Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The level-1 trigger for the SuperCDMS experiment at SNOLAB

The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to Script O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, σn, and a 99.9% trigger efficiency for signal amplitudes of 1.1 σ n in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources

Two photo-neutron sources, Y 88 Be 9 and Sb 124 Be 9 , have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. In this study, we evaluate the yield for nuclear recoil energies between 1 and 7 keV at a temperature of ~ 50 mK . We use a geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on Lightly Ionizing Particles from CDMSlite

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved effcient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than e/(3x10^5), as well as the strongest limits for charge <= e/160, with a minimum vertical intensity of 1.36 x 10^-7 cm^-2s^-1sr^-1 at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^2 to 100 TeV/c^2) and cover a wide range of beta-gamma values (0.1--10^6), thus excluding non-relativistic LIPs with beta-gamma as small as 0.1 for the first time.

Alkhatib, I↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector

This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axionlike particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 g Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 g-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section σ ¯ e is constrained for dark matter masses from 0.5 to 10 4 MeV / c 2 ; in the mass range from 1.2 to 50 eV / c 2 the dark photon kinetic mixing parameter ϵ and the axioelectric coupling constant g a e are constrained. The minimum 90% confidence-level upper limits within the above-mentioned mass ranges are σ ¯ e = 8.7 × 10 - 34 cm 2 , ϵ = 3.3 × 10 - 14 , and g a e = 1.0 × 10 - 9 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on dark photons and axionlike particles from the SuperCDMS Soudan experiment

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c2) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c2 compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4×10-42 cm2 at 5 GeV/c2, a factor of ~2.5 improvement over the previous CDMSlite result.

Agnese, R↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum 252Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is 4.8+0.7-0.9% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at ~4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to ~75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

dark matter, detector calibration, ionization yiel↗

Energy loss due to defect formation from 206 Pb recoils in SuperCDMS germanium detectors

The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.

cryogenic↗