Search NASA⌕ Search

Engineering topics

Sutton, S. R.

Publications and source records attributed to Sutton, S. R..

40 records · Page 3

Non-destructive trace element microanalysis of as-received cometary nucleus samples using synchrotron x ray fluorescence

The Synchrotron X ray Fluorescence (SXRF) microprobe at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, will be an excellent instrument for non-destructive trace element analyses of cometary nucleus samples. Trace element analyses of as-received cometary nucleus material will also be possible with this technique. Bulk analysis of relatively volatile elements will be important in establishing comet formation conditions. However, as demonstrated for meteorites, microanalyses of individual phases in their petrographic context are crucial in defining the histories of particular components in unequilibrated specimens. Perhaps most informative in comparing cometary material with meteorites will be the halogens and trace metals. In-situ, high spatial resolution microanalyses will be essential in establishing host phases for these elements and identifying terrestrial (collection/processing) overprints. The present SXRF microprobe is a simple, yet powerful, instrument in which specimens are excited with filtered, continuum synchrotron radiation from a bending magnet on a 2.5 GeV electron storage ring. A refrigerated cell will be constructed to permit analyses at low temperatures. The cell will consist essentially of an air tight housing with a cold stage. Kapton windows will be used to allow the incident synchrotron beam to enter the cell and fluorescent x rays to exit it. The cell will be either under vacuum or continuous purge by ultrapure helium during analyses. Several other improvements of the NSLS microprobe will be made prior to the cometary nucleus sample return mission that will greatly enhance the sensitivity of the technique.

Sutton, S. R.↗

Copper and nickel partitioning in iron meteorites

Trace element analyses using proton induced X-ray emission and synchrotron X-ray fluorescence have been made on metal and troilite from nine iron meteorites representing five geochemical groups. Nickel and copper distribution coefficients D (troilite/metal) vary by factors of 600 and 20, respectively, correlate positively with kamacite bandwidth and correlate negatively with bulk nickel content. Meteorites with bulk Ni of less than 10 percent have Cu-enriched troilite while those with Ni greater than 10 percent have Cu-depleted troilite. Since magmatic evolution and partial melting will produce Cu-enriched troilite only, the observation of Cu-depleted troilite in Ni-rich meteorites is evidence for subsolidus reequilibration, a process which reduces D(Cu) by transfer of Cu to exsolving metal. Elemental redistribution may have played an important role in establishing the present chemical trends in iron meteorites.

Sutton, S. R.↗

Trace element analyses of spheres from the melt zone of the Greenland ice cap using synchrotron X ray fluorescence

Synchrotron X-ray fluorescence spectra of unpolished iron and chondritic spheres extracted from sediments collected on the melt zone of the Greenland ice cap allow the analysis of Ni, Cu, Zn, Ga, Ge, Pb, and Se with minimum detection limits on the order of several parts per million. All detected elements are depleted relative to chondritic abundance with the exception of Pb, which shows enrichments up to a factor of 500. An apparent anticorrelation between the Ni-content and trace element concentration was observed in both types of spherules. The fractionation patterns of the iron and chondritic spheres are not complementary and consequently the two iron spheres examined in this study are unlikely to result from ejection of globules of Fe/Ni from parent chondritic micrometeoroids.

Chevallier, P.↗

Thermoluminescence of Antarctic meteorites: A rapid screening technique for terrestrial age estimation, pairing studies and identification of specimens with unusual prefall histories

Thermoluminescence (TL) is a promising technique for rapid screening of the large numbers of Antarctic meteorites, permitting identification of interesting specimens that can then be studied in detail by other, more definite techniques. Specifically, TL permits determination of rough terrestrial age, identification of potential paired groups and location of specimens with unusual pre-fall histories. Meteorites with long terrestrial ages are particularly valuable for studying transport and weathering mechanisms. Pairing studies are possible because TL variations among meteorites are large compared to variations within individual objects, especially for natural TL. Available TL data for several L3 fragments, three of which were paired by other techniques, are presented as an example of the use of TL parameters in pairing studies. Additional TL measurements, specifically a blind test, are recommended to satisfactorily establish the reliability of this pairing property. The TL measurements also identify fragments with unusual pre-fall histories, such an near-Sun orbits.

Sutton, S. R.↗