiation Photoelectron Spectroscopy. Thermal annealing at 400 C can not completely remove the native oxides from those surfaces. Elemental arsenic build-up is observed on both surfaces after acid treatment using HCl, HF or H{sub 2}SO{sub 4} solutions, which is similar to acid-cleaned GaAs surface. Cleaned InGaAs surface is oxide free but small amount of aluminum oxide remains on cleaned InAlAs surface. The common chemical reactions between III-As semiconductors and acid solutions are identified and are found to be dominated by arsenic chemistry.

43 PARTICLE ACCELERATORS↗

MICROSCANNING XRF, XANES, AND XRD STUDIES OF THEDECORATED SURFACE OF ROMAN TERRA SIGILLATA CERAMICS

Different microscanning synchrotron techniques were used to better understand the elaboration process and origins of Terra Sigillata potteries from the Roman period. A mixture Gallic slip sample cross-section showing red and yellow colors was studied. The small (micron) size of the X-ray beam available at Stanford Synchrotron Radiation Laboratory (SSRL) and Advanced Light Source (ALS) synchrotron sources, coupled with the use of a sample scanning stage allowed us to spatially resolve the distribution of the constitutive mineral phases related to the chemical composition. Results show that red color is a result of iron-rich hematite crystals and the yellow part is a result of the presence of Ti-rich rutile-type phase (brookite). Volcanic-type clay is at the origin of these marble Terra Sigillata.

36 MATERIALS SCIENCE↗

The Effectiveness of HCl and HF Cleaning of Si0.85Ge0.15 Surface

The cleaning of Si{sub 0.85}Ge{sub 0.15} surfaces using HCl and HF solutions is studied using synchrotron radiation photoelectron spectroscopy. The HF solution is found to be effective in removing both the Si oxide and the Ge oxide while the HCl solution can only remove part of the Ge oxide. For samples treated with HF, four spectral components are needed to fit the Ge 3d photoemission spectra. One is the bulk component and the other three are attributed to the surface Ge atoms with mono-hydride, di-hydride and tri-hydride terminations, respectively.

43 PARTICLE ACCELERATORS↗

Photoemission Study of Cs-NF3 Activated GaAs(100) Negative Electron Affinity Photocathodes

GaAs based negative electron affinity photocathodes activated with Cs and NF{sub 3} are used as polarized electron sources for linear accelerators. It is generally believed that the activation layer consists of CsF. The activation layers of Cs-NF{sub 3} on GaAs photocathodes are herein investigated using synchrotron radiation photoelectron spectroscopy (SR-PES). F1s, N1s and other core levels are recorded at photon energies ranging from 70eV to 820eV. Surprisingly, a significant amount of nitrogen is observed in the activation layers. Two distinct species of nitrogen are observed, one of which decreases along with the Fluorine signal as the yield of the photocathode decays with time.

43 PARTICLE ACCELERATORS↗