Search NASA⌕ Search

Engineering topics

Saaski, E. W.

Publications and source records attributed to Saaski, E. W..

At least 19 records

High-performance heat pipes for heat recovery applications

Methods to improve the performance of reflux heat pipes for heat recovery applications were examined both analytically and experimentally. Various models for the estimation of reflux heat pipe transport capacity were surveyed in the literature and compared with experimental data. A high transport capacity reflux heat pipe was developed that provides up to a factor of 10 capacity improvement over conventional open tube designs; analytical models were developed for this device and incorporated into a computer program HPIPE. Good agreement of the model predictions with data for R-11 and benzene reflux heat pipes was obtained.

Saaski, E. W.↗

A high performance cocurrent-flow heat pipe for heat recovery applications

By the introduction of a plate-and-tube separator assembly into a heat pipe vapor core, it has been demonstrated that axial transport capacity in reflux mode can be improved by up to a factor of 10. This improvement is largely the result of eliminating the countercurrent shear that commonly limits reflux heat pipe axial capacity. With benzene, axial heat fluxes up to 1800 W/sq cm were obtained in the temperature range 40 to 80 C, while heat flux densities up to 3000 W/sq cm were obtained with R-11 over the temperature range 40 to 80 C. These very high axial capacities compare favorably with liquid metal limits; the sonic limit for liquid sodium, for example, is 3000 W/sq cm at 657 C. Computational models developed for these cocurrent flow heat pipes agreed with experimental data within + or - 25%.

Saaski, E. W.↗

Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

Saaski, E. W.↗

An investigation of heat pipe meniscus heat transfer

The use of grooved evaporator surfaces in heat pipes has increased in popularity in the past few years primarily due to the reproducibility achievable with grooved walls and the relatively low costs of the threading or extrusion processes involved in their production. The present study combines both analyses and experiments on square groove geometries, with special emphasis on overcoming the limitations of earlier analyses with finite-difference methods and groove-fillet hydrodynamic simplifications. The groove fillet, which has in previous analyses been assumed constant in radius of curvature, is permitted to change in thickness and curvature consistent with hydrodynamics and heat loss from the groove. A model is developed for accurate determination of the effect of constriction resistance on groove performance. The grooved-surface tests to be conducted are briefly described which will provide data under closely controlled operation to allow comparison and verification of the analyses.

Saaski, E. W.↗

Two-phase working fluids for the temperature range 100-350 C

The decomposition and corrosion of two-phase heat transfer liquids and metal envelopes have been investigated on the basis of molecular, bond strengths and chemical thermodynamics. Potentially stable heat transfer fluids for the temperature range 100 to 350 C have been identified, and reflux heat pipe tests initiated with 10 fluids and carbon steel and aluminum envelopes to experimentally establish corrosion behavior and noncondensable gas generation rates.

Saaski, E. W.↗

A structured surface for high performance evaporative heat transfer

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open faced screw thread surfaces. With a groove density of 12.6/cm and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm K have been measured, along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm K at 20 W/sq cm was measured with a 37.8/cm hybrid surface.

Saaski, E. W.↗

Two-Phase Working Fluids for the Temperature Range 50 to 350 C

The decomposition and corrosion of two-phase heat transfer liquids and metal envelopes have been investigated on the basis of molecular bond strengths and chemical thermodynamics. Potentially stable heat transfer fluids for the temperature range 100 C to 350 C have been identified, and reflux heat pipes tests initiated with 10 fluids and carbon steel and aluminum envelopes to experimentally establish corrosion behavior and noncondensable gas generation rates.

Saaski, E. W.↗

Study of a high performance evaporative heat transfer surface

An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open-faced screw thread surfaces. With a groove density of 12.6 cm/1 and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm have been measured along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm was measured with a 37.8 cm/1 hybrid surface.

Saaski, E. W.↗

A passive thermosyphon heat exchanger for residential solar installations

The paper details the development of a thermosyphon water-to-air heat exchanger for residential solar applications. Modeling techniques used in the analysis of thermosyphon performance are included, as well as test results from laboratory-scale experiments. In addition, a description of the initial full-scale prototype is presented, along with experimental test results. Present areas of development are discussed, with an economic comparison of thermosyphon and forced convection heating systems also being included.

Franklin, J. L.↗

Heat pipe temperature control utilizing a soluble gas absorption reservior

A new gas-controlled heat pipe design is described which uses a liquid matrix reservior, or sponge, to replace the standard gas reservior. Reservior volume may be reduced by a factor of five to ten for certain gas-liquid combinations, while retaining the same level of temperature control. Experiments with ammonia, butane, and carbon dioxide control gases with methanol working fluid are discussed.

Saaski, E. W.↗

An investigation of condensation heat transfer in a closed tube containing a soluble noncondensable gas

A more exact one-dimensional condensation heat transfer model for insoluble gases was developed and compared with experimental data. Modifications to this model to accommodate soluble gas behavior were also accomplished, and the effects on gas front behavior demonstrated. Analytical models for condensation heat transfer are documented, and an optical method used for measuring gas concentration profiles is outlined. Experimental data is then presented and interpreted.

Saaski, E. W.↗

An investigation of condensation heat transfer in a closed tube containing a soluble noncondensable gas

An exact one-dimensional condensation heat transfer model for insoluble gases has been developed and compared with experimental data. Modifications to this model to accommodate soluble gas behavior have also been accomplished, and the effects on gas front behavior demonstrated. Analytical models for condensation heat transfer are documented, and a novel optical method used for measuring gas concentration profiles is outlined.

Saaski, E. W.↗

Investigation of an inverted meniscus heat pipe wick concept

A wicking concept is described for efficient evaporation of heat pipe working fluids under diverse conditions. It embodies the high heat transfer coefficient of the circumferential groove while retaining the circumferential fluid transport capability of a thick porous wick or screen. Experimental tests are described which substantiate the efficacy of the evaporation technique for a circumferentially-grooved heat pipe charged alternately with ammonia and R-ll (CCl3F). With ammonia, heat transfer coefficients in the range of 2 to 2.7 W/sq cm K were measured at heat flux densities up to 20 W/sq cm while, with R-ll, a heat transfer coefficient of l.0 W/sq cm K was measured with flux densities up to 5 W/sq cm. Heat transfer coefficients and flux densities were unusually high compared to literature data for other nonboiling evaporative surfaces.

Saaski, E. W.↗

Arterial gas occlusions in operating heat pipes

The effect of noncondensable gases on high performance arterial heat pipes has been investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, have been used to postulate stability criteria for arterial heat pipes. Experimental observations of gas occlusions were made using a stainless steel heat pipe equipped with viewing ports, and the working fluids methanol and ammonia with the gas additives helium, argon, and xenon. Observations were related to gas transport models.

Saaski, E. W.↗

Heat pipe thermal conditioning panel

Thermal control of electronic hardware and experiments on future space vehicles is critical to proper functioning and long life. Thermal conditioning panels (cold plates) are a baseline control technique in current conceptual studies. Heat generating components mounted on the panels are typically cooled by fluid flowing through integral channels within the panel. However, replacing the pumped fluid coolant loop within the panel with heat pipes offers attractive advantages in weight, reliability, and installation. This report describes the development and fabrication of two large 0.76 x 0.76 m heat pipe thermal conditioning panels to verify performance and establish the design concept.

Saaski, E. W.↗

Investigation of arterial gas occlusions

The effect of noncondensable gases on high-performance arterial heat pipes was investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate, and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, were used to postulate stability criteria for arterial heat pipes under isothermal and non-isothermal condensate flow conditions. A rigorous second-order gas-loaded heat pipe model, incorporating axial conduction and one-dimensional vapor transport, was produced and used for thermal and gas studies. A Freon-22 (CHCIF2) heat pipe was used with helium and xenon to validate modeling. With helium, experimental data compared well with theory. Unusual gas-control effects with xenon were attributed to high solubility.

Saaski, E. W.↗

Heat Pipe Thermal Conditioning Panel

The technology involved in designing and fabricating a heat pipe thermal conditioning panel to satisfy a broad range of thermal control system requirements on NASA spacecraft is discussed. The design specifications were developed for a 30 by 30 inch heat pipe panel. The fundamental constraint was a maximum of 15 gradient from source to sink at 300 watts input and a flux density of 2 watts per square inch. The results of the performance tests conducted on the panel are analyzed.

Saaski, E. W.↗

Heat Pipe Thermal Conditioning Panel

The development, fabrication, and evaluation of heat pipe thermal conditioning panels are discussed. The panels were designed and fabricated to be compatible with several planned NASA space vehicles, in terms of panel size, capacity, temperature gradients, and integration with various heat exchangers and electronic components. It was satisfactorily demonstrated that the heat pipe thermal conditioning panel meets the thermal efficiency and heat transport requirements.

Saaski, E. W.↗