Search NASA⌕ Search

Engineering topics

Siviter, J. H., Jr.

Publications and source records attributed to Siviter, J. H., Jr..

NASA multipurpose airborne DIAL system and measurements of ozone and aerosol profiles

The hardware, operational characteristics, data processing system, and applications of the NASA airborne differential absorption lidar (DIAL) system are described. DIAL functions by assessing the average gas concentration over a specified range interval by analyzing the difference in lidar backscatter signals for laser wavelengths tuned on and off of the molecular absorption line of a gas under investigation. The system comprises two frequency-doubled Nd:YAG lasers pumping two high conversion efficiency tunable dye lasers emitting pulses separated by 100 microsec or less. The return signals are digitized and stored on magnetic tape. The signal collector consists of photomultiplier tubes implanted in a cassegrain telescope. Flight tests of the system involved on-measurements at 285.95 nm and off-measurements at 299.40 nm, which yielded a differential cross section of 1.74 x 10 to the -16th sq cm. In situ measurements with another plane at a nominal altitude of 3.2 km for comparison purposes showed accuracy to within 10% in and above the boundary layer. The system is considered as a test apparatus for more developed versions to be flown on the Shuttle

Browell, E. V.↗

Quantitative remote measurements of pollutants from stationary sources using Raman lidar

The several advantages of Raman lidar for remote measurements of stationary source emissions were quantitatively evaluated using a calibration tank at a distance of 300 m at night. Measurements of approximately 10 to the 3rd ppm SO2 with a 12% accuracy were demonstrated in an observation time of 15 min using a 1.5-J ruby laser at 30 pulses/min, 6-m range resolution, interference filters, photon counting detection, and a 20-cm receiver. Measurement accuracy was checked by measuring known concentrations of SO2 in the tank, by tuning the interference filters through the SO2 Raman line, and by varying the CO2 concentration to very high levels during the SO2 measurements. Evaluation of the seriousness of induced fluorescence from plume aerosols failed due to the inability to simulate the plume aerosols.

Poultney, S. K.↗

Rotating filters permit wide range of optical pyrometry

Gear-driven dual filter disks of graduated density vary linearly with respect to rotation, allowing a wide range of photographic pyrometry. this technique is applicable in metallurgy, glass, plastics and refractory research, and crystallography.

Exton, R. J.↗