DOE OSTI · 1867681
The level-1 trigger for the SuperCDMS experiment at SNOLAB
Abstract
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to Script O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, σn, and a 99.9% trigger efficiency for signal amplitudes of 1.1 σ n in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Wilson, John S., Theenhausen Meyer, Hanno zu, von Krosigk, Belina, Azadbakht, Elham, Bunker, Raymond A., Hall, J., Hansen, S., Hines, Bruce, Loer, Ben M., Olsen, Jamieson T., Oser, S. M., Partridge, Richard, Pyle, Matt C., Sander, J., Serfass, Bruno, Toback, David, Watkins, S. L., Zhao, X.. 2022-07-05. The level-1 trigger for the SuperCDMS experiment at SNOLAB. https://doi.org/10.1088/1748-0221%2F17%2F07%2Fp07010
Cite the original work for its findings. Save a collection to share your selection of sources.