Search NASA⌕ Search

Engineering topics

Ray, E. J.

Publications and source records attributed to Ray, E. J..

At least 19 records

Sidewall boundary-layer removal effects on wall adaptation in the Langley 0.3-meter transonic cryogenic tunnel

This paper describes the Langley 0.3-m transonic cryogenic tunnel sidewall boundary-layer removal system and is integrated operation with the adaptive wall adjustment. Empty test section measurements show the sidewall boundary-layer displacement thickness at the model station is reduced from about 1.0 to 0.6 percent of the test section width when the maximum boundary-layer removal conditions are applied. Tests with a supercritical airfoil model show the iterative top and bottom wall adaptation process performs satisfactorily with sidewall boundary-layer removal.

Murthy, A. V.↗

A description of the active and passive sidewall-boundary-layer removal systems of the 0.3-meter transonic cryogenic tunnel

Results are presented for an operational checkout and shakedown of the active sidewall-boundary-layer removal system newly installed in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT). Prior to the installation of this active removal system, the sidewall-boundary layer was removed passively by exhausting directly to the atmosphere (i.e., no reinjection). With the active removal system using the reinjection compressor, the removal capability is greatly expanded to cover the entire operating envelope of the 0.3-m TCT. Details of the active removal system are presented including the compressor reinjection circuit, the compressor pressure ratio/surge control, and the compressor recirculation loop. The control logic and features of the compressor surge control are explained. Initial tests covering critical operating conditions show mass flow removal rates of about 5 percent at lower Mach numbers can be obtained with the active system. Measured performance characteristics of the compressor are presented. As part of the validation of the active system, limited airfoil tests were made using the new system.

Johnson, C. B.↗

Status of advanced airfoil tests in the Langley 0.3-meter transonic cryogenic tunnel

A joint NASA/U.S. industry program to test advanced technology airfoils in the Langley 0.3-meter Transonic Tunnel (TCT) was formulated under the Langley ACEE Project Office. The objectives include providing U.S. industry an opportunity to compare their most advanced airfoils to the latest NASA designs by means of high Reynolds number tests in the same facility. At the same time, industry would again experience in the design and construction of cryogenic test techniques. The status and details of the test program are presented. Typical aerodynamic results obtained, to date, are presented at chord Reynolds number up to 45 x 10(6) and are compared to results from other facilities and theory. Details of a joint agreement between NASA and the Deutsche Forschungs- und Versuchsantalt fur Luft- and Raumfahrt e.V. (DFVLR) for tests of two airfoils are also included. Results of these tests will be made available as soon as practical.

Ladson, C. L.↗

High Reynolds number tests of the cast 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 2

Wind tunnel tests of an advanced technology airfoil, the CAST 10-2/DOA 2, were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). This was the third of a series of tests conducted in a cooperative airfoil research program between the National Aeronautics and Space Administration and the Deutsche Forschungsund Versuchsanstalt fur Luft- und Raumfahrt e. V. For these tests, temperature was varied from 270 K to 110 K at pressures from 1.5 to 5.75 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 2 to 20 million. The aerodynamic data for the 7.62 cm chord airfoil model used in these tests is presented without analysis. Descriptions of the 0.3-m TCT, the airfoil model, the test instrumentation, and the testing procedures are included.

Dress, D. A.↗

High Reynolds number tests of the cast 10-2/DOA2 transonic airfoil at ambient and cryogenic temperature conditions

The transonic airfoil CAST 10-2/DOA2 was investigated in several major transonic wind tunnels at Reynolds numbers ranging from Re=1 million six hundred thousand to forty five million at ambient and cryogenic temperature conditions. The main objective was to study the degree and extent of the effects of Reynolds on both the airfoil aerodynamic characteristics and the interference effects of various model-wind-tunnel systems. the initial analysis of the 10-2 airfoil results revealed appreciable real Reynolds number effects on this airfoil and, moreover, showed that wall interference, can be significantly affected by changes in Reynolds number thus appearing as true Reynolds number effects.

Stanewsky, E.↗

Investigation of sidewall boundary layer removal effects on two different chord airfoil models in the Langley 0.3-meter Transonic Cryogenic Tunnel

An investigation was carried out on two CAST 10-2 airfoil models with chords of 3 in. and 6 in. To evaluate the extent of sidewall influence on airfoil tests at transonic Mach numbers. The tests were conducted in the Langley 0.3-m Transonic Cryogenic Tunnel two-dimensional test section equipped with an upstream sidewall boundary layer removal system which reduces the boundary layer displacement thickness to about 1 percent of model halfspan from an initial 2 percent without boundary layer removal. Test results have shown the changes in the location of the shock on the upper surface of the airfoil to be about the same for both models with and without sidewall boundary layer removal. Even though large differences were noted in the high lift characteristics of the two models, the sidewall boundary layer removal had little effect on the differences. These tests also served to validate the boundary layer removal technique and the associated Mach number correction required with upstream boundary layer removal.

Murthy, A. V.↗

Effect of upstream sidewall boundary layer removal on an airfoil test

Sidewall boundary layer effects were investigated by applying partial upstream sidewall boundary layer removal in the Langley 0.3-m transonic cryogenic tunnel. Over the range of sidewall boundary layer displacement thickness of these tests the influence on pressure distribution was found to be small for subcritical conditions; however, for supercritical conditions the shock position was affected by the sidewall boundary layer. For these tests (with and without boundary layer remove) comparisons with predictions of the GRUMFOIL computer code indicated that Mach number corrections due to the sidewall boundary layer improve the agreement for both subcritical and supercritical conditions. The results also show that sidewall boundary layer removal reduces the magnitude of the sidewall correction; however, a suitable correction must still be made.

Johnson, C. B.↗

High Reynolds number tests of the CAST 10-2/DOA 2 airfoil in the Langley 0.3-meter transonic cryogenic tunnel, phase 1

A wind tunnel investigation of an advanced technology airfoil, the CAST 10-2/DOA 2, was conducted in the Langley 0.3 meter Transonic Cryogenic Tunnel (0.3 m TCT). This was the first of a series of tests conducted in a cooperative National Aeronautics and Space Administration (NASA) and the Deutsche Forschungs- und Versuchsanstalt fur Luft- und Raumfahrt e. V. (DFVLR) airfoil research program. Test temperature was varied from 280 K to 100 K to pressures from slightly above 1 to 5.8 atmospheres. Mach number was varied from 0.60 to 0.80, and the Reynolds number (based on airfoil chord) was varied from 4 x 10 to the 8th power to 45 x 10 to the 6th power. This report presents the experimental aerodynamic data obtained for the airfoil and includes descriptions of the airfoil model, the 0.3 m TCT, the test instrumentation, and the testing procedures.

Dress, D. A.↗

Studies of sidewall boundary layer in the Langley 0.3 meter transonic cryogenic tunnel with and without suction

Boundary layer measurements on the sidewalls of the Langley 0.3 Meter Transonic Cryogenic Tunnel were made to determine the effectiveness of the passive boundary layer bleed system over a Reynolds number range from 20 to 200 x 10 to the sixth power per meter at Mach numbers from 0.30 to 0.76. The tunnel sidewall boundary layer displacement thickness was about 2 percent of the width of the test section without the boundary layer bleed. Measured velocity profiles correlated well with the defect law of Hama. With the boundary layer bleed equivalent to about 2 percent of the test section mass flow, the boundary layer displacement thickness reduced to about 1 percent of the test section width, which is generally considered acceptable for testing airfoils. It was also noticed that effectiveness of the bleed was nearly independent of the Mach number and Reynolds number over the range of conditions tested. A comparison of the measured suction effectiveness of the bleed with the finite difference and integral methods of boundary layer calculation showed good agreement.

Murthy, A. V.↗

Investigation of the effects of upstream sidewall boundary-layer removal on a supercritical airfoil

Sidewall boundary-layer effects have been investigated by applying partial upstream sidewall boundary-layer removal in the Langley 0.3-m Transonic Cryogenic Tunnel. Over the range of sidewall boundary-layer displacement thickness of these tests the influence on pressure distributions was found to be small for subcritical conditions; however, for supercritical conditions the shock position was affected by the sidewall boundary layer. For these tests, with and without boundary-layer removal, comparisons with predictions of the GRUMFOIL computer code indicated that Mach number corrections due to the sidewall boundary layer improves the agreement for both subcritical and supercritical conditions. The results show the necessity for accounting for sidewall effects even when the top and bottom wall effects are small.

Murthy, A. V.↗

A review of Reynolds number studies conducted in the Langley 0.3-m Transonic Cryogenic Tunnel

Initial proof-of-concept results obtained in a pilot transonic tunnel, led to a U.S. decision to apply the cryogenic tunnel concept to the National Transonic Facility (NTF). The pilot tunnel was reclassified as a 'permanent' facility and renamed the 0.3-m Transonic Cryogenic Tunnel (TCT). The 0.3-m TCT, with its ability to operate at temperatures ranging from about 78 K to 340 K, combined with a 6 atmospheres pressure capability, provides extremely high test Reynolds numbers at relatively low model loading. In addition, the ability to vary pressure and temperature independently of Mach number provides a unique capability to conduct studies at a constant dynamic pressure or at a constant Reynolds number with just one model. Attention is given to the simulation of flight conditions, the cryogenic-pressure tunnel concept, the characteristics of the 0.3-m TCT, Reynolds number studies in the three-dimensional test section including a Space Shuttle study, and Reynolds number studies in the two-dimensional test section.

Ray, E. J.↗

High Reynolds number tests of a Boeing BAC I airfoil in the Langley 0.3-meter transonic cryogenic tunnel

A wind tunnel investigation of an advanced-technology airfoil was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT). This investigation represents the first in a series of NASA/U.X. industry two dimensional airfoil studies to be completed in the Advanced Technology Airfoil Test program. Test temperature was varied from ambient to about 100 K at pressures ranging from about 1.2 to 6.0 atm. Mach number was varied from about 0.40 to 0.80. These variables provided a Reynolds number (based on airfoil chord) range from about .0000044 to .00005. This investigation was specifically designed to: (1) test a Boeing advanced airfoil from low to flight-equivalent Reynolds numbers; (2) provide the industry participant (Boeing) with experience in cryogenic wind-tunnel model design and testing techniques; and (3) demonstrate the suitability of the 0.3-m TCT as an airfoil test facility. All the objectives of the cooperative test were met. Data are included which demonstrate the effects of fixed transition, Mach number, and Reynolds number on the aerodynamic characteristics of the airfoil. Also included are remarks on the model design, the model structural integrity, and the overall test experience.

Johnson, W. G., Jr.↗

Recent sidewall boundary-layer investigations with suction in the Langley 0.3-m Transonic Cryogenic Tunnel

An experimental and theoretical study of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) sidewall boundary-layer with and without suction, has been made. Without suction, the boundary-layer displacement thickness at a station ahead of the model varied from about 1.6 mm to 1.3 mm over a Reynolds number range of 20 million to 200 million per m at Mach numbers from 0.30 to 0.76. Measured velocity profiles were correlated using the defect law of Hama. The boundary-layer displacement thickness decreased when suction was applied; however, after suction of about 2 percent of test section mass flow, the change in the thickness was small. A comparison of the measured suction effectiveness with finite difference and integral methods of boundary-layer calculation showed that both methods predicted the right trend over the range of suction velocities (up to a suction to free-stream velocity ratio of -0.02).

Murthy, A. V.↗

Design and construction of 2 transonic airfoil models for tests in the NASA Langley C.3-M TCT

As part of a NASA/DFVLR cooperation program two transonic airfoils were tested in the NASA Langley 0.3-m TCT. Model design and construction was carried out by DFVLR. The models designed and constructed performed extremely well under cryogenic conditions. Essentially no permanent changes in surface quality and geometric dimensions occurred during the tests. The aerodynamic results from the TCT tests which demonstrate the large sensitivity of the airfoil CAST 10-Z/DOAZ to Reynolds number changes compared well with results from other facilities at ambient temperatures.

Schaechterle, G.↗

Review of design and operational characteristics of the 0.3-meter transonic cryogenic tunnel

The past 6 years of operation with the NASA Langley 0.3 m transonic cryogenic tunnel (TCT) show that there are no insurmountable problems associated with cryogenic testing with gaseous nitrogen at transonic Mach numbers. The fundamentals of the concept were validated both analytically and experimentally and the 0.3 m TCT, with its unique Reynolds number capability, was used for a wide variety of aerodynamic tests. Techniques regarding real-gas effects were developed and cryogenic tunnel conditions can be set and maintained accurately. Cryogenic cooling by injecting liquid nitrogen directly into the tunnel circuit imposes no problems with temperature distribution or dynamic response characteristics. Experience with the 0.3 m TCT, indicates that there is a significant learning process associated with cryogenic, high Reynolds number testing. Many of the questions have already been answered; however, factors such as tunnel control, run logic, economics, instrumentation, and model technology present many new and challenging problems.

Ray, E. J.↗

Langley's two-dimensional research facilities: Capabilities and plans

The current capabilities and the forthcoming plans for Langley's two-dimensional research facilities are described. The characteristics of the Langley facilities are discussed in terms of Reynolds number, Mach number, and angle-of-attack capabilities. Comments are made with regard to the approaches which have been investigated to alleviate typical problem areas such as wall boundary effects. Because of the need for increased Reynolds number capability at high subsonic speeds, a considerable portion of the paper deals with a description of the 20 by 60 cm two-dimensional test section of the Langley 0.3 meter transonic cryogenic tunnel which is currently in the calibration and shakedown phase.

Ray, E. J.↗