Search NASA⌕ Search

Engineering topics

Schuman, Adam

Publications and source records attributed to Schuman, Adam.

Detonation-induced transformation of graphite to hexagonal diamond

In this work, we explore the structural evolution of highly oriented pyrolytic graphite (HOPG) under detonation-induced shock conditions using in situ synchrotron x-ray diffraction in the ns timescale. We observe the formation of hexagonal diamond (lonsdaleite) at pressures above 50 GPa, in qualitative agreement with recent gas gun experiments. First-principles density functional calculations reveal that under uniaxial compression, the energy barrier for the transition toward hexagonal diamond is lower than that for cubic diamond. Finally, no indication of cubic diamond formation was observed up to >70 GPa.

36 MATERIALS SCIENCE↗

Single-pulse (100 ps) extended x-ray absorption fine structure capability at the Dynamic Compression Sector

Determining real-time changes in the local atomistic order is important for a mechanistic understanding of shock wave induced structural and chemical changes. However, the single event and short duration (nanosecond times) nature of shock experiments pose challenges in obtaining Extended X-ray Absorption Fine Structure (EXAFS) measurements - typically used for monitoring local order changes. Here, we report on a new single pulse (~100 ps duration) transmission geometry EXAFS capability for use in laser shock-compression experiments at the Dynamic Compression Sector (DCS), Advanced Photon Source. We used a flat plate of highly oriented pyrolytic graphite (HOPG) as the spectrometer element to energy disperse x-rays transmitted through the sample. It provided high efficiency with approximately 15% of the x-rays incident on the HOPG reaching an x-ray area detector with high quantum efficiency. This combination resulted in good signal-to-noise ratio (~10 3 ), energy resolution of ~10 eV at 10 keV, EXAFS spectra covering 100s of eV, and good pulse to pulse reproducibility of our single pulse measurements. Ambient EXAFS spectra for Cu and Au are compared to reference spectra, validating our measurement system. Comparison of single pulse EXAFS results for ambient and laser shocked Ge(100) shows large changes to the local structure of the short lived state of shocked Ge. The current DCS EXAFS capability can be used to perform single pulse measurements in laser shocked materials from approximately 9-13 keV. These EXAFS developments will be available to all users of the DCS.

47 OTHER INSTRUMENTATION↗