Search NASA⌕ Search

Engineering topics

Taylor, Charles Edward

Publications and source records attributed to Taylor, Charles Edward.

At least 19 records

Modelling Beam Loss Within the LANSCE Proton Storage Ring

Several upgrades are being considered for the proton storage ring (PSR) at the Los Alamos Neutron Science Center (LANSCE) to reduce beam loss and thereby reduce the cooldown period of the PSR following a beam run. First, we have considered an increased beam pipe diameter would reduce beam loss due to beam scraping caused by misalignments and tuning errors. However, this would require increased pole-to-pole gap height within the dipoles and quadrupoles, which would change their effective length and alter their fringe fields. The effect of different magnet gaps on the beam optical parameters and on beam loss was studied using the simulation codes MAD-X and PyORBIT. Second, we are developing a detailed particle tracking model within the framework of the simulation package General Particle Tracer (GPT) for the PSR H - stripping system. This model will be used to study the effect of the stripper foil parameters (position, composition, areal density, depth, etc.) on first-turn losses, where most of the observed beam loss and emittance growth occurs due to foil scattering, foil stripping, and Lorentz stripping. The model implements C++ custom elements created to model foil scattering, foil stripping, and Lorentz stripping, as these are not built-in features of GPT. The preliminary results of the MAD-X and PyORBIT simulations, as well as the GPT simulation model, is described in this tech note.

43 PARTICLE ACCELERATORS↗

Experimental Safe Extremum Seeking for Accelerators

Here, we demonstrate the recent designs of safe extremum seeking (Safe ES) on the 1-km-long charged particle accelerator at the Los Alamos Neutron Science Center (LANSCE). Safe ES is a modification of extremum seeking (ES) which, in addition to minimizing an analytically unknown cost, also employs a safety filter based on an analytically unknown control barrier function (CBF) safety metric. Tuning is necessitated by accelerators being large complex systems, with many drifting parameters due to thermal effects and degradation. At the same time, safe operation (the maintenance of state constraints) is crucial, as damage brings astronomical costs, both financially and in operation downtime. Our measured (but analytically unknown) safety metric is the beam current. We perform multivariable Safe ES on three accelerator applications, in which we adapt 4, 6, and 3 magnet strength parameters, respectively. Two of the three applications are for validated simulation models of beamlines at LANSCE: the first for the proton radiography (pRad) beamline of 800-MeV protons for spot size tuning; the second on a high-performance code, HPSim, for tuning the low-energy beam transport (LEBT) region that contains a beam of 750-keV protons. The third is an experimental tuning of the steering magnets in the LEBT at LANSCE.

43 PARTICLE ACCELERATORS↗

LAMP Low-Energy Region Options: Workshop Report and Ranking Assessment

The LANSCE accelerator complex at Los Alamos National Laboratory provides beam to five user facilities: IPF, pRad, UCN, WNR and the Lujan Center. Each user facility receives a beam tailored to its specific requirements, including species (H+ or H- ) and beam pulse format. The capabilities and beam requirements of the LANSCE user facilities are documented elsewhere. The core components of the LANSCE accelerator complex – the beam source area, drift-tube and cavity-coupled linear accelerators – are more than 50 years old; a critical subsystem for beam delivery to the Lujan Center, the proton storage ring (PSR), is approximately 40 years old, with its last major refresh being completed in the late 1990s. The LAMP project is intended to begin a revitalization and update of the LANSCE accelerator complex, starting with the beam source region, drift-tube linac, and PSR.

43 PARTICLE ACCELERATORS↗

LAMP-PSR Scoping Studies Report

This report summarizes work performed from July – September 2023, performing an initial evaluation for the LANSCE Proton Storage Ring upgrade option “B.” The studies identified potential pathsforward, performing initial beam dynamics studies, and surveying various technology options different aspects of the upgrade. Taken together, the studies provide an “early look” at the feasibility, challenges and alternative methods for pursuing Option “B,” and give guidance towards more detailed design concept development needed as work progresses. Generally speaking, no major obstacles were identified in pursuing the Option “B” PSR upgrade path in terms of the machine physics or overall system architecture. Several areas of concern have been identified; we note that these primarily center on technology choice and must be addressed regardless of the upgrade path selected, and none of the concerns are considered insurmountable.

43 PARTICLE ACCELERATORS↗

Diagnostics for PSR Upgrade

This report discusses the diagnostics upgrade plan for the PSR. The PSR diagnostics under discussion include beam position and phase monitor (BPPM), wirescanners, wall current monitors, bunch shape monitors, laser notchers, and diamond array detectors. Existing diagnostics at the PSR include beam position monitors (BPM), a wirescanner, and a wall current monitor. All existing diagnostics need modernization, as part of the PSR upgrade plan. Meanwhile, we will introduce minor changes to improve the existing setups, which will enhance the performance and the longevity of the diagnostics equipment and components in the upgraded PSR operation. On the other hand, new, advanced, and available diagnostic technologies at a high technology readiness level (TRL) can also be considered for implementation for the PSR upgrade. In this note, we go through all types of diagnostics, introducing their basic principle, operating status, and plans for the PSR upgrade.

43 PARTICLE ACCELERATORS↗

Charge per Micro-Pulse Calculation for Ideal Lujan and WNR beams

A complete redesign of the LANSCE front-end is currently under development for the Los Alamos Modernization Project (LAMP). This includes the replacement of the traditional Cockroft-Walton injection system to the newer radiofrequency quadrupole (RFQ) standard. LANSCE accelerates both H- and H+ beams and therefore requires an unconventional application for RFQ systems. A new facility could consider using an independent RFQ for each beam species. However, with the tight space of the LANSCE injector facility, it would prove difficult to instrument. Our initial studies have shown that a single RFQ could be used. The negatively- and positively-charged direct current (DC) beams are shaped, bunched, and accelerated out of phase to each other, with very little interaction. This would work for all possible H+ beam gates and most H- Beam gates. However, a challenge arises with the Weapons Neutron Research (WNR) beam structure that requires the acceleration of bunched beams at higher charge density per pulse. The Long Bunch Enable Gate (LBEG) used for the Lujan center is the best example of a standard injector beam gate. The beam gate, or Macro-Pulse (MP), is 625-us long, separated by at least 8.3 ms. A chopper is used to dice the MP into 1750 mini-Pulses (mP), which are 290-ns wide. After chopping, the MP contains 100,000 micro-Pulses (uP), which are generated by the linac acceleration structure modulated at 201.25 MHz; that is, the micro-Pulses are separated 5 ns apart from each other. The H+ beam structure will be very similar once a chopper is added to its transport. However, the Multi-Pulse Enable Gate (MPEG) used for WNR is significantly different in structure. In this case, the mP is chopped to be only 35-ns wide. This width is then rotated into a single 201.25 MHz RF bucket using the Low Frequency Buncher (LFB). This is proving difficult for the RFQ design in the LAMP upgrade. We began investigating the amount of current sent to WNR for two reasons. Firstly, we wanted to find a solution to avoid using the Low Frequency Buncher to simplify the LAMP RFQ design. It is simple to inject and accelerate a 35 mA DC beam in the LAMP RFQ (this is done in numerous accelerator facilities). However, injecting a short bunch with a larger current (once compressed to 5 ns to meet the RFQ frequency) may be difficult. Second, we have a technique called PSR2WNR in which we do not employ the Low Frequency Buncher, but rather accumulate 5 LBEG uP (5 ns) in the PSR and deliver the accumulated beam to WNR every 1.8 us. As a result, we could provide to WNR with five accumulated LBEG uPs every shot. The goal here is to create a rapid kicker with a frequency response of 555 kHz. DARHT-II and other accelerator facilities have constructed kickers of this type for other uses, and our engineers consider this technology as feasible.

43 PARTICLE ACCELERATORS↗

PSR Upgrade Overview

Explore the source record for details and available documents.

Accelerator Design, Technology, and Operations↗

New signature method for identifying organic material in atmosphere and water samples

The levels of plastic contamination in the earth’s oceans have steadily increased over the past century, creating a threat to marine life and increasing climate change. Several methods have been developed over the past decade to try to determine the amount and accumulation rate of plastic impurities in the ecosystem. These methods have proven promising but suffer from long measurement times, bulky non-mobile systems, and sample degradation. We propose a smaller, faster system that employs an electron beam to examine seawater samples for polyethylene contamination levels. This process generates a full electron and photon energy spectrum analyses based on the subatomic particles generated from electron interactions. Our simulations have already been developed based on the known molecular composition of seawater and polyethylene, showing the possibility of discerning molecular plastics from microorganisms. With a system the size of a suitcase, this system would be easily deployable to remote locations around the world or installed as a monitoring system for manufacturing facilities. This concept could lead to a new methodology for the science of signatures and be applied to other biological hazard investigations, such as general virus detection.

43 PARTICLE ACCELERATORS↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗

Captain Electronics Technical Report

This report details the current layout of the electronics for the mini-CAPTAIN detector system, as well as the lessons learned during commissioning. We will present some electronics suggestions for future LArTPC systems. Mini-CAPTAIN is one of three detectors used in the Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAPTAIN) project at Los Alamos National Lab (LANL). The detector uses many of the same electronic components as current and developing LArTPC experiments. This includes the motherboards, service cards, amplifiers and ADC made by Brookhaven National Laboratory (BNL) and the front-end modules (FEM) made by Nevis Labs. The cold electronics performed well in both vacuum and cryogenic environments after months of exposure. Mini-CAPTAIN was tested with two liquid nitrogen and three liquid argon run cycles. The final testing was performed at the Weapons Neutron Research (WNR) facility at LANSCE. Mini-CAPTAIN was able to maintain a clean electrical signal through most of the test cycles. Most noise reduction was achieved with power source filtering and careful attention to the ground configuration. Direct oscilloscope probing on the front-end output provided the fastest analysis and correction of noise sources. Ground path assumptions and integrity were verified with frequent impedance checks. A high voltage break down event damaged some of the channels on the motherboards and a number of the wire decoupling capacitors. This temporarily introduced significant noise on the wire planes due to current leakage. The detector was taken apart and reassembled three times, with successful noise reduction after each activity. The current raw signal-to-noise ratio is 9 to 1.

42 ENGINEERING↗