Search NASASearch

Engineering topics

Suekane, F.

Publications and source records attributed to Suekane, F..

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS

Evaluation of the performance of event reconstruction algorithms in the JSNS 2 experiment using a 252 Cf calibration source

JSNS 2 investigates short-baseline neutrino oscillations using a 24-meter baseline and a 17-tonne Gd-loaded liquid scintillator target. Accurate event-reconstruction algorithms are crucial for analyzing experimental data. The algorithms undergo meticulous validation through calibration with a 252 Cf source. This paper outlines the methodology and evaluates the reconstruction performance, focusing on neutrino interactions up to approximately 50 MeV for sterile neutrino searches. Both 252 Cf and Michel electron events are studied to evaluate reconstruction accuracy. The analysis concludes that the uncertainty of the fiducial volume, with an appropriate correction, is much less than the requirement of JSNS 2 requirement (10%). Furthermore, the energy resolution is measured to be 3.3 ± 0.1% for the Michel electron endpoint and 4.3 ± 0.1% for the n-Gd peak in the central region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Characterization of a radiation detector based on opaque water-based liquid scintillator

Here, we present the characterization of a novel radiation detector based on an opaque water-based liquid scintillator. Opaque scintillators, also known as LiquidO, are made to be highly scattering, such that the scintillation light is effectively confined, and read out through wavelength-shifting fibers. The 1-liter, 32-channel prototype demonstrates the capability for both spectroscopy and topological reconstruction of point-like events. The design, construction, and evaluation of the detector are described, including modeling of the scintillation liquid optical properties and the detector’s response to gamma rays of several energies. A mean position reconstruction error of 4.4 mm for 1.6 MeV-equivalent events and 7.4 mm for 0.8 MeV-equivalent events is demonstrated using a simple reconstruction approach analogous to center-of-mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS