Search NASA⌕ Search

Engineering topics

Polsky, Ronen

Publications and source records attributed to Polsky, Ronen.

At least 19 records

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗

Coaxial microneedle assemblies and methods thereof

The present invention is directed to devices including one or more hollow needles and a transducing wire disposed within at least one needle. In particular instances, arrays of such needles can be employed. Methods for fabricating and using such devices are also disclosed herein.

Miller, Philip Rocco↗

Biocompatible Electrostatic Layered Systems for Viral Elimination in the Nose/Throat

An anti-viral coating for the nose & throat is needed to quickly address the spread of COVID-19 infections and to aid future pandemics. Current nasal delivery systems are typically a 1-spray homogenous solution, which is convenient but may not be as efficient or durable as a multi-spray solution that contains a binding layer to anchor the anti-viral components. Many of the current nasal solutions being investigated to aid in pandemic response have solution-based mechanisms of action and are quickly cleared from the nose/mouth limiting their efficacy lifetime. A multi-spray approach utilizing strong intermolecular forces between polymeric materials and anti-viral agents to provide a robust biocompatible coating is expected to have increased physical and chemical properties to combat viral infection. This work evaluated which tailored biocompatible materials are needed to generate a layered system to combat viral infection. This layered system takes advantage of electrostatic interactions to bind anti-viral components, shown in Figure 1. Proof of concept success was demonstrated through cell toxicity studies and anti-viral assays on both the individual layer components and the complete layered system. Project work began with chemical modifications of Xantham Gum to hydrolyzing xanthan gum to give a negatively charged polymer with varying degrees of ionic character and investigate bonding efficiencies. However, this was abandoned in favor of comparing COTS available materials listed in Table 1 (Results section). Concentration and adhesion studies were performed on layers created using the listed polymeric materials and anti-viral agents. Finally, biocompatibility of materials, layers, and coating system were confirmed through cytotoxicity studies and the efficacy of the anti-viral properties tested with phi6 bacteriophage as a SARS-CoV2 surrogate.

36 MATERIALS SCIENCE↗

Microneedle-based electrical impedance sensor to monitor plant water status in real time

A sensor uses microneedle electrodes and multi-frequency electrical impedance spectroscopy to monitor plant water status in real time. The microneedle can be between 10 and 1000 microns in length, enabling precise placement in a variety of plant tissues. The impedance behavior can distinguish electrical properties and physiological functions of different plant tissue types. Therefore, impedance measurements can be used to monitor water stress to prevent irreversible damage to a plant and to enable improvement of plant biomass or fruit yield.

Hanson, David T.↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

COVID-19 LDRD Project Summaries

Sandia National Laboratories currently has 27 COVID-related Laboratory Directed Research & Development (LDRD) projects focused on helping the nation during the pandemic. These LDRD projects cross many disciplines including bioscience, computing & information sciences, engineering science, materials science, nanodevices & microsystems, and radiation effects & high energy density science.

36 MATERIALS SCIENCE↗

Imaging effectiveness calculator for non-design microscope samples

When attempting to integrate single-molecule fluorescence microscopy with microfabricated devices such as microfluidic channels, fabrication constraints may prevent using traditional coverslips. Instead, the fabricated devices may require imaging through material with a different thickness or index of refraction. Altering either can easily reduce the quality of the image formation (measured by the Strehl ratio) by a factor of 2 or more, reducing the signal-to-noise ratio accordingly. In such cases, successful detection of single-molecule fluorescence may prove difficult or impossible. Furthermore, we provide software to calculate the effect of non-design materials upon the Strehl ratio or ensquared energy and explore the impact of common materials used in microfabrication.

47 OTHER INSTRUMENTATION↗

Microneedle arrays for biosensing and drug delivery

Methods, structures, and systems are disclosed for biosensing and drug delivery techniques. In one aspect, a device for detecting an analyte and/or releasing a biochemical into a biological fluid can include an array of hollowed needles, in which each needle includes a protruded needle structure including an exterior wall forming a hollow interior and an opening at a terminal end of the protruded needle structure that exposes the hollow interior, and a probe inside the exterior wall to interact with one or more chemical or biological substances that come in contact with the probe via the opening to produce a probe sensing signal, and an array of wires that are coupled to probes of the array of hollowed needles, respectively, each wire being electrically conductive to transmit the probe sensing signal produced by a respective probe.

47 OTHER INSTRUMENTATION↗

Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles

Dermal interstitial fluid (ISF) is an underutilized information-rich biofluid potentially useful in health status monitoring applications whose contents remain challenging to characterize. Here, we present a facile microneedle approach for dermal ISF extraction with minimal pain and no blistering for human subjects and rats. Extracted ISF volumes were sufficient for determining transcriptome, and proteome signatures. We noted similar profiles in ISF, serum, and plasma samples, suggesting that ISF can be a proxy for direct blood sampling. Dynamic changes in RNA-seq were recorded in ISF from induced hypoxia conditions. Finally, we report the first isolation and characterization, to our knowledge, of exosomes from dermal ISF. The ISF exosome concentration is 12–13 times more enriched when compared to plasma and serum and represents a previously unexplored biofluid for exosome isolation. This minimally invasive extraction approach can enable mechanistic studies of ISF and demonstrates the potential of ISF for real-time health monitoring applications.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostic/drug delivery "sense-respond" devices, systems, and uses thereof

The present invention is directed to devices, systems, and methods for detecting and/or monitoring one or more markers in a sample. In particular, such devices integrate a plurality of hollow needles configured to extract or obtain a fluid sample from a subject, as well as transducers to detect a marker of interest.

47 OTHER INSTRUMENTATION↗

Patterned structures of graphene and graphitic carbon and methods for their manufacture

A patterned graphene or graphitic body is produced by providing a three-dimensionally patterned carbonaceous body; coating the body with a catalytic metal whereby is formed a coating having an inner surface proximal the body and an outer surface distal the body; and annealing the coated body under time and temperature conditions effective to form a graphene or graphitic layer on the outer surface of the catalytic metal coating.

36 MATERIALS SCIENCE↗