Search NASASearch

Engineering topics

Ricker, G. R.

Publications and source records attributed to Ricker, G. R..

At least 19 records

Transiting Exoplanet Survey Satellite (TESS)

The Transiting Exoplanet Survey Satellite (TESS) will discover thousands of exoplanets in orbit around the brightest stars in the sky. In a two-year survey, TESS will monitor more than 500,000 stars for temporary drops in brightness caused by planetary transits. This first-ever spaceborne all-sky transit survey will identify planets ranging from Earth-sized to gas giants, around a wide range of stellar types and orbital distances. No ground-based survey can achieve this feat. A large fraction of TESS target stars will be 30-100 times brighter than those observed by Kepler satellite, and therefore TESS . planets will be far easier to characterize with follow-up observations. TESS will make it possible to study the masses, sizes, densities, orbits, and atmospheres of a large cohort of small planets, including a sample of rocky worlds in the habitable zones of their host stars. TESS will provide prime targets for observation with the James Webb Space Telescope (JWST), as well as other large ground-based and space-based telescopes of the future. TESS data will be released with minimal delay (no proprietary period), inviting immediate community-wide efforts to study the new planets. The TESS legacy will be a catalog of the very nearest and brightest main-sequence stars hosting transiting exoplanets, thus providing future observers with the most favorable targets for detailed investigations.

Ricker, G. R.

Correlative Analysis of GRBs detected by Swift, Konus and HETE

Swift has now detected a large enough sample of gamma-ray bursts (GRBs) to allow correlation studies of burst parameters. Such studies of earlier data sets have yielded important results leading to further understanding of burst parameters and classifications. This work focuses on seventeen Swift bursts that have also been detected either by Konus-Wind or HETE-II, providing high energy spectra and fits to E(sub peak). Eight of these bursts have spectroscopic redshifts and for others we can estimate redshifts using the variability/luminosity relationship. We can also compare E(sub peak) with E(sub iso), and for those bursts for which a jet break was observed in the afterglow we can derive E(sub g) and test the relationship between E(peak) and E(sub gamma). For all bursts we can derive durations and hardness ratios from the prompt emission.

Krimm, Hans A.

The AXAF CCD imaging spectrometer

The current status of the instrument design and the status of the CCDs being fabricated for the AXAF CCD Imaging Spectrometer (ACIS) are summarized. The instrument consists of an image recording array of CCDs and a linear arrangement of CCDs to record the spectra formed by the objective grating spectrometer. Both arrays employ CCDs with pixel dimensions which correspond to about 0.5 arcsec samples of the image. The CCDs provide moderate spectral resolution and good detection efficiency over the energy range 0.5 to 10 keV. Spectral resolution of 200 or more is achievable using the objective grating with the grating array. Radiation damage effects are shown to degrade the energy resolution of CCDs. Specially designed CCD pixel architecture is employed together with shielding and low temperature operation to slow the effects of radiation damage.

Garmire, G. P.

Charge-coupled-device X-ray detector performance model

A model that predicts the performance characteristics of CCD detectors being developed for use in X-ray imaging is presented. The model accounts for the interactions of both X-rays and charged particles with the CCD and simulates the transport and loss of charge in the detector. Predicted performance parameters include detective and net quantum efficiencies, split-event probability, and a parameter characterizing the effective thickness presented by the detector to cosmic-ray protons. The predicted performance of two CCDs of different epitaxial layer thicknesses is compared. The model predicts that in each device incomplete recovery of the charge liberated by a photon of energy between 0.1 and 10 keV is very likely to be accompanied by charge splitting between adjacent pixels. The implications of the model predictions for CCD data processing algorithms are briefly discussed.

Bautz, M. W.

The AXAF CCD Imaging Spectrometer Experiment (ACIS)

The ACIS experiment consists of an array of charge coupled device (CCD) chips placed at the focus of the AXAF mirror assembly. The instrument offers a powerful combination of the best qualities of the entire generation of Einstein Observatory detectors. The pixel size is well matched to the resolution of the telescope, while the high quantum efficiency nondispersive spectroscopy capability means that every object imaged will produce a moderate resolution spectrum. In conjunction with the objective gratings the energy resolution increases to 1000 with a loss of efficiency of only 50 percent. While the great capability of ACIS will naturally make it attractive for a wide range of AXAF investigations, ACIS has a particular advantage in fields where it can simultaneously acquire imaged spectra of many objects. These include compact star clusters, star formation regions, the nuclear regions of nearby galaxies, entire galaxies in the Virgo Cluster and the entire Coma Cluster.

Nousek, J. A.

Matching a curved focal plane with CCD's - Wide field imaging of glancing incidence X-ray telescopes

The design of a wide field imaging camera suitable for use with a glancing incidence X-ray telescope is complicated by the sharply concave nature of the optimum focal surface of such a telescope. Such a camera made up of a mosaic of CCDs is being designed which is intended for flight aboard the Advanced X-ray Astrophysics Facility (AXAF). The design rationale and tradeoffs are discussed, and the layout for the imaging CCD array is presented. The related issue of optimizing performance of transmission objective gratings is also discussed, and the array of CCD orientations suitable for this problem is presented.

Nousek, J. A.

Early photometry of comet p/Halley - Development of the coma

The observation of comets over a large range of heliocentric distances can provide important information, taking into account, for instance, the appearance of true cometary characteristics. Photometric evidence is provided regarding coma formation at approximately 5.9 AU, giving attention to aspects of water-ice sublimation. New photometry of p/Halley was obtained when the comet was at 5.9 and 5.1 AU, during 1984 October and 1985 January, respectively. The new observations are compared with data obtained at larger heliocentric distances. It is argued that sustained mass loss from the nucleus began at about 5.9 AU, at a rate which is consistent with production by sublimation from a predominantly water-ice nucleus.

Meech, K. J.

The explosive transient camera (ETC) - An instrument for identification of gamma ray burst optical counterparts

The ETC is a wide-field (3-steradian) electronic camera array which can detect coincident optical flashes with durations of 0.1 to 100 sec. Each array element is a 20 x 30 deg FOV, cooled CCD detector. An optical transient (possibly associated with a gamma ray burst) as faint as B = +11 (1 sec duration) can be detected with an S/N of not less than 20, and its position determined to an accuracy of + or - 10 arcsec. Candidate events 1000 times fainter than the archived event (plate taken in 1928) reported for the November 19, 1978 gamma ray burst by Schaefer (1981) should be detectable in real time. A prototype camera was tested in April 1982 to establish sky background levels and spurious event rejection schemes; a 1/2-ster test version of the ETC was planned for operation in early 1984; expansion to the full 3-ster complement of 16 detectors at each of two sites was planned for the 1984-1985 period.

Ricker, G. R.

Size of a gamma-ray burster optical emitting region

Measured limits on the quiescent optical and IR flux of the Nov. 19, 1978 gamma ray burster event are presented and used to establish a lower limit to the size of the optically emitting region. A total of 305 min of exposure was made, using a CCD with a UV cutoff at 3800 A. It was determined that the size of the optical emitting region is more than an order of magnitude larger than a neutron star. The size of the optical emitting region did not, however, coincide with that of the gamma ray emitting region, indicating that the optical emissions originate from a different area of the region, i.e., from a companion star or accretion disk rather than a neutron star.

Schaefer, B. E.

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.

A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

Vallerga, J. V.

Discovery of three far-red objects in CCD images of the galactic center

Observations of the galactic center with a CCD camera in the far-red (9030-9270 A) have revealed three previously unknown objects which are designated FRS 1, FRS 2, and FRS 3. The three objects have magnitudes of 18.7, 19.5, and 19.7, respectively, and lie within 10 arcsec of the direction of Sgr A West, corresponding to a distance of about 1/2 pc at 10 kpc. FRS 1 lies within the extended 2.2-micron infrared source IRS 16, which may coincide with the dynamical center of the Galaxy. Two interpretations of these far-red objects which have been considered are that (1) they are compact clusters of giant stars, earlier than M0 or (2) they are extremely compact H II regions observed in the forbidden emission of doubly ionized sulfur. Observational tests of these two hypotheses are suggested.

Ricker, G. R.

New measurement of the Fano factor of mercuric iodide

It is pointed out that mercuric iodide (HgI2) shows great promise as a high-resolution X-ray detector for use in X-ray astronomy. Development of mercuric iodide for astronomical work has required investigation of the temperature dependence of the HgI2 crystal parameters such as leakage current, resolution, and mobility of the charge carriers. The first studies in connection with these investigations have led to a new value of the Fano factor of 0.19 + or - 0.03. The best value previously reported was 0.27 measured at room temperature. The new upper limit of 0.19 for the HgI2 Fano factor was determined by cooling the HgI2 crystal and preamp to -20 C. It is concluded that room-temperature energy resolution of HgI2 is not limited by charge generation statistics but rather by collection efficiency.

Ricker, G. R.

X-ray observations of the 1980 Cygnus X-1 'high state'

Observations of intensity transitions in the X-ray emission from the black-hole candidate Cygnus X-1 were made by the Hakucho satellite during the summer of 1980 and are reported here. In addition, the results of hard (20-120 keV) X-ray observations of Cyg X-1 are reported. These data were obtained during the 'high' intensity state by balloon-borne mercuric iodide detectors, and are compared with data obtained at similar energies approximately 1 month earlier (A. Sheepmaker et al., in preparation) during the 'low' intensity state.

Ogawara, Y.

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.

Optical studies of X-ray sources with the MASCOT - A charge-coupled device /CCD/-based astronomical instrument

The performance levels achieved by the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) on the 1.3-m telescope at the McGraw-Hill observatory in March 1981 are discussed along with preliminary data obtained in searches for optical counterparts to four 'empty-field' X-ray sources. In the W band (4000-7000 A), the MASCOT achieved a sky-limited sensitivity of +24.4 mag per sq arcsec in an 1800 s integration. The ability to flatten pictures to a level consistent with (sky + source) photon statistics and readout noise was demonstrated. For the four sources observed, an optical counterpart was established for one source (1413+13) based on positional coincidence (better than 1.8 arcsec), four possible candidates were detected in the error box of another source (1009?35) and upper sensitivity limits were established for optical counterparts in the error boxes for the other two sources (0920+39 and 0931-11).

Ricker, G. R.

X-ray observations of Seyfert galaxies with the Einstein Observatory

Thirty-seven Seyfert galaxies have been observed with the Imaging Proportional Counter on the Einstein Observatory. X-ray emission from 20 Seyfert 1 galaxies, three of which have been previously detected, and from four Seyfert 2 galaxies. Significant correlations are found between the 2 keV X-ray flux and the nonstellar continuum near 3.5 microns, the nonstellar B band continuum, and the H-beta line flux, and also between 0.5-4.5 keV X-ray luminosity and the zero intensity width of the H-beta emission line and the H-beta forbidden O III ratio. These correlations apply to both types of Seyfert galaxy, as well as the X-ray selected QSOs of Gindlay et al., suggesting that the same physical process operates in each one over a continuous range of intrinsic luminosity.

Kriss, G. A.