Search NASA⌕ Search

DOE OSTI · 1673431

Single-pulse (100 ps) extended x-ray absorption fine structure capability at the Dynamic Compression Sector

Abstract

Determining real-time changes in the local atomistic order is important for a mechanistic understanding of shock wave induced structural and chemical changes. However, the single event and short duration (nanosecond times) nature of shock experiments pose challenges in obtaining Extended X-ray Absorption Fine Structure (EXAFS) measurements - typically used for monitoring local order changes. Here, we report on a new single pulse (~100 ps duration) transmission geometry EXAFS capability for use in laser shock-compression experiments at the Dynamic Compression Sector (DCS), Advanced Photon Source. We used a flat plate of highly oriented pyrolytic graphite (HOPG) as the spectrometer element to energy disperse x-rays transmitted through the sample. It provided high efficiency with approximately 15% of the x-rays incident on the HOPG reaching an x-ray area detector with high quantum efficiency. This combination resulted in good signal-to-noise ratio (~10 3 ), energy resolution of ~10 eV at 10 keV, EXAFS spectra covering 100s of eV, and good pulse to pulse reproducibility of our single pulse measurements. Ambient EXAFS spectra for Cu and Au are compared to reference spectra, validating our measurement system. Comparison of single pulse EXAFS results for ambient and laser shocked Ge(100) shows large changes to the local structure of the short lived state of shocked Ge. The current DCS EXAFS capability can be used to perform single pulse measurements in laser shocked materials from approximately 9-13 keV. These EXAFS developments will be available to all users of the DCS.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Das, Pinaki, Klug, Jeffrey A., Sinclair, Nicholas, Wang, Xiaoming, Toyoda, Yoshimasa, Li, Yuelin, Williams, Brendan, Schuman, Adam, Zhang, Jun, Turneaure, Stefan J.. 2020-08-21. Single-pulse (100 ps) extended x-ray absorption fine structure capability at the Dynamic Compression Sector. https://doi.org/10.1063/5.0003427

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗