Search NASA⌕ Search

Engineering topics

Shemyakin, Alexander

Publications and source records attributed to Shemyakin, Alexander.

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Vibration Studies for the CLARA Interferometer

The purpose of the CLARA experiment is to study the nature of undulator radiation emitted by single electrons circulating in the IOTA storage ring. The classical and quantum properties of the radiation are investigated by measuring its coherence length, intensity fluctuations and time correlations. The experiment took data in IOTA Run 4 (2022-2023). The key component of the apparatus is a Mach-Zehnder interferometer (MZI), in which the optical length of one of the arms can be precisely controlled. For some measurements, the fine regulation of the arm length must be smaller than the radiation wavelength. For this reason, the apparatus is particularly sensitive to mechanical vibrations. In this note, we model and measure the effect of vibrations on the performance of the MZI under various conditions. Several improvements of the setup were implemented to minimize systematic distortions of the observed interference patterns. In this report, we present a mathematical model of the effect of mechanical vibrations on observed detector and coincidence rates. We also describe the measurements that were made to estimate the magnitude and spectra of rate fluctuations and their sources in the CLARA MZI under various conditions. Finally, we estimate the magnitude of arm length fluctuations and we deduce the sensitivity to coincidence-rate variations in our apparatus.

43 PARTICLE ACCELERATORS↗