Search NASASearch

Engineering topics

Timothy, J. G.

Publications and source records attributed to Timothy, J. G..

At least 37 records · Page 2

Dynamic range considerations for EUV MAMA detectors

The multianode microchannel array (MAMA) has been chosen as the detector for two instruments on the ESA/NASA Solar Heliospheric Observatory. The response of the MAMA to the two extreme types of solar spectra, disk and corona, have been modeled with a view toward evaluating dynamic range effects present. The method of MAMA operation is discussed, with emphasis given to modeling the effect of electron cloud charge spreading to several detector anodes and amplifiers (n-fold events). Representative synthetic EUV spectra have been created. The detector response to these spectra is modeled by dissecting the input photon radiation field across the detector array into contributions to the various amplifier channels. The results of this dissection are shown for spectral regions across the entire wavelength region of interest. These results are used to identify regions in which total array photon counting rate or individual amplifier rate may exceed the design limits. This allows the design or operational modes to be tailored to eliminate the problem areas.

Illing, Rainer M. E.

Imaging extreme ultraviolet spectrometer employing a single toroidal diffraction grating - The initial evaluation

The design and test results of a high-efficiency EUV imaging spectrometer employing a concave toroidal grating which is illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface are discussed. Photographic tests and initial photoelectric tests with a two-dimensional pulse-counting detector system demonstrate the excellent image quality of the grating at wavelengths near 600 A. Applications of the spectrometer for the study of nonsolar objects and solar regions (including the chromosphere, transition region, and corona) are considered.

Huber, M. C. E.

High-resolution detectors for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of pulse-counting imaging array detectors designed specifically for astrophysical investigations in space. The MAMAs have a number of unique performance characteristics which make them particularly suitable for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths. First, they employ 'solar blind' photocathodes eliminating the 'red leak' problem associated with solid state arrays such as the CCDs. Second, they operate with zero readout noise, yielding photon-statistics limited signals. Third, they utilize a random readout technique and can determine both the location of a detected photon and also its arrival time to an accuracy of the order of 100 ns. This paper gives an overview of the construction, mode of operation, and performance characteristics of the MAMA detectors and describes the current status of the development program.

Timothy, J. G.

Position sensitivity of MAMA detectors

The results of laboratory and telescopic measurements of the position sensitivity of a visible MAMA detector utilizing a 'coarse-fine' array are presented. The photometric accuracy of this detector was determined under point source illumination. It was found that computed centroid positions are accurate across the entire array to within 0.04 pixels.

Morgan, J. S.

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

A high-efficiency, extreme ultraviolet (EUV) imaging spectrometer is constructed and tested. The spectrometer employs a concave toroidal grating illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface. The toroidal grating has been fabricated by a new technique employing an elastically-deformable sub-master grating replicated in a spherical form and then mechanically distorted to produce the desired aspect ratio of the toroidal surface for stigmatic imaging over the selected wavelength range. The fixed toroidal grating used in the spectrometer is then replicated from this surface. Photographic tests and initial photoelectric tests with a two-dimensional, pulse-counting detector system verify the image quality of the toroidal grating at wavelengths near 600 A. The results of these tests and the basic designs of two instruments which could employ the imaging spectrometer for astrophysical investigations in space are described; i.e., a high-resolution EUV spectroheliometer for studies of the solar chromosphere, transition region, and corona; and an EUV spectroscopic telescope for studies of non-solar objects.

Timothy, J. G.

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.

Support of the balloon-borne ultraviolet stellar spectrograph

A (256 x 1024)-pixel imaging ultraviolet Multi-mode Microchannel Array (MAMA) detector system for flight was fabricated, evaluated, and environmentally tested for flight on the Balloon Borne Ultraviolet Stellar Spectrograph (BUSS). The goal of the program was to replace the existing SEC Vidicon with the pulse-counting MAMA detector in order to, first, improve the overall sensitivity of the BUSS telescope and spectrograph for observations of stars down to m sub v = 7 and fainter, and, second, to improve the spectral resolution and wavelength accuracy by eliminating the image drifts in the Vidicon caused by magnetic field effects. A sealed MAMA detector tube structure employing a remotely processed photocathode mounted on a window in proximity focus with the front face of the MCP was developed to avoid contamination produced by a noisy and unstable device. The configuration of the BUSS detector system in its flight ready configuration is shown. The quantum efficiency curve for the semi-transparent Cs2Te photocathode is also shown.

Timothy, J. G.

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.

An imaging extreme ultraviolet spectrometer for astrophysical investigations in space

A high-efficiency, extreme ultraviolet (EUV) imaging spectrometer has been constructed and tested. The spectrometer employs a concave toroidal grating illuminated at normal incidence in a Rowland circle mounting and has only one reflecting surface. The toroidal grating has been fabricated by a new technique employing an elastically deformable submaster grating which is replicated in a spherical form and then mechanically distorted to produce the desired aspect ratio of the toroidal surface for stigmatic imaging over the selected wavelength range. The fixed toroidal grating used in the spectrometer is then replicated from this surface. Photographic tests and initial photoelectric tests with a two-dimensional, pulse-counting detector system have verified the image quality of the toroidal grating at wavelengths near 600 A. The basic designs of two instruments employing the spectrometer for astrophysical investigations in space are described, namely, a high-resolution EUV spectroheliometer for studies of the solar chromosphere, transition region, and corona; and an EUV spectroscopic telescope for studies of nonsolar objects.

Huber, M. C. E.

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

A second toroidal replica grating was found to have an aspect ratio within 10% of the desire value. The aspect ratio of replica toroidal gratings is coming out somewhat low. Whether this is caused by some relaxation in the epoxy or some residual error in the setup when the replication is made from the deformable submaster grating will be determined. The first imaging tests at EUV wavelengths near 500 A were carried out. The initial results are most encouraging with blur sizes of the order of, or less than, 40 microns. Further focussing and additional photographic tests will be carried out, and preparations made for the first photoelectric measurements of the image quality using the (256 x 1024)-pixel MAMA detection system. The visible-light (256 x 1024)-pixel MAMA detector tube has completed initial evaluation.

Timothy, J. G.

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.

Photometry with Multi-anode Microchannel Arrays (mamas) and Charge Injection Devices (cids)

The characteristics of two kinds of detectors are summarized with emphasis on those aspects that would affect their use in high accuracy astronomical photometry. The first type, the multianode microchannel arrays (MAMA), are a family of pulse counting array detectors. Components and operation principles are reviewed and quantum efficiency, noise characteristics, and dynamic range characteristics are described. The second type, charge injection devices (CID), are discussed in reference to their applicability to photometric detection at optical wavelengths.

Timothy, J. G.

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

Two crucial areas in the development of the high resolution EUV spectroheliometer are the elastically deformable toroidal diffraction grating and the open-structure imaging pulse counting detector system. The optical performance of a high frequency toroidal grating at EUV wavelengths was verified with a 3600 groove/mm master grating on a spherical concave blank. An open-structure (256 x 1024) pixel, multi-anode microchannel array was developed and tested as a pulse counting detector system. These two systems verify the proof of concept of the spectroheliometer design.

Timothy, J. G.

Performance characteristics of multi-anode microchannel array detector systems

The multi-anode microchannel arrays (MAMAs) are state-of-the-art, pulse-counting, photoelectric array detectors designed specifically for use in space astrophysics instruments. The present paper provides a description of recent progress related to the development of ultraviolet and visible-light versions of the MAMA detectors, taking into account a comparison of the operating characteristics of these devices with those of photoconductive array detectors, such as the CCDs. Attention is given to MAMA detector system design parameters, the operating characteristics of MAMAs and CCDs, MAMA performance characteristics, and future developments.

Timothy, J. G.