DOE OSTI · 1908981
M-Star® Software Test and Verification for Impeller Mixing in a Tank
Abstract
Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Poirier, Michael R., Noble, Sean R.. 2022-11-01. M-Star® Software Test and Verification for Impeller Mixing in a Tank. https://doi.org/10.2172/1908981