Search NASA⌕ Search

Engineering topics

Reier, M.

Publications and source records attributed to Reier, M..

Depth Measurements Using Alpha Particles and Upsettable SRAMs

A custom designed SRAM was used to measure the thickness of integrated circuit over layers and the epi-layer thickness using alpha particles and a test SRAM. The over layer consists of oxide, nitride, metal, and junction regions.

upsettable SRAMs↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The design of a source to simulate the gamma-ray spectrum emitted by a radioisotope thermoelectric generator

A simulated source was designed to duplicate the gamma spectrum of a uniform cylindrical 2200-watt Pu02 radioisotope thermoelectric generator containing 81% Pu-238 and 1.2 ppm Pu-236. Gamma rays from the decay of Pu-238, Am-241, Pu-239, and the 0-18(alpha,n)Ne-21 reaction were catalogued in broad energy groups. Two 46- and one 22-mc Th-228 sources provided simulation at various times in the life of the fuel capsule up to 18 years, which covers the time span of an outer planet mission. Emission from Th-228 represents the overwhelming contribution of the gamma spectrum after the first few years. The sources, in the form of 13-inch rods, were placed in a concentric hole in a cylinder of depleted uranium, which provided shielding equivalent to the self-shielding of the fuel capsule. The thickness of the U-238 cylinder (0.55cm) was determined by Monte Carlo calculations to insure that the spectrum emerging from the simulated source matched that of the fuel capsule.

Reier, M.↗