Search NASASearch

Engineering topics

Timothy, J. G.

Publications and source records attributed to Timothy, J. G..

At least 73 records · Page 4

The solar spectral irradiance 1200-2550 A at solar maximum

Full-disk solar spectral irradiances at solar maximum were obtained in the spectral range 1200-2550 A at a spectral resolution of approximately 1 A from rocket observations above White Sands, New Mexico, on June 5, 1979. Comparison with measurements made near solar minimum indicates approximately a factor of 2.5 increase in the irradiance at 1200 A, a 20% increase near 1800 A, and no increase within our measurement errors (+ or - 15%) above 2100 A. Irradiances in the range 1800-2100 A are in excellent agreement with previous measurements, but those in the 2100- to 2550-A range are significantly lower. The intensities of strong emission lines at wavelengths below 1850 A are also reported.

Mount, G. H.

The variability of the solar ultraviolet spectral irradiances

Available data on the solar spectral irradiances at wavelengths below 3100 A are extremely limited and there are major uncertainties in many of the measurements. In particular, there is major disagreement on the magnitude of the variability of the spectral irradiances over the solar cycle. The effects of different solar features on the ultraviolet spectral irradiances over both the 28 day solar rotation period and over the solar cycle are discussed. It is proposed that any attempt to predict the magnitudes of the ultraviolet spectral irradiances must take into account a long term variability of emission from quiet regions of the solar disk over the solar cycle. The need for direct long term monitoring of the ultraviolet spectral irradiances is emphasized.

Timothy, J. G.

Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube

A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.

Timothy, J. G.

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.

Performance characteristics of high-conductivity channel electron multipliers

The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

Timothy, J. G.

A progress report on multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are briefly described.

Timothy, J. G.

Optical design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena at extreme-ultraviolet wavelengths

The design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena in the solar atmosphere at extreme ultraviolet (EUV) wavelengths is described. The normal-incidence spectrometer requires only one reflective surface, and is equipped with a series of exit slits and associated one-dimensional detector arrays that are mounted at the secondary (vertical) foci of the concave diffraction grating. It is shown that such a spectrometer mounted at the focus of an off-axis paraboloid telescope mirror of the size employed in the EUV spectroheliometer flown on Skylab could record monochromatic images of a 2 x 2 (arcmin) sq field-of-view with a spatial resolution element of 1 x 1 (arcsec) sq in a time of 4 s, 24 s, or 4 min, depending on whether the region studied is flaring, active, or quiet. The resulting spectroheliograms would have an average photometric precision of 10% and a spectral purity of 0.1 A.

Huber, M. C. E.

Extreme UV spectroheliometer on the Apollo Telescope Mount

The extreme UV spectroheliometer flown on ATM observed within the 280-1340 A spectral range at seven wavelengths simultaneously, with a spatial resolution element 5 x 5 sq arcsec field of view in 5.5 min. The instrument could also obtain spectral scans over the same wavelength range with a spectral resolution of 1.6 A in 3.8 min. The instrument is described in detail with attention given to the telescope, the spectrometer, and the detection system.

Reeves, E. M.

Photometric calibration of the EUV spectroheliometer on ATM

This paper describes the derivation of the preflight photometric calibration of the UV spectrometer on Skylab. The calibration of the orbiting instrument through cross-comparison with two rocket instruments is discussed in assessing the observed changes in response to quiet solar regions during the mission. Formulas are presented for the determination of the instrument sensitivity, and an uncertainty of plus or minus 35% is assigned over most of the 296-1340-A wavelength range.

Reeves, E. M.

Preliminary results with microchannel array plates employing curved microchannels to inhibit ion feedback

Up to now, microchannel array plates (MCPs) have been constructed with microchannels having a straight geometry and hence have been prone to ion-feedback instabilities at high operating potentials and high ambient pressures. This paper describes the performances of MCPs with curved (J and C configuration) microchannels to inhibit ion feedback. Plates with curved microchannels have demonstrated performances comparable to those of conventional channel electron multipliers with saturated output pulse-height distributions and modal gain values in excess of 10 to the 6th electrons/pulse.

Timothy, J. G.

Multi-anode microchannel arrays

A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.

Timothy, J. G.

Development and test of photon-counting microchannel plate detector arrays for use on space telescopes

The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.

Timothy, J. G.

Instrumentation for solar spectrophotometry at extreme ultraviolet and soft X-ray wavelengths

The solar extreme ultraviolet and soft X-ray (XUV) spectrum at wavelengths between 20 and 300 A contains a wealth of emission lines from ions formed at temperatures from 10 to the 5th K to greater than 2 x 10 to the 7th K. The requirements for high resolution spectrophotometric instrumentation are discussed in the light of data obtained with extreme ultraviolet and X-ray telescopes flown on Skylab. The design of a grazing-incidence spectroheliometer for active region and flare studies over the wavelength range from 40 to 630 A is presented and recently developed high-efficiency detectors and detector-arrays for use at XUV wavelengths are described.

Timothy, J. G.

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.

Two-dimensional photon detector

Device incorporates set of cascaded microchannel-array plates in proximity focus with two sets of mutually-orthogonal linear anodes. Technique allows data from N x M picture elements to be recorded with only N + M amplifiers.

Timothy, J. G.