Search NASA⌕ Search

Engineering topics

Tarka, M.

Publications and source records attributed to Tarka, M..

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for two-neutrino double-beta decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba with the complete EXO-200 dataset*

A new search for two-neutrino double-beta (2νββ) decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90% confidence level half-life sensitivity of 2νββ decay to the $0$$^{+}_{1}$ state of 136 Ba is 2.9 x 10 24 yr using a total 136 Xe exposure of 234.1 kg yr. Furthermore, no statistically significant evidence for 2νββ decay to the $0$$^{+}_{1}$ state is observed, leading to a lower limit of $T$$^{2v}_{1/2}$(0 + → $0$$^{+}_{1}$) > 1.4 x 10 24 yr at 90% confidence level, improved by 70% relative to the current world's best constraint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generative adversarial networks for scintillation signal simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network — a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. Furthermore, the network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

47 OTHER INSTRUMENTATION↗

First test results of the trans-impedance amplifier stage of the ultra-fast HPSoC ASIC

Abstract We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 μm thick AC-LGAD. The evaluation of the analog front end with β-particles impinging on 3 × 3 AC-LGAD arrays (500 μm pitch, 200 × 200 μm 2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

Instruments & Instrumentation↗

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semitransparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97 ± 0.04 mm/µs and (-0.69 ± 0.05)%/K for liquid xenon, and 1.42 ± 0.03 mm/µs and (+0.11 ± 0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

Njoya, Oumarou↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Spectral Shape of the $β$-Decay of 137 Xe to the Ground State of 137 Cs in EXO-200 and Comparison with Theory

Herein we report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique $β$-decay transition 137 Xe ( 7/2 - ) → 137 Cs ( 7/2 + ) . The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗