Search NASASearch

Engineering topics

Reinhardt, V. S.

Publications and source records attributed to Reinhardt, V. S..

At least 19 records

Superconducting-Cavity Accelerometer

Resonant frequency of microwave superconducting cavity sensitive to gravitation and acceleration. Sensitive accelerometer assembled by combining superconducting microwave cavity and conventional microwave semiconductor oscillator circuit. Device measures acelerations as small as 10-10 cm/S2 (10-13 g's). Also configured to measure small gradients in gravitational field of Earth.

Reinhardt, V. S.

High stability buffered phase comparator

A low noise RF signal phase comparator comprised of two high stability driver buffer amplifiers driving a double balanced mixer which operate to generate a beat frequency between the two RF input signals coupled to the amplifiers from the RF sources is described. The beat frequency output from the mixer is applied to a low noise zero crossing detector which is the phase difference between the two RF inputs. Temperature stability is provided by mounting the amplifiers and mixer on a common circuit board with the active circuit elements located on one side of a circuit board and the passive circuit elements located on the opposite side. A common heat sink is located adjacent the circuit board. The active circuit elements are embedded into the bores of the heat sink which slows the effect of ambient temperature changes and reduces the temperature gradients between the active circuit elements, thus improving the cancellation of temperature effects. The two amplifiers include individual voltage regulators, which increases RF isolation.

Adams, W. A.

High stability amplifier

An electrical RF signal amplifier for providing high temperature stability and RF isolation and comprised of an integrated circuit voltage regulator, a single transistor, and an integrated circuit operational amplifier mounted on a circuit board such that passive circuit elements are located on side of the circuit board while the active circuit elements are located on the other side is described. The active circuit elements are embedded in a common heat sink so that a common temperature reference is provided for changes in ambient temperature. The single transistor and operational amplifier are connected together to form a feedback amplifier powered from the voltage regulator with transistor implementing primarily the desired signal gain while the operational amplifier implements signal isolation. Further RF isolation is provided by the voltage regulator which inhibits cross-talk from other like amplifiers powered from a common power supply. Input and output terminals consisting of coaxial connectors are located on the sides of a housing in which all the circuit components and heat sink are located.

Adams, W. A.

The NASA/GSFC hydrogen maser program: A review of recent data

Data is presented on the phase and frequency stability, over time periods extending to one week, of the new NR field operable hydrogen masers developed by the Applied Physics Laboratory (APL) and the older NX and NP field operable hydrogen masers developed by Goddard Space Flight Center and maintained and upgraded by Bendix Field Engineering Corporation (BFEC). Data is presented on the NR masers in the laboratory showing frequency stabilities well into the 10 to the -15th power range and phase stabilities well into the 100 ps range for periods of up to one day. Data is presented on upgraded NP masers in the laboratory showing that the frequency stability has been improved substantially to virtually the NR level. VLBI data is presented on the phase difference between NX-2 at Owens Valley, California and NR-2 at Fort Davis, Texas for a one week period showing, after removal of a constant frequency drift, a 350 ps RMS phase stability.

Chiu, M.

Wideband Amplifier With Subpicosecond Stability

RF circuit offers high isolation as well as phase stability. For temperature stability, all circuit components are contained in closed metal housing; packages of active circuit elements are embedded in common heat sink. Provisions not only slow down effect of ambient temperature changes on individual devices but also reduce temperature differences across devices so that differential temperature effects vanish.

Reinhardt, V. S.

Precise Phase Comparator for Nearly Equal Frequencies

New circuit precisely compares phases of two RF signals nearly equal in frequency, such as two hydrogen-maser frequency standards. Measuring circuit minimizes interactions between two sources. Also stabilized against thermal effects and against noise that could produce erroneous readings. Heat sinking, buffer amplifiers, and low-noise zero-crossing detector make picosecond precision possible.

Reinhardt, V. S.

A supersensitive accelerometer for spacecraft gradiometry

An exact knowledge of the earth's gravity field is needed for advanced studies related to solid earth and ocean physics. A study (GRAVSAT-A) is currently considered by NASA to determine the gravity field with an accuracy of 2-3 mgal change and a resolution of 100 km using satellite to satellite range rate tracking techniques. The present investigation has the objective to prepare the foundation of an advanced GRAVSAT-B mission in the 1990s with an accuracy of about 1 mgal and a resolution of about 50 km. It is possible that satellite to satellite tracking will not be able to satisfy these requirements. However, it appears that a new technology, called "high sensitivity gradient gradiometry", could be employed to achieve the aims of the GRAVSAT-B mission. Attention is given to a new type of gravity gradiometer using superconducting microwave cavity oscillator accelerometers.

Reinhardt, V. S.

Recent progress in the NASA-Goddard Space Flight Center atomic hydrogen standards program

At NASA Goddard Space Flight Center and through associated contractors, a broad spectrum of work is being carried out to develop improved hydrogen maser frequency standards for field use, improved experimental hydrogen maser frequency standards, and improved frequency and time distribution and measurement systems for hydrogen maser use. Recent progress in the following areas is reported: results on the Nr masers built by the Applied Physics Laboratory of Johns Hopkins University, the development of a low cost hydrogen maser at Goddard Space Flight Center, and work on a low noise phase comparison system and digitally phase locked crystal oscillator called the distribution and measurement system.

Reinhardt, V. S.

Integral storage-bulb and microwave cavity for masers

Mechanically-stable integral storage-bulb/microwave cavity made out of single piece of fused quartz improves frequency stability. Single-piece construction eliminates joints, making cavity dimensionally and hence frequency-stable. Fused quartz is used because of its low thermal expansion coefficient.

Reinhardt, V. S.

The performance of NASA research hydrogen masers

Field operable hydrogen masers based on prior maser designs are presented. These units incorporate improvements in magnetic shielding, lower noise electronics, better thermal control, and have a microprocessor for operation, monitoring, and diagnostic functions. They are ruggedly built for transportability and ease of service anywhere in the world.

Reinhardt, V. S.

FEP plug protects H2 masers

Lifetime of hydrogen-maser bulb is increased by replacing beam stop plate with thick fluorinated ethylene-propylene (FEP) plug inserted in hole opposite beam entrance stem of bulb.

Deluca, J. J.

External bulb variable volume maser

A maser functioning as a frequency standard stable to one part in 10 to the 14th power includes a variable volume, constant surface area storage bulb having a fixed volume portion located in a resonant cavity from which the frequency standard is derived. A variable volume portion of the bulb, exterior to the resonant cavity, has a maximum volume on the same order of magnitude as the fixed volume bulb portion. The cavity has a length to radius ratio of at least 3:1 so that the operation is attained without the need for a feedback loop. A baffle plate, between the fixed and variable volume bulb portions, includes apertures for enabling hydrogen atoms to pass between the two bulb portions and is an electromagnetic shield that prevents coupling of the electromagnetic field of the cavity into the variable volume bulb portion.

Reinhardt, V. S.

A modular multiple use system for precise time and frequency measurement and distribution

A modular CAMAC based system is described which was developed to meet a variety of precise time and frequency measurement and distribution needs. The system was based on a generalization of the dual mixer concept. By using a 16 channel 100 ns event clock, the system can intercompare the phase of 16 frequency standards with subpicosecond resolution. The system has a noise floor of 26 fs and a long term stability on the order of 1 ps or better. The system also used a digitally controlled crystal oscillator in a control loop to provide an offsettable 5 MHz output with subpicosecond phase tracking capability. A detailed description of the system is given including theory of operation and performance. A method to improve the performance of the dual mixer technique is discussed when phase balancing of the two input ports cannot be accomplished.

Reinhardt, V. S.

Time domain phase measuring apparatus

The phase and/or period stability of a device is determined by connecting the device in one orthogonal arm of a phase detector having a mixer. In the other arm is an adjustable, variable phase shift device. The output of the mixer is fed through an active low pass filter to derive a DC voltage indicative of the phase shift. The variable phase device is adjusted so that the DC voltage will nullify the phase shift of the tested device under normal conditions. The DC voltage level is converted into a time interval indicative of the phase change of the tested device by determining when the level equals the amplitude of a low frequency ramp voltage. The interval between adjacent equality points can be measured or the period between a reference point on the ramp voltage and the quality be measured.

Reinhardt, V. S.

Nanosecond time transfer via shuttle laser ranging experiment

A method is described to use a proposed shuttle laser ranging experiment to transfer time with nanosecond precision. All that need be added to the original experiment are low cost ground stations and an atomic clock on the shuttle. It is shown that global time transfer can be accomplished with 1 ns precision and transfer up to distances of 2000 km can be accomplished with better than 100 ps precision.

Reinhardt, V. S.

Variable volume maser techniques

The frequency stability of hydrogen masers in variable volume storage bulbs is discussed in terms of wall shift. Variable volume devices discussed include: Brenner flexible bulb, Debely device, and the concertina hydrogen maser. A flexible cone variable volume element outside the cavity is described.

Reinhardt, V. S.

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.