Search NASASearch

Engineering topics

Timothy, J. G.

Publications and source records attributed to Timothy, J. G..

At least 55 records · Page 3

The nature of stellar active regions

Observational estimates of chromospheric radiative loss rates in Ca II H and K in main-sequence F, G, and K dwarfs are used to compare stars that span a range of activity levels with each other and with the sun. For stars with spectral types similar to that of the sun, it is found that chromospheric radiative losses in stars with active chromospheres exceed the flux emitted by plages on the sun at solar maximum by about a factor of 6. If this difference is due primarily to a difference in the fraction of the stellar surface covered by plage-like material, and not to a change in the character of the emission-line regions, then more than half of the stellar surface in stars with large chromospheric radiative loss rates must be covered by active regions. It is also possible to show that active regions in young solar-type stars extend at least to latitudes + or - 25 deg from the rotational equator and that a typical individual region contributes no more than 2 percent - 3 percent of the total H and K emission. In Kappa Cet, observations show that the rotational modulation persisted in both phase and amplitude for at least 100 days (12 rotation cycles).

Wolff, S. C.

The development and test of multi-anode microchannel array detector systems. 2: Soft X-ray detectors

The techniques and procedures for producing very-large-format pulse-counting array detector systems for use in forthcoming high-energy astrophysics facilities were defined, and the structures and performance characteristics of high-sensitivity photocathodes for use at soft X-ray wavelengths between 100 and 1 A were determined. The progress made to date in each of these areas are described and the tasks that will be undertaken when the program is continued are summarized.

Timothy, J. G.

Optical detectors for spectroscopy

The modes of operation of photoconductive and photoemissive array detectors are described, and their performance characteristics compared and contrasted, with emphasis on their suitability for use as detectors for optical spectroscopy. The prospects for future developments of the array detectors are discussed.

Timothy, J. G.

Observations of Of-star wind variability

Nightly variations in He II 4686 A have been observed in four Of stars, HD 152408, HD 151804, 9 Sge, and Lambda Cep. Three of the stars were not previously known to show such variations. In one case, Lambda Cep, simultaneous observations with IUE showed variations in ultraviolet (UV) resonance-line profiles during the same time period as those in He II 4686 A. This implies that the perturbations causing the He II 4686 A variability affect the entire wind acceleration zone.

Grady, C. A.

The measurement of solar spectral irradiances at wavelengths between 40 and 4000 A

Two 1/8-meter Ebert-Fastie spectrometers were refurbished and upgraded in order to measure the solar spectral irradiances between 1160 A and 3100 A. An evacuated 1/4-meter normal-incidence spectrometer was also fabricated for spectral irradiance measurements over the wavelength range from 1250 A to 250 A. Procedures were developed for the calibration of all three instruments utilizing standards at the National Bureau of Standards. The two 1/8-meter spectrometers were flown to measure the solar spectral irradiances near solar maximum on two different dates. Data from these flights were analyzed. The performance of the spectrometers, and the results of an analysis of the variabilities of the solar spectral irradiances over the solar cycles 20 and 21 are discussed.

Timothy, J. G.

The depletion of calcium in the Rho Ophiuchi cloud

Data on the interstellar Ca II H and K lines toward HD 147889, a star deeply embedded in the rho Ophiuchi dark cloud, were obtained at the Mauna Kea Observatory of the University of Hawaii, using a multi-anode microchannel array (MAMA) detector. An upper limit on the Ca II column density of 1.7 x 10 to the 11th/sq cm was derived, which, together with ionization considerations and an estimated lower limit on the total hydrogen column density, implies that the calcium-to-hydrogen ratio in this line of sight is 0.00000795 or less, relative to the solar value. The logarithmic depletion is up to -5.10, the largest yet measured, and implies that gas-grain interaction in this region has proceeded to a much greater degree than is typical of diffuse clouds.

Snow, T. P.

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.

He I lines in B stars - Comparison of non-local thermodynamic equilibrium models with observations

Profiles of He gamma-gamma 4026, 4387, 4471, 4713, 5876, and 6678 have been obtained in 17 stars of spectral type B0-B5. Parameters of the nonlocal thermodynamic equilibrium models appropriate to each star are determined from the Stromgren index and fits to H-alpha line profiles. These parameters yield generally good fits to the observed He I line profiles, with the best fits being found for the blue He I lines where departures from local thermodynamic equilibrium are relatively small. For the two red lines it is found that, in the early B stars and in stars with log g less than 3.5, both lines are systematically stronger than predicted by the nonlocal thermodynamic equilibrium models.

Heasley, J. N.

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.

A search for diffuse band profile variations in the rho Ophiuchi cloud

High signal-to-noise profiles of the broad diffuse interstellar band at 4430 A were obtained on the 2.2-m telescope at the Mauna Kea Observatory, using the newly-developed pulse-counting multi-anode microchannel array detector system in an effort to determine whether the band profile varies with mean grain size as expected if the band is produced by absorbers embedded in grain lattices. The lack of profile variability over several lines of sight where independent evidence indicates that the mean grain size varies shows that lambda 4430 is probably not formed by the same grains that are responsible for interstellar extinction at visible wavelengths. The possibility that this band is created by a population of very small ( approximately 100 A) grains is still viable, as is the hypothesis that it has a molecular origin.

Snow, T. P.

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.

High-resolution spectroscopy with the multi-anode microchannel array detector systems

The results of a series of high-resolution spectroscopic observations undertaken with a linear (1 x 1024)-pixel visible-light Multi-Anode Microchannel Array (MAMA) detector on the Coudespectrograph of the 2.2-meter telescope at the Mauna Kea Observatory and on the vacuum spectrograph of the McMath Solar telescope at the Kitt Peak National Observatory are described. In addition, the two-dimensional MAMA detector systems with (16 x 1024)-pixel, (24 x 1024)-pixel, and (256 x 1024)-pixel formats which are now being readied for use in a series of ground-based, balloon, and sounding-rocket observing programs are briefly described.

Timothy, J. G.

Speckle spectroscopy; an application for the multi-anode microchannel array detector system

Plans to combine the High Angular Resolution Imager/Spectrometer on the 4-meter Mayall telescope at the Kitt Peak National Observatory and the (256 x 1024)-pixel Multi-Anode Microchannel Array detector system to produce a unique instrument for speckle spectroscopy are described. The pulse-counting detector system will provide distortion-free imaging and will time tag each spatially-resolved photon event with an accuracy of 100 ns. The Imager/Spectrometer will provide a spatial resolution of 0.07 arcsec orthogonal to the plane of dispersion and 0.18 arcsec in the plane of dispersion.

Butcher, H. R.

Curved-channel microchannel array plates

The microchannel array plate (MCP) is a photoelectric detector with an imaging capability comparable to that of a photographic plate. Recently MCPs in which the channels are curved to inhibit ion feedback have become available. These devices represent a major advance in MCP technology, since a single curved-channel MCP can be operated stably at high gain in the pulse-counting mode without any of the problems of stability of response or short lifetime reported for 'chevron' MCP detectors. Attention is given to the mode of operation of channel electron multipliers (CEM) and MCP, curved-channel MCP, test procedures, and performance characteristics. The accumulated test data show that the fundamental operating characteristics of the curved-channel MCP are directly related to those for the CEM.

Timothy, J. G.

Multianode microchannel array detectors for Space Shuttle imaging applications

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric, photoncounting array detectors that have been developed and qualified specifically for use in space. MAMA detectors with formats as large as 256 x 1024 pixels are now in use or under construction for a variety of imaging and tracking applications. These photo-emissive detectors can be operated in a windowless configuration at extreme ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. The construction and modes-of-operation of the MAMA detectors are briefly described and the scientific objectives of a number of sounding rocket and Space Shuttle instruments utilizing these detectors are outlined. Performance characteristics of the MAMA detectors that are of fundamental importance for operation in the Space Shuttle environment are described and compared with those of the photo-conductive array detectors such as the CCDs and CIDs.

Timothy, J. G.

Photoelectric array detectors for use at XUV wavelengths

The characteristics of photoelectric detector systems for use at visible-light, ultraviolet, and X-ray wavelengths are briefly reviewed in the context of the needs of the Spacelab solar-physics facilities. Photoelectric array detectors for use at XUV wavelengths between 90 and 1500 A are described, and their use in the ESA Grazing-Incidence Solar Telescope (GRIST) facility is discussed.

Timothy, J. G.

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.