Search NASA⌕ Search

Engineering topics

Schneider, M. B. (ORCID:0000000197068308)

Publications and source records attributed to Schneider, M. B. (ORCID:0000000197068308).

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Spatially and temporally resolved plasma parameter estimations of laser heated MagLIF relevant gas pipes at NIF

The ability to control laser pre-heat is an integral part of the inertial confinement fusion concept known as Magnetized Liner Inertial Fusion. This process is studied at the National Ignition Facility (NIF) where 4 of the 192 laser beams are propagated through a 1-cm long gas cell where they deposit >20 kJ of energy into the gaseous fuel via inverse bremsstrahlung absorption. This process ionizes the gas, producing a plasma that follows behind the laser front and expands over the radius of the cell. Emission from this plasma, as viewed by a gated x-ray detector, can be used to build spatially and temporally resolved estimations of the pre-heat plasma's density and temperature profiles. This can then be used to estimate the plasma pressure, internal energy, and radiation losses. Estimations show the evolution of the plasma in magnetized and unmagnetized gas cells filled with ambient temperature neopentane (C5H12) +1% Ar, as well as unmagnetized cryogenically cooled (32 K) deuterium +1% Ne filled targets. This analysis shows the effects of initial gas-fill density, composition, and axial magnetization on the time-dependent plasma parameters. Previously, these parameters at the NIF had not been experimentally characterized, and these estimations provided a potential new means of testing radiation magneto-hydrodynamic predictive capability models. Results in unmagnetized targets have strong agreement with simulations. However, in targets with a 19 T applied axial magnetic field, this method yields electron temperatures up to 100% hotter than those predicted by HYDRA codes.

Bremsstrahlung↗

Key advancements toward eliminating the “drive deficit” in ICF hohlraum simulations

This paper, extended from a Letter [Chen et al., Phys. Rev. E 110, L013201 (2024)] published in Phys. Rev. E in 2024, presents detailed results from a set of experiments studying the x-ray drive produced in laser-heated ignition-scale hohlraums at the National Ignition Facility. The results reveal that deficiencies in non-local thermodynamic equilibrium atomics physics calculations of gold emissivity lead to the overestimation of the “M-band” radiation and are responsible for discrepancies in drive predictions vs measurements in these hohlraums. These experiments were performed on ViewFactor targets with the same gas fill and laser pulse shapes as currently used in ongoing ignition experiments. The common hohlraum model with a magnetohydrodynamics heat transport model and a 10%–20% reduction to the M-band absorption and emission opacity can bring the simulations into agreement with several independent measurements, including the absolute radiation flux, the radiation flux in the 2–4 keV spectral range, and spectroscopic measurements of both K-shell dopant and L-shell gold. This new model is applicable to ICF and high-energy density experiments that use gold hohlraums as drivers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of early time outer laser beam reflection inside a cylindrical hohlraum at the National Ignition Facility

In a National Ignition Facility (NIF) cylindrical hohlraum, any specular reflection (“glint”) off the wall from the outer cone (incident angle of 50° and 44° relative to the surface of the wall) laser beam will irradiate the capsule poles. If the glint power is sufficiently large during the picket (early time) of the laser pulse, it may seed high-mode perturbations on the capsule surface that can grow during the implosion. To quantify the glint power on the capsule during the picket by the outer beams, we performed dedicated experiments on NIF using a flat witness foil as a surrogate for the capsule in a half-hohlraum target. We found that the measured glint power is approximately comparable to simulations using a nominal electron conduction flux limiter of f = 0.15, and over an order of magnitude lower than that predicted using f = 0.03 in the wall. Based on our current understanding, we conclude that the glint from the outer beams plays an insignificant role in capsule drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization disequilibrium in K- and L-shell ions

Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

The multi-optics high-resolution absorption x-ray spectrometer (HiRAXS) for studies of materials under extreme conditions

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9–9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8–10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

Stoupin, S. (ORCID:0000000226225270)↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics

In this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments.

Fraenkel, M. (ORCID:0000000291939544)↗