Search NASA⌕ Search

Engineering topics

Seo, Han Gil

Publications and source records attributed to Seo, Han Gil.

Robust highly durable solid oxide fuel cell cathodes – Improved materials compatibility & self-regulating surface chemistry

Solid oxide fuel cells (SOFCs) are electrochemical conversion devices that directly transform hydrogen or hydrocarbon fuels to electricity, with energy efficiencies as high as 90%, coupled with reduced emissions. Several factors, however, remain to be addressed when considering scale-up of SOFC technology, including the need to overcome decreased performance due to sluggish rates of the oxygen reduction reaction (ORR) at the cathode under reduced temperatures and susceptibility to degradation in performance from surface poisoning e.g. from chromia, while limiting the use of critical raw materials (lanthanides and transition metals) present in high performing mixed ionic electronic conducting electrodes like (La,Sr)CoO 3 (LSC). In this project we explored the key descriptors for determining ORR activity in SOFC electrodes and tried to recover performance degradation by applying them to SOFC electrodes. In order to do this, we first selected a model mixed ionic electronic conducting (MIEC) oxide, Pr-doped CeO 2 (Pr 0.1 Ce 0.9 O 2-δ , PCO), which is a chemically stable fluorite and free of inherent poison sources (e.g. Sr segregation in LSC) that potentially react with external impurities such as Cr-species vaporized from the interconnect. The three approaches originally planned in this project are as follows: 1) evaluation of scavenger exsolution characteristics, 2) study of scavengers gettering efficacy following Cr and Si poisoning and 3) integration of new compositions into porous electrodes. Among them, exceptional progress has been made in 2) and 3), especially understanding the role of surface infiltrants in impacting electrode performance and degradation of PCO materials. We found that the Smith acidity scale for binary oxides serves as a powerful descriptor for tuning and predicting the oxygen exchange kinetics on MIEC PCO surfaces. As a result, with infiltration with binary oxides, ranging from strongly basic (Li 2 O) to strongly acidic (SiO 2 ) onto the surface of porous PCO, it was possible to systematically vary the chemical surface exchange coefficient (k chem ) by 6 orders of magnitude! L i2 O increased k chem by nearly 1,000 times over that of pristine PCO, while SiO 2 decreased k chem by nearly the same factor. Strikingly, although the pre-exponential of k chem scales linearly with the acidity of the infiltrated binary oxide, there is nearly no change in the activation energy. With this insight, we attributed the origin of these dramatic changes in k chem values to the systematic increase and decrease in the surface electron density induced by infiltrated binary oxides. More interestingly, although both Cr 2 O 3 and SiO 2 were determined to be acidic by Smith, suggesting that this feature could likely be the primary reason that these compounds serve to poison the ORR on SOFC cathodes, the effect of poisoning could be subsequently tuned by adding multiple infiltrants and controlling their relative surface acidities. We also systematically examined the effect of serial infiltration of basic and acidic oxides. It turned out that serial infiltration of Li not only recovers approximately 20-fold degraded k chem of PCO by acidic Cr 2 O 3 but its k chem is enhanced even beyond that of the non-infiltrated PCO by more than three orders of magnitude. This was further verified with a screen-printing PCO symmetric cell in terms of the electrode performance (area-specific resistance, ASR) related to approach 3). These observations point to acidity as a key descriptor not only in tuning and predicting the ORR activity of SOFC cathodes that largely determines the overall performance of SOFC, but in mitigating and reactivating poisoned electrode performance. This work provides novel guidelines for making the electrode performance much more active and robust in SOFCs, which can further be applied to all applications requiring oxygen exchange reaction, such as electrolyzers, permeation membranes and gas sensors.

30 DIRECT ENERGY CONVERSION↗

Surface oxygen exchange kinetics of mixed conducting oxides: Dilatometric vs electrical conductivity relaxation study

The surface oxygen exchange kinetics of mixed ionic-electronic conducting (MIEC) oxides play a crucial role in a variety of applications, including solid oxide fuel/electrolysis cells (SOFCs/SOECs), permeation membranes and sensors. To date, a variety of methods, including isotope exchange, electrical conductivity, optical absorptivity and thermogravimetry relaxation, and impedance spectroscopy have been used to measure the oxygen exchange coefficient of MIEC oxides. Each of these methods have their advantages and limitations, depending on the physical and chemical properties of the investigated materials and their sample dimensions and densities. Here, we demonstrate the ability to precisely measure the surface oxygen exchange coefficient (k chem ) of MIEC model material Pr 0.1 Ce 0.9 O 2-δ (PCO) by use of dilatometric relaxation measurements, particularly of interest for materials that exhibit larger chemical expansion coefficients. This is achieved by use of porous bulk specimens to ensure that the contribution of oxygen exchange to the overall kinetics is dominant. We demonstrate that k chem values extracted from chemical expansion relaxation measurements on PCO are nearly identical to those derived from electrical conductivity relaxation measurements. As a result, this provides the opportunity to precisely investigate the oxygen exchange and chemical expansion kinetics of a wide range of materials used in high-temperature applications, particularly where more conventional methods are difficult or inappropriate to apply.

(Pr,Ce)O2-x↗