Search NASA⌕ Search

Engineering topics

Sokaras, D.

Publications and source records attributed to Sokaras, D..

At least 19 records

Apollo Next Generation Sample Analysis (ANGSA): an Apollo Participating Scientist Program to Prepare the Lunar Sample Community for Artemis

As a first step in preparing for the return of samples from the Moon by the Artemis Program, NASA initiated the Apollo Next Generation Sample Analysis Program (ANGSA). ANGSA was designed to function as a low-cost sample return mission and involved the curation and analysis of samples previously returned by the Apollo 17 mission that remained unopened or stored under unique conditions for 50 years. These samples include the lower portion of a double drive tube previously sealed on the lunar surface, the upper portion of that drive tube that had remained unopened, and a variety of Apollo 17 samples that had remained stored at -27 °C for approximately 50 years. ANGSA constitutes the first preliminary examination phase of a lunar “sample return mission” in over 50 years. It also mimics that same phase of an Artemis surface exploration mission, its design included placing samples within the context of local and regional geology through new orbital observations collected since Apollo and additional new “boots-on-the-ground” observations, data synthesis, and interpretations provided by Apollo 17 astronaut Harrison Schmitt. ANGSA used new curation techniques to prepare, document, and allocate these new lunar samples, developed new tools to open and extract gases from their containers, and applied new analytical instrumentation previously unavailable during the Apollo Program to reveal new information about these samples. Most of the 90 scientists, engineers, and curators involved in this mission were not alive during the Apollo Program, and it had been 30 years since the last Apollo core sample was processed in the Apollo curation facility at NASA JSC. There are many firsts associated with ANGSA that have direct relevance to Artemis. ANGSA is the first to open a core sample previously sealed on the surface of the Moon, the first to extract and analyze lunar gases collected in situ, the first to examine a core that penetrated a lunar landslide deposit, and the first to process pristine Apollo samples in a glovebox at -20 °C. All the ANGSA activities have helped to prepare the Artemis generation for what is to come. The timing of this program, the composition of the team, and the preservation of unopened Apollo samples facilitated this generational handoff from Apollo to Artemis that sets up Artemis and the lunar sample science community for additional successes.

79 ASTRONOMY AND ASTROPHYSICS↗

The insufficiency of the charge transfer model for resonant $\text{XES}$ in $\text{UF}$ 4

Recently, it was suggested that the single-electron charge transfer model (ligand 2p to Uranium 5f transition) could be used to explain the U M 4,5 Resonant X-ray Emission Spectroscopy (XES) of uranium dioxide (UO 2 ) and uranium tetrafluoride (UF 4 ). Here in this report, it is shown that this model produces results inconsistent with a joint consideration of both of the bandgaps of UO 2 and UF 4 and is thus insufficient to explain the observed behavior. An alternative Raman-based model is proposed.

36 MATERIALS SCIENCE↗

Direct measurement of 5f delocalization with U XES

Delocalization of the 5f states in the early actinides in general and U metal in particular is significantly important and yet poorly understood. Here, extant spectroscopic techniques have failed to resolve the situation. Here it will be shown that X-Ray Emission Spectroscopy (XES) of the M 4,5 levels can provide the needed information, with a distinct difference between the delocalized U metal and localized uranium dioxide and uranium tetrafluoride cases. A Peak Ratio (PR) model, built upon electric dipole selection rules, has been developed and utilized, with quantitative agreement between experiment and theory. Possible expansion to other types of 5f mixing systems will be discussed.

36 MATERIALS SCIENCE↗

5f covalency from x-ray resonant Raman spectroscopy

Here, X-ray resonant Raman spectroscopy (XRRS), a variant of resonant inelastic x-ray scattering, has been used to investigate the two prototype systems, UF 4 and UO 2 . Both are U5f 2 and each is an example of 5f localized, ionic behavior and 5f localized, covalent behavior, respectively. From the M 5 XRRS measurements, the 5f band gap in each can be directly determined and, moreover, a clear and powerful sensitivity to 5f covalency emerges.

36 MATERIALS SCIENCE↗

Thorium model and weak 5f delocalization

Recently, it was demonstrated that an empirical model based on bremsstrahlung isochromat spectroscopy of elemental thorium (Th) could be used to explain the experimental results and unoccupied 5f electronic structure for simple localized actinide systems with n = 2/3, 2, 3, and 5, where n is the 5f occupancy. In this work, the thorium model will be extended to provide an understanding of the observed behavior and unoccupied 5f electronic structure in the uranium monochalcogenide systems of uranium sulfide and uranium telluride, in terms of weak 5f delocalization.

36 MATERIALS SCIENCE↗

Unoccupied electronic structure of actinide dioxides

Ligand field density functional theory calculations of the dioxides of thorium, uranium, and plutonium have been combined with high-energy-resolution fluorescence detection (HERFD) in x-ray absorption spectroscopy and inverse photoelectron spectroscopy (IPES) measurements to provide powerful insight into the underlying composition of the unoccupied 5f electronic structure in these 5f localized systems. Fine structure in the 5f 5/2 transitions in HERFD can be directly correlated with the fine structure in the leading edge of the IPES. The shapes, intensities, and systematics in HERFD and IPES are explained in a consistent and rigorous fashion in terms of the j-specific 5f electronic structure.

36 MATERIALS SCIENCE↗

Underlying simplicity of 5f unoccupied electronic structure

Using a simple empirical model based upon the bremsstrahlung isochromat spectroscopy of elemental Th, it is possible to explain the recent high energy resolution fluorescence detection measurements of UF 4 (n = 2) and UCd 11 (n = 3) as well as the new inverse photoelectron spectroscopy of Pu 2 O 3 (n = 5), where n is the 5f occupation number. Furthermore, a critical issue in this analysis is the assumption that the Th 5f states are essentially empty, which will be confirmed both experimentally and computationally. Thus, for 5f systems, this simple model provides a unified and consistent picture of 5f unoccupied density of states in simple, localized systems, as the 5f occupation varies in the early part of the series, for n = 0, 2, 3, and 5.

36 MATERIALS SCIENCE↗

The Limitations of 5f Delocalization and Dispersion

Delocalization in the 5f states of the actinides is an important phenomenon, but poorly quantified. Here, the fundamental limitations of 5f dispersion measurements using angle and momentum resolved variants of photoelectron spectroscopy will be discussed. A novel approach will be suggested, based on a theoretical projection, which should circumvent these limitations: M4,5 X-ray emission spectroscopy. This analysis will utilize the case study of U metal, which can be considered to be the paramount example of 5f dispersion.

36 MATERIALS SCIENCE↗

U M subshell X-ray emission spectroscopy of uranium dioxide: the effect of excitation energy

There are very great differences between the non-resonant U M subshell X-ray Emission Spectra of Uranium Dioxide generated with low and high-energy excitation. Additionally, these different spectra are each supported by theoretical constructs. It will be shown that the differences between these experimental spectra can be reconciled and the utility of both theoretical approaches confirmed, including the use of FEFF in the low energy and high-energy regimes.

36 MATERIALS SCIENCE↗

The X-ray emission of cerium oxide

Using a combination of spectral simulation with FEFF and experimental data for metallic Ce, it has been possible to extract the Cerium Oxide-only M 4,5 X-ray Emission Spectrum (XES) from an experimental result, which had been produced utilizing a combined CeOxide/Ce sample. In this paper, it is shown that the XES emission for CeOxide-only is significantly different for the M 4 and M 5 edges, with the M 4 XES consistent with normal XES and the M 5 XES exhibiting a continued enhancement associated with a threshold effect, connected to Resonant Inverse Photoelectron Spectroscopy (RIPES).

36 MATERIALS SCIENCE↗

Probing Charge Ordering in Fractional Mixed-Valence Charge Density Wave Systems with Oriented HERFD-XANES Spectroscopy

In this paper, we present oriented Pt L III edge high energy resolution fluorescence detected X-ray absorption near edge structure (HERFD-XANES) measurements on a series of structurally tunable quasi-one-dimensional mixed-valence platinum-halide linear chain materials, [Pt(en) 2 ][Pt(en) 2 X 2 ](ClO 4 ) 4 with X = Cl, Br, I, together with ab initio modeling of the spectral components and electronic structure. The materials exhibit a commensurate charge density wave (CDW) with an amplitude controlled by the bridging halide ion, giving rise to fractional mixed valence states. Ab initio FEFF9 modeling of the spectra and the associated angular momentum projected density of states (lDOS) are used to interpret the results, revealing systematic changes in the platinum orbital occupancy through the series of materials that reflect the fractional mixed valence states of the CDW. A significant contribution to a post-edge feature in the oriented spectra is identified as resulting from quantum interference between the final states of the X-ray absorption transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of FEFF analyses to actinide 5f systems

In this paper, the strengths and limitations of FEFF simulations, as applied to actinide systems, are discussed. While the impact of total angular momentum coupling in the 5f manifold is not addressed within the usual FEFF approach, the utility of FEFF is demonstrated.

74 ATOMIC AND MOLECULAR PHYSICS↗

EXAFS as a probe of actinide oxide formation in the tender X-ray regime

Recent developments in Resonant Inelastic X-Ray Scattering Experiments have vastly improved the resolution in X-ray Spectroscopies such as X-ray Absorption. However, the use of Tender X-rays (~3 keV) and the reactivity of actinides such as uranium have given rise to new questions about bulk and surface sensitivity, what constitutes a surface and how to characterize the formation of an oxide. It will be shown herein that the in situ electron scattering features that are part of the RIXS spectrum can be used to quantify the uranium oxide formation and determine cleanliness, independently of the near edge features that provide information about the unoccupied electronic density of states.

36 MATERIALS SCIENCE↗

Towards the Quantification of 5f Delocalization

By using M4,5 X-ray Emission Spectroscopy (XES) in the tender X-ray regime, it is possible to quantify 5f delocalization in the actinides. Previous analyses, utilizing the Branching Ratio (BR) in the N4,5 X-ray Absorption Spectroscopy (XAS), could not discriminate between the cases of localized n = 2 and delocalized n = 3, in uranium materials, where n is the number of 5f electrons on the U entity. Here, it is shown that, by employing the ubiquitous 6p → 3d XES as a point of normalization, the localized n = 2 and delocalized n = 3 cases can be easily distinguished and quantified.

36 MATERIALS SCIENCE↗

A versatile Johansson-type tender x-ray emission spectrometer

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6–5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (~0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (~30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗