Search NASA⌕ Search

Engineering topics

Poirier, Michael R.

Publications and source records attributed to Poirier, Michael R..

At least 19 records

Methods of separating materials by use of a centrifugal contactor

Centrifugal contactors that can be used for mixing or separating materials are described. The contactors include a sensing system including a communications fiber within the shaft of the contactors and access ports providing access from the communications fiber to the mixing/separating zone of the contactor. The sensing system can be utilized during operation of the contactor and can provide for detailed and accurate on-line characterization of a protocol, as well as process control and system modification as necessary during operation.

Restivo, Michael L.↗

M-Star ® Software Test and Verification

Savannah River Mission Completion (SRMC) currently manages the risk for retained hydrogen in the Defense Waste Processing Facility (DWPF) vessels by implementing a Retained Hydrogen Program. The current program relies on Sludge Batch (SB) 8 Gas Chromatograph data and on conservative assumptions concerning gas release and retention to determine allowable vessel Quiescent time (Q-time). The authors identified M-Star ® CFD as a software that could simulate processes such as fluid flow, heat transfer, species transport, chemical reactions, particle transport, and retained hydrogen gas release. Preliminary simulation results suggest that more realistic assumptions on gas retention and release may be feasible for the DWPF retained hydrogen program. Because of the desire to use the M-Star ® software to perform analyses that support nuclear safety, SRMC has requested Savannah River National Laboratory (SRNL) to upgrade the software classification level of M-Star ® CFD from level D to level A to perform analyses that support nuclear safety.

08 HYDROGEN↗

Mixing Study for the Modification of H-Canyon Tank 31 and 32 Recirculation Lines Via M-Star®

As a part of the Accelerated Basin De-Inventory (ABD) program Tanks 31 or 32 will be re-purposed to support increasing the number of annual Material Test Reactor (MTR) and High Flux Isotope Reactor (HFIR) dissolutions. The proposed plan will allow Tanks 31 or 32 to be used as the dissolver cold chemical solution makeup tank and storage tank. The dissolver cold chemicals are 50% nitric acid, process water, mercuric nitrate, and gadolinium nitrate. Tanks 31 and 32 are 9 ft. (outer diameter) x 36 ft, horizontal, and can hold approximately 56,000 liters (15,000 gallons) each. One full volume of Tanks 31 or 32 can support 4 HFIR 6.4D equivalent batches. Both tanks are equipped with liquid level instrumentation. Tank 31 is equipped with 1 pump used for transfer and recirculation while Tank 32 is equipped with two pumps, one for transfer and the other for recirculation. Each of the pumps is equipped with sample taps. The tanks do not have specific gravity instrumentation, an agitator, or a sampler. Piping modifications will also be performed to supply the tank with cold chemicals. The current dissolver chemical composition is 5.0 -8.5M HNO3 and ~0.2 g Gd/L. The recirculating pump connected to Tank 31 is rated for a flowrate 175 gpm while the pump connected to Tank 32 is rated for a flowrate 50 gpm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Centrifugal contactor including central dynamic examination device

Centrifugal contactors that can be used for mixing or separating materials are described. The contactors include a sensing system including a communications fiber within the shaft of the contactors and access ports providing access from the communications fiber to the mixing/separating zone of the contactor. The sensing system can be utilized during operation of the contactor and can provide for detailed and accurate on-line characterization of a protocol, as well as process control and system modification as necessary during operation.

Restivo, Michael L.↗

Tank 27 Solids Disturbance Testing Using M-Star for the Impact of CSMP Usage on Blend Tank Mixing Effectiveness

Savannah River Mission Completion (SRMC) plans to operate Tank 27as a blend tank for future waste disposal operations. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches above the tank floor. The CSMPs shall maintain adequate blending within a 24 hour maximum timeframe and an adequate nozzle discharge velocity as outlined in U-ESR-G-00030, using the specifications of the planned CSMPs listed in PO SRRA149971 and M-DS-G-00081. Specifications include: maximum pump diameter of D=22.5 in., dual nozzles placed tangentially opposed with nominal inside diameter of 2 in., total flow range (both nozzles combined) of 500 to 1950 GPM and maximum RPM of 1800. Tank 27 is expected to have a fill height maximum of 360". This analysis began by using results from the 2010 testing and applying them to the Tank 27 design to calculate a mixing time as a function of pump flow rate. These results were modified to account for the higher liquid level in Tank 27. Once the liquid level was increased to 360 inches, the results were modified to account for a higher viscosity in Tank 27 than in the testing. Once the viscosity was increased, the effect of changing pump elevation was applied to calculations of the mixing time in Tank 27. Finally, the uncertainty from the testing was included in the analysis to recommend a blend time as a function of pump flow rate and elevation. The conclusion from this study is that the particles in tank 27 will be suspended at both the 600 and 900 gpm flow rates. Only particles above 90 micron will not be suspended in significant amounts when the flow rate is 600 gpm. At 900 gpm even 100 micron particles were thoroughly suspended in the tank. From the series of simulations it has been concluded that it will not be possible to mix tank 27 at the proposed fluid flow rates and not suspend the solid particles at the bottom of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blend Pump Mixing in Tank 27 Evaluation

For future waste disposal operations, Savannah River Mission Completion (SRMC) plans to operate Tank 27 as a blend tank. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches. Specifications include: A maximum pump diameter of 22.5 inches, dual nozzles placed tangentially opposed with nominal inside diameter of 2 inches, a total flow range (both nozzles combined) of 500 to 1950 gallons per minute (gpm) and a maximum revolutions per minute (RPM) of 1800. Tank 27 is expected to have maximum fill height of 360 inches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

M-Star ® Modeling of SME Mixing with Three Impeller Blades

Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable. To evaluate mixing in the SME with a broken agitator containing only three blades (90 degrees apart with space for a missing blade) on the bottom impeller, the Savannah River National Laboratory (SRNL) was requested to perform computer simulations of impeller mixing in the SME using M-Star ® software. The simulations will be used to determine if SME Batch 804 was well mixed and satisfies homogeneity requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

M-Star® Software Test and Verification for Impeller Mixing in a Tank

Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling gas release from a Bingham plastic slurry and deconvoluting measured data

Physics-based models for predicting the off-gassing characteristics of agitated slurries are presented. This approach decomposes the system into two separate but coupled slurry and headspace models. The physics driving bubble transport through the slurry and gas mixing within the headspace are discussed. An analytical expression for predicting the time evolution of the headspace concentration using first principles theory is also presented. Predictions from the numerical models, as well as expectations from the analytical solution, both agree with measured off gassing data for two different experimental operating conditions. After benchmarking the numerical model predictions against experimental data, the model was used to make predictions for gas release from a full-scale vessel and to perform sensitivity analyses to examine the sensitivity of gas release to parameters such as yield stress, consistency index, slurry density, bubble size, bubble concentration, and impeller speed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tank 49H solids disturbance analysis

Tank 49H serves as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb any solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L of the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer could potentially disturb any solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine whether accounting for disturbed particle settling and particle mixing and dispersion during transfer could allow the minimum liquid level to be reduced below 120 inches. The analysis utilized models from the technical literature to calculate the size and shape of the “plunging jet” as a function of input parameters such as initial velocity, initial jet diameter, elevation of the initial jet, liquid level in the tank, and solids depth. The analysis relied on the M-Star® simulations performed for the previous analysis to provide bounding estimates of the amount of solid particles disturbed and used the MStar® software to calculate the dispersion and mixing of the disturbed solids with other liquid in the tank as the solids are transported to the transfer pump. The analysis showed that with a solid particle size of 5 micron or less, a liquid level of 120 inches should be maintained to prevent significant disturbance of the solid layer at the bottom of Tank 49H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling DWPF Hydrogen Gas Retention and Release

Savannah River Remediation (SRR) currently manages the risk for retained hydrogen in the Defense Waste Processing Facility (DWPF) vessels by implementing a Retained Hydrogen Program. The current program conservatively relies on bounding assumptions concerning gas release and retention to develop allowable vessel Q-times. SRR would like to establish more realistic inputs to the Retained Hydrogen Program. To address this need, SRNL conducted a literature search on work investigating the retention and release of gas from DWPF type slurries. The search revealed that the retained hydrogen is not released instantaneously upon the start of agitation, and that hydrogen gas could be released under quiescent, non-agitated, conditions. The literature search also identified a Lattice-Boltzmann computational fluid dynamics (CFD) software that could model and predict hydrogen release from DWPF vessels. SRR requested that Savannah River National Laboratory (SRNL) personnel pursue this software and focus the model for hydrogen gas retention and release to justify relaxing these conservative assumptions. This report documents the refinement of the CFD software model and application to show its ability to describe retained hydrogen release from DWPF vessels and relax the conservativisms in the Retained Hydrogen Program.

08 HYDROGEN↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls from the Tank 49H B4 downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. The scope of this task is to perform fluid flow analysis to determine the impact of a “plunging jet” through the B4 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF.

54 ENVIRONMENTAL SCIENCES↗

Tank 50H Mixing Pump Run Time Reassessment

Tank 50H is required to operate a single rotating standard slurry pump for 4.5 hours prior to transfers to the Salt Solution Receipt Tanks (SSRTs) in the Saltstone Production Facility (SPF). This mixing time is required to adequately mix miscible and immiscible liquids within Tank 50H and meet the Saltstone Waste Acceptance Criteria (WAC). The miscible liquids are aqueous solutions of dissolved salts, while the immiscible liquids include organic droplets such as Isopar® L. To support the accelerated salt processing rates from the Salt Waste Processing Facility (SWPF), a desire to reduce the transfer time of Decontaminated Salt Solution (DSS) downstream of SWPF was identified. This document describes the analysis performed to reassess the technical basis for the 4.5 hour mixing requirement for Tank 50H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the SRNL Studies of the MCU Strip Effluent Coalescers

Three potential causes of the strip effluent (SE) coalescer (SEC) failure were investigated: inorganic fouling, organic fouling, and biological fouling. From the analysis of the SEC and leachate samples from the SEC, there is no evidence that the fouling is caused by inorganic precipitates, solids, or salts. The analysis of the SEC shows the presence of organic material such as sec-butylphenol and Modifier (1-(2,2,3,3-Tetrafluoropropoxy)-3-(4-secbutylphenoxy)-2- propanol). The source of the sec-butylphenol would be from the decomposition of the Modifier in the solvent. The analysis of the SEC shows the presence of amide bonds that are likely from bacteria and other biological material. In addition, samples from the Strip Feed Tank (StFT) and the boric acid delivery tanker showed the presence of bacteria and other biological material. The most likely cause of the SEC fouling is biofouling by bacteria and other organisms that form a biofilm on the SEC fibers. The biofilm would sorb organic material in the feed to the SEC, and not readily release this material. The bacteria would use this trapped organic material to grow the biofilm, which would decrease the porosity of the SEC. The biofilm would thereby impede SEC operation through biofouling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of performing an MST strike in Tank 21H

Previous Savannah River National Laboratory (SRNL) tank mixing studies performed for the Small Column Ion Exchange (SCIX) project have shown that 3 Submersible Mixer Pumps (SMPs) installed in Tank 41 are sufficient to support actinide removal by MST sorption as well as subsequent resuspension and removal of settled solids. Savannah River Remediation (SRR) is pursuing MST addition into Tank 21 as part of the Large Tank Strike (LTS) project. The preliminary scope for LTS involves the use of three standard slurry pumps (installed in N, SE, and SW risers) in a Type IV tank. Due to the differences in tank size, internal interferences, and pump design, a separate mixing evaluation is required to determine if the proposed configuration will allow for MST suspension and strontium and actinide sorption. The author performed the analysis by reviewing drawings for Tank 21 [W231023] and determining the required cleaning radius or zone of influence for the pumps. This requirement was compared with previous pilot-scale MST suspension data collected for SCIX that determined the cleaning radius, or zone of influence, as a function of pump operating parameters. The author also reviewed a previous Tank 50 mixing analysis that examined the ability of standard slurry pumps to suspend sludge particles. Based on a review of the pilot-scale SCIX mixing tests and Tank 50 pump operating experience, three standard slurry pumps should be able to suspend sludge and MST to effectively sorb strontium and actinides onto the MST. Using the SCIX data requires an assumption about the impact of cooling coils on slurry pump mixing. The basis for this assumption is described in this report. Using the Tank 50 operating experience shows three standard slurry pumps should be able to suspend solids if the shear strength of the settled solids is less than 160 Pa. Because Tank 21 does not contain cooling coils, the shear strength could be larger.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blending of Radioactive Salt Solutions in Million Gallon Tanks - 13002

Research was completed at Savannah River National Laboratory (SRNL) to investigate processes related to the blending of radioactive, liquid waste, salt solutions in 4920 cubic meter, 25.9 meter diameter storage tanks. One process was the blending of large salt solution batches (up to 1135 - 3028 cubic meters), using submerged centrifugal pumps. A second process was the disturbance of a settled layer of solids, or sludge, on the tank bottom. And a third investigated process was the settling rate of sludge solids if suspended into slurries by the blending pump. To investigate these processes, experiments, CFD models (computational fluid dynamics), and theory were applied. Experiments were performed using simulated, non-radioactive, salt solutions referred to as supernates, and a layer of settled solids referred to as sludge. Blending experiments were performed in a 2.44 meter diameter pilot scale tank, and flow rate measurements and settling tests were performed at both pilot scale and full scale. A summary of the research is presented here to demonstrate the adage that, 'One good experiment fixes a lot of good theory'. Experimental testing was required to benchmark CFD models, or the models would have been incorrectly used. In fact, CFD safety factors were established by this research to predict full-scale blending performance. CFD models were used to determine pump design requirements, predict blending times, and cut costs several million dollars by reducing the number of required blending pumps. This research contributed to DOE missions to permanently close the remaining 47 of 51 SRS waste storage tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗