Search NASASearch

Engineering topics

Springer, Martin

Publications and source records attributed to Springer, Martin.

Tough Break: Many Factors Make Glass Breakage More Likely

We have seen cases of glass in PV modules breaking differently, and more often, than it did five years ago. There have been many changes to PV module design and materials in that time. But there is probably no single change that is responsible for the problem. Here we summarize the current thinking on PV glass breakage in utility-scale power plants. We share insights from multiple still-running projects at NREL.

14 SOLAR ENERGY

Industrial Energy Storage Review

As the United States moves to net-zero carbon emission by 2050, a transition to renewable energy generation is required. However, the variable nature of renewable energy generation at high penetrations can cause imbalances in generation and transmission of electricity. These imbalances can be circumvented by the deployment of energy storage. Global industrial energy storage is projected to grow 2.6 times in the coming decades, from just over 60 GWh to 167 GWh in 2030. The challenge is to balance energy storage capabilities with the power and energy needs for particular industrial applications. Energy storage technologies can be classified by the form of the stored energy. The most common forms include thermal, chemical, electrochemical, and mechanical storage technologies. The most appropriate storage technology will depend on the unique energy needs of the industrial application. The purpose of this report is to provide a review of energy storage technologies relevant to the U.S. industrial sector, highlighting the applications in industry that will benefit from increased integration of energy storage, as well as the respective challenges and opportunities unique to integrating different storage technologies.

25 ENERGY STORAGE

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY

PV Degradation Tools [SWR-20-71]

This open-source tool functions for calculating degradation of photovoltaic modules. For example, functions to calculate front and rear relative Humidity, as well as Acceleration Factors. A degradation calculation function is also being developed, considering humidity and spectral irradiances models.

Holsapple, Derek