Search NASA⌕ Search

Engineering topics

Thompson, N.

Publications and source records attributed to Thompson, N..

25 records · Page 2

The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 μm, close to theoretical predictions. Results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

47 OTHER INSTRUMENTATION↗

Architectural considerations for recirculated and energy recovered hard XFEL drivers

A confluence of events motivates discussion of design options for hard XFEL driver accelerators. Firstly, multiple superconducting radio-frequency (SRF) driven systems are now online (European XFEL), in construction (LCLS-II), or in design (MARIE); these provide increasing evidence of the transformational potential they offer for fundamental science with its concomitant benefits. Secondly, operation of 12 GeV CEBAF* validates use of recirculation in high energy SRF linacs. Thirdly, advances in the analysis and control of effects such as coherent synchrotron radiation (CSR) and the microbunching instability (uBI) have been recently achieved. Collectively, these developments offer insights providing extended facility science reach, reduced costs, multiplicity (i.e., support of numerous FELs operating over a range of wavelengths), and enhanced scalability and upgradability (to higher powers and energies). We will discuss the relationship amongst the various threads, and indicate how they inform design choices for the system architecture of an option for the UK-XFEL** - that of a staged multi-user X-ray FEL and nuclear physics facility based on a multi-pass recirculating SRF CW linac.

Benson, Stephen V.↗

Development of an In-Beam Neutron Flux Monitor for Time of Flight Capture Measurements

Accurate nuclear data are important in several aspects of nuclear engineering, such as reactor simulations, nonproliferation, and criticality safety. One of the nuclear data measurements that requires reduced uncertainties in its related cross-sections is neutron capture. The neutron capture cross-sections have particular deficiencies in the incident neutron energy range from 1 keV to 1 MeV. This is due to the predominance of scattering reactions in this energy region. In order to provide more accurate measurements in this energy region, a new experimental setup has been designed and created at Rensselaer Polytechnic Institute (RPI). This experiment utilizes several C{sub 6}D{sub 6} detectors in a low mass system to minimize the effects of neutron scattering on the experiment. In order to determine the capture yield for the measurements, several additional factors need to be known about the neutron beam including the energy dependence of the neutron flux incident on the sample. A detector made from a thin piece of EJ-204 plastic scintillator was designed to measure the neutron flux, as a function of incident neutron energy, during the capture measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Research Reactor Protocol for Neutron Multiplication Measurements

Establishing a protocol for measurements on research reactors is the next step in advanced subcritical neutron multiplication inference measurements. Such measurements can help identify deficiencies and quantify uncertainties in nuclear data and validate predictive Monte Carlo radiation transport simulation capabilities related to subcritical neutron multiplication inference techniques. This work expands on previous benchmark-quality efforts performed at the National Criticality Experiments Research Center (NCERC) located in Nevada, including subcritical experiments with a 4.5-kg {alpha}-phase plutonium sphere surrounded by copper, tungsten and nickel. Evaluations of the nickel and tungsten measurements have both been accepted into the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The nickel benchmark was the first ICSBEP-accepted evaluation of measurements using the Feynman Variance-to-Mean method based on the Hage-Cifarelli formulism, and was the culmination of many years of subcritical experiment research. To help establish a protocol for research reactor-based subcritical measurements, a series of Critical and Subcritical {Phi}-Power Experiments at Rensselaer (CaSPER) have been designed. This neutron multiplication measurement series will be executed at the Rensselaer Polytechnic Institute Walthousen Reactor Critical Facility (RPI-RCF) in upstate New York. The RPI reactor facility can provide benchmark-quality integral experimental configurations where different reactivity states can be achieved by varying the control rod height/water height in the reactor. The diversity of achievable configurations are also unique in contrast to previous subcritical benchmark measurements in that they are spatially complex, involve different materials (fuel, moderator), and are characterized by system-specific neutron cross section sensitivities (various energy ranges and neutron reaction contributions). It is worth noting that previous proof-of-concept subcritical measurements have been performed on thermal systems at NCERC, at a variety of reactivity states by separation distance, yet it was not possible to know the reactivity of various configurations accurately for benchmarking (there are no control rod worth curves as there are no control rods). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capture Cross Section Measurements in {sup nat}Fe and {sup 181}Ta from 1 to 2000 keV Using a New C6D6 Detector Array

A new array of four C6D6 detectors has been developed at the Rensselaer Polytechnic Institute Gaerttner LINAC center for the purposes of measuring neutron capture cross sections in the keV resonance region with low sensitivity to scattered neutrons. The new detection apparatus incorporates low-mass, low cross-section materials to reduce neutron sensitivity, and uses digital data acquisition equipment to enable saving of the full waveform output of each detector module for offline analysis. Capture yields are determined by applying the total energy method and pulse height weighting technique during the analysis of the saved data. Measurements have been performed on samples of iron and tantalum using the new system, with results consistent with existing data libraries. (authors)

42 ENGINEERING↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗