Response of soil bacteria to PUREX chemicals suggests biomarker utility and bioremediation potential

Chemicals involved in plutonium uranium reduction extraction (PUREX) can be released from nuclear reprocessing facilities and accumulate in the environment. We exposed chemically diverse soils to a range of concentrations of key chemicals used in the PUREX process. The responses of soil microbial communities are dependent on soil type, and tributyl phosphate exposure generates the most reproducible changes in microbial communities. We reconstructed the genomes of key bacteria and find several phosphotriesterase genes found only in Rhizobiaceae. The abundance of phosphotriesterase genes is significantly higher in samples exposed to tributyl phosphate. In conclusion, these phosphotriesterase genes may be involved in breakdown of tributyl phosphate, and a means of accessing phosphate for these bacteria.

Bioremediation↗

Enhanced detection limits for radiokrypton analysis

In this paper, we present a method for improving detection limits of Atom Trap Trace Analysis for the krypton radioisotopes 85 Kr and 81 Kr. For the case of 85 Kr this work demonstrates that systematic use of isotopically depleted gas for calibration and extended conditioning of the instrument results in a detection limit of 900 85 Kr atoms per 11 μl of Kr gas, equivalent to a 85 Kr/Kr isotopic abundance of 3 x 10 -15 . This improvement of roughly two orders of magnitude over previously reported limits will help to expand the reach of radiokrypton dating towards longer age ranges where most of the radioisotopes have decayed. Additionally, the method offers an opportunity to investigate radiokrypton production via spontaneous fission within naturally occurring minerals to understand potential underground production of these isotopes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improving the separation of strontium and barium with Sr Resin using chelating eluent solutions

Age dating radioactive 137 Cs and 90 Sr sources, which are a potential concern in radiation dispersal devices, can provide evidence for attribution in a nuclear forensic investigation. Precise measurement of the 137 Cs– 137 Ba or 90 Sr– 90 Zr isotope ratio by ICP-MS in tandem with non-linearity and mass-bias data manipulation dramatically increases precision and decreases uncertainty, leaving inadequate chemical separation efficiencies as a major contributor—and in some cases the lead contributor—to uncertainty in age determination. To improve the separation of these isobars before ICP-MS analysis, we evaluated eluents containing EDTA and DTPA chelating agents against previously studied eluents for their ability to achieve complete removal of Sr and Ba from Eichrom Technologies’ Sr Resin. Barium separation efficiencies using 0.05 M EDTA, pH-adjusted 0.05 M EDTA, and pH-adjusted 0.05 M DTPA were found to be 100.9 ± 2.2%, 99.4 ± 0.8%, and 99.3 ± 1.2%, respectively. Strontium separation efficiencies using 0.05 M disodium EDTA and 0.05 M potassium EDTA were determined to be 100.14 ± 0.53% and 100.19 ± 0.97% respectively. Furthermore, these results demonstrate that eluents containing chelating agents out-perform previously studied eluent solutions at removing barium and strontium from Sr Resin.

07 ISOTOPE AND RADIATION SOURCES↗

An alternative separation procedure for 90 Sr age dating using DGA Resin

The likelihood of an attack by a terrorist organization using a radiological dispersal device (RDD) is much higher than that of an attack with an improvised nuclear device or true nuclear weapon, as much less technical expertise is required to build an RDD. Consequently, there has been an effort to develop methods for age-dating radiological sealed sources in recent years. One such procedure, described by Steeb et al., is used for determining the age of 90 Sr sources. That procedure utilized a rather expensive extraction chromatography resin and was based on an uncommon apparatus with limited sample capacity for the separation step. The procedure also left the Zr fraction contaminated with the radioactive 90 Y daughter nuclide. This work investigates using an alternative separation scheme that utilizes a less costly resin in a widely available column configuration and results in the isolation of 90 Sr's stable granddaughter, 90 Zr, without 90 Y contamination. This allows the zirconium quantification to be done with a mass spectrometer outside the radiological environment and increases the number of instruments capable of making the measurement, which could allow measurements to be made more quickly.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Use of an ion mobility spectrometer for detecting uranium compounds

The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown the ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-destructive internal nuclear forensic investigation at Argonne: discovery of a Pu planchet from 1948

A plutonium alpha standard dating from 1948 was discovered at Argonne National Laboratory and characterized using a number of non-destructive analytical techniques. The principle radioactive isotope was found to be 239 Pu and unique ring structures were found across the surface of the deposition area. Due to chronological constraints on possible sources and its high isotopic purity, the plutonium in the sample was likely produced by the Oak Ridge National Lab X-10 Reactor. As a result, it is proposed that the rings are resultant through a combination of polishing and electrodeposition, though the hypothesis fails to address a few key features of the ring structures.

239Pu↗

Age-dating methodology for 137 Cs ceramic sources

Here, age-dating of 137 Cs ceramic sources is shown to be a viable technology for nuclear forensics investigations. The 137 Cs age-dating method in general, however, could be substantially improved by using radiometric rather than ICP-MS measurement of the 137 Cs isotope and by refining the Cs/Ba separation process. With these improvements, uncertainty in the age of a 60-year-old source decreases from 1.35 to 0.68 y.

137Cs ceramic↗

Technologies for pre-screening IAEA swipe samples

During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of an external radiation field on handheld XRF measurements for nuclear forensics applications

X-ray fluorescence (XRF) is an attractive technique for nuclear forensics applications. We evaluated a handheld, portable XRF device by applying an external radiation field (10 mR/h to 17 R/h) using two types of radiography sources: a 60 Co radiography camera to observe effects from high-energy gamma emissions and an 192 Ir radiography camera to observe effects from several low-energy gamma (0.604, 0.468, and 0.317 MeV) and decay daughter x-ray emissions. External radiation tests proved that radiation, in general, has a significant effect on the dead time or background at dose rates over 1 R/hr for both the 192 Ir and 60 Co sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology recommendations for pre-screening of IAEA swipe samples

Argonne and Oak Ridge National Laboratories have prepared an analysis of recommended, possible, and not recommended technologies for pre-screening and prioritizing IAEA swipes. The analytical techniques listed under the recommended technology list are the most promising techniques available to date. The recommended list is divided into two sections: Argonne’s recommended techniques and Oak Ridge’s recommended techniques. This list was divided based upon the expertise of staff in each subject area and/or the instrumentation available at each laboratory. The following section, titled Possible Techniques, is a list of analytical techniques that could be used for pre-screening and prioritizing swipes if additional instrumentation and effort were provided. These techniques are not necessarily top priority, but should not be discounted for future or expanded efforts. Lastly, a list of not recommended techniques is provided to outline the analytical methods and instrumentation that were investigated by each lab but deemed not suitable for this task. In addition to the recommendation list, a short procedure is provided outlining the steps followed for destructive analysis by the Network of Analytical Laboratories (NWAL) for determination of uranium concentrations, isotopic content of sample and swipe. Swipes generated for this project will be given to ORNL’s NWAL laboratory for analysis after analysis by other techniques at both laboratories.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗