Search NASA⌕ Search

Engineering topics

Trang-Le, Truc L.T.

Publications and source records attributed to Trang-Le, Truc L.T..

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗