Search NASA⌕ Search

Engineering topics

Tuffner, Francis K.

Publications and source records attributed to Tuffner, Francis K..

At least 55 records · Page 3

Improving Primary Frequency Response in Networked Microgrid Operations using Multilayer Perceptron-Driven Reinforcement Learning

Individual microgrids can improve the reliability of power grids during extreme events, and networked microgrids can further improve efficiency through resource sharing and increase the resilience of critical end-use loads. However, networked microgrid operations are subject to large switching transients, which can cause dynamic instability and lead to system collapse. These transients are especially prevalent in microgrids with high penetrations of inverter-connected renewable energy resources, which do not provide the system inertia needed to mitigate the transients. Existing generator controls can be modified to invoke a drop in terminal voltage in response to a frequency deviation, thereby reducing load and improving frequency response. This paper investigates the use of a reinforcement-learning--based controller trained over several switching transient scenarios to modify generator controls during large frequency deviations. Compared to previously used proportional integral controllers, the proposed controller can improve primary frequency response while adapting to changes in system topologies and events.

Radhakrishnan, Nikitha↗

Studying impacts of communication system performance on dynamic stability of networked microgrid

The development of smart grid technologies has resulted in increased interdependence between power and communication systems. Many of the operations in the existing power system rely on a stable and secured communication system. For electrically weak systems and time‐critical applications, this reliance can be even greater, where a small degradation in communication performance can degrade system stability. However, despite inter‐dependencies between power and communication systems, only a few studies have investigated the impacts of communication system performance on power system dynamics. This study investigates the dependencies of power system dynamics operations on a communication system performance. First, a detailed, dynamic networked microgrid model is developed in the GridLAB‐D simulation environment, along with a representative multi‐traffic, multi‐channel, multi‐protocol communication system model, developed in the network simulator (ns‐3). Second, a hierarchical engine for large‐scale infrastructure co‐simulation framework is developed to co‐simulate microgrid dynamics, its communication system, and a microgrid control system. The impact of communication system delays on the dynamic stability of networked microgrids is evaluated for the loss of generation using three use‐cases. While the example use‐cases examine microgrid applications and the impact to resiliency, the framework can be applied to all levels of power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Design Process for Networked Microgrids

Changes in economic, technology, and environmental policies are resulting in a re-evaluation of the dependence on large central generation facilities and their associated transmission networks. Emerging concepts of smart communities/cities are examining the potential to leverage cleaner sources of generation, and the potential to integrate electricity generation with other municipal functions. When grid-connected, these generation assets can supplement the existing interconnections with the bulk transmission system, and in the event of an extreme event, they can provide power via networks of microgrids. While the design process for a single stand-alone microgrid is relatively well understood, the process of designing the infrastructure for networked microgrid operations has not been well studied. Because of the wide range of potential operational goals for microgrids, it is typical to follow the engineering process of developing an initial conceptual design, a preliminary design, a detailed design, and then a final as-built design. The conceptual design is typically completed without detailed engineering analysis, and the preliminary design is the first stage that requires it. This paper presents a process for developing the preliminary design for networked microgrids, which can then be used as a basis for the final as-built design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Cloud-based Performance of Distribution Planning - Improvements to GridLAB-D

This report provides a high-level summary of the improvements to the GridLAB-D distribution analysis software, including work with GridUnity to focus the areas of improvement and test the final implementation. The improvements allow repetitive, time-series-based simulations, such as renewable hosting capacity studies, to show a 30% or more improvement in execution time. All improvements from this project are available on GridLAB-D’s open-source repository, with most of the changes migrated into the upcoming version 4.3 release of the software.

97 MATHEMATICS AND COMPUTING↗

Microgrid Stability Definitions, Analysis, and Examples

This document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid Stability Definitions, Analysis, and Modeling [1], which defines concepts and identifies relevant issues related to stability in microgrids. In this paper, definitions and classification of microgrid stability are presented and discussed, considering pertinent microgrid features such as voltage-frequency dependency, unbalancing, low inertia, and generation intermittency. A few examples are also presented, highlighting some of the stability classes defined in the paper. Further examples, along with discussions on microgrid components modeling and stability analysis tools can be found in the TF report.

Farrokhabadi, Mostafa↗

A Comparative Study of Two Widely Used Grid-Forming Droop Controls on Microgrid Small Signal Stability

Throughout history, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.

42 ENGINEERING↗

Modeling of Grid-Forming Inverters for Transient Stability Simulations of an all Inverter-based Distribution System

Existing models of grid-forming inverters are typically three-phase electromagnetic models and positive sequence electromechanical models. Both of them are not suitable for dynamic simulations of large scale three-phase unbalanced distribution systems. In order to investigate grid-forming inverters’ impact on the transient stability of large scale three-phase unbalanced distribution systems, a dynamic model of a grid-forming inverter is developed and implemented in an open-source GridLAB-D simulation environment. The advantage of this method is that it can be extended to full-size three-phase unbalanced distribution systems. Simulation results of an all grid-forming inverter-based modified version of IEEE 123-node distribution system verify the capability of grid-forming inverters to maintain the transient stability of a resilient distribution system.

Grid-forming, Inverter, Distribution System, Trans↗

Modeling Load Dynamics to Support Resiliency-based Operations in Low-Inertia Microgrids

Microgrids have repeatedly demonstrated the ability to provide uninterrupted service to critical end-use loads during normal outages, severe weather events, and natural disasters. While their ability to provide critical services is well documented, microgrids present a more dynamic operational environment than grid-connected distribution systems. The dynamics of a microgrid are commonly driven by the high inertia of rotating generators, which are common in many microgrids. In such high-inertia systems, the impact of end-use load dynamics are often not examined. However, with the increased penetration of inverter-based generation with little or no inertia, it is necessary to consider the impact that the dynamics of the end-use loads have on the operations of microgrids, particularly for a resiliency-based operation. These operations include, but are not limited to, switching operations, loss of generating units, and the starting of induction motors. This paper examines the importance of including dynamic models of the end-use load when evaluating the operations of low inertia microgrids, and shows that by properly representing their behavior, it is possible to cost effectively size equipment while supporting resilient operations of critical end-use loads.

Tuffner, Francis K.↗

Identifying Parameter Space for Robust Stability in Nonlinear Networks: A Microgrid Application

As modern engineering systems grow in complexity, attitudes toward a modular design approach become increasingly more favorable. A key challenge to a modular design approach is the certification of robust stability under uncertainties in the rest of the network. In this paper, we consider the problem of identifying the parametric region, which guarantees stability of the connected module in the robust sense under uncertainties. We derive the conditions under which the robust stability of the connected module is guaranteed for some values of the design parameters, and present a sum-of-squares (SOS) optimization-based algorithm to identify such a parametric region for polynomial systems. Using the example of an inverter-based microgrid, we show how this parametric region changes with variations in the level of uncertainties in the network.

Kundu, Soumya↗

DGs for Service Restoration to Critical Loads in a Secondary Network

During a major outage in a secondary network distribution system, distributed generators (DGs) connected to the primary feeders as well as the secondary network can be used to serve critical loads. This paper proposed a resilience-oriented method to determine restoration strategies for secondary network distribution systems after a major disaster. Technical issues associated with the restoration process are analyzed, including the operation of network protectors, inrush currents caused by the energization of network transformers, synchronization of DGs to the network, and circulating currents among DGs. A look-ahead load restoration framework is proposed, incorporating technical issues associated with secondary networks, limits on DG capacity and generation resources, dynamic constraints, and operational limits. The entire outage duration is divided into a sequence of periods. Restoration strategies can be adjusted at the beginning of each period using the latest information. Numerical simulation of the modified IEEE 342-node low voltage networked test system is performed to validate the effectiveness of the proposed method.

Xu, Yin (ORCID:0000000209459024)↗

Advanced Reconfiguration and Protection of Distribution Systems: Four Areas of Supporting Research

Historically, distribution systems have been very susceptible to transmission- and distribution-level events, such as line trips and faults within substations, because local sources of energy, if available at all, were only designed to operate in the context of a fully functional grid. However, the increasing deployment of advanced measuring devices, distributed energy resources (DERs), and energy storage provide the opportunity to improve reliability at the distribution level using advanced measurement-based reconfiguration and protection methods. This report discusses research regarding 1) a transmission equivalent model, 2) an algorithm for distinguishing between transmission- and distribution-level events, 3) a spreadsheet to help site new measurement devices, and 4) network theory to enable smart reconfiguration of distribution systems. Each of these areas of research support the development and study of advanced reconfiguration and protection methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning of Factors Influencing Damping and Frequency of Dominant Inter-area Modes in the WECC Interconnect

The stability of inter-area electromechanical oscillations are critical to power system reliability. Due to the complexities of power systems, relationships between system conditions and oscillation characteristics, such as damping and frequency, tend to be expressed only in generalities. In this study, a list of influential factors on Western Electricity Coordinating Council (WECC) interconnect modal characteristics are identified and evaluated with advanced machine learning techniques including principal component analysis, analysis of variance, random forest feature selection, support vector machine, and artificial neural network approaches.

Hou, Zhangshuan↗

Open-Source Suite for Advanced Synchrophasor Analysis

The paper presents the results of the development of the open-source suite of applications for synchrophasor analysis. The suite includes several software tools for oscillation analysis, power plant model validation, and frequency response analysis using synchrophasor measurements. All tools are based on the common framework and data sources. The developed tools have been used by the Bonneville Power Administration and other utilities for synchrophasor analysis. The paper includes several use cases based on the actual system PMU data.

PMU, model validation, Oscillation Modes, Open Sou↗

Grid Friendly Appliance Controllers to Increase the Dynamic Stability of Networked Resiliency-based Microgrids

Microgrids provide the ability to maintain service to critical end-use loads when utility service is not available. Despite their ability to increase resiliency, they can have high capital and operating costs; this can be compounded by the complexities associated with low inertia systems. One option to mitigate the costs is to more effectively engage the assets within the microgrids, specifically the end-use loads. Previous work has shown that by using Grid Friendly™ Appliance controllers, it is possible to increase the dynamic stability of multiple microgrids during switching transients, without the need to oversize generation assets or to install energy storage devices. Building on the previous work, this paper will present a method for determining the set-points of decentralized controllers, accounting for the different characteristics and sizes of loads, to facilitate multiple microgrid switching operations. By effectively engaging the end-use load as a resource, the switching operations necessary to network low inertia microgrid for resiliency applications can be supported without the need to oversize generation assets or for energy storage.

GridLAB-D, Distribution Analysis↗

Evaluating the Loss of Communications in Distribution Protection Systems using GridLAB-D

Protection in distribution systems is vital for maintaining reliability and ensuring proper power quality is provided to the end-use customer. As more switching devices are deployed on distribution systems, traditional protection schemes are giving way to more advanced, and sometimes centrally coordinated, protection schemes that rely on communications infrastructure. With these communications-dependent systems, the behaviors of the protection with and without the communications infrastructure must be examined. This work has evaluated the impacts of loss of communication in centrally coordinated protection schemes. Two test cases were examined: a sequence of similar faults on a feeder before and after a topology reconfiguration, and a feeder with a photovoltaic (PV) fault current contribution. Both simulations are run in the GridLAB-D™ simulation environment. A simple connectivity model is used to represent communication status. The results reveal that a failure of the communication system can cause significantly different protection behavior. This analysis can be used as a basis for utility engineers to make an informed decision on the impacts of communication losses on their system, as well as evaluating ways to mitigate its impact on the resiliency of the system.

GridLAB-D, Distribution Analysis↗

Microgrids for Service Restoration to Critical Load in a Resilient Distribution System

icrogrids can act as emergency sources to serve critical loads when utility power is unavailable. This paper proposes a resiliency-based methodology that uses microgrids to restore critical loads on distribution feeders after a major disaster. Due to limited capacity of distributed generators (DGs) within microgrids, dynamic performance of the DGs during the restoration process becomes essential. In this paper, the stability of microgrids, limits on frequency deviation, and limits on transient voltage and current of DGs are incorporated as constraints of the critical load restoration problem. The limits on the amount of generation resources within microgrids are also considered. By introducing the concepts of restoration tree and load group, restoration of critical loads is transformed into a maximum coverage problem, which is a linear integer program (LIP). The restoration paths and actions are determined for critical loads by solving the LIP. A 4-feeder, 1069-bus unbalanced test system with four microgrids is utilized to demonstrate the effectiveness of the proposed method. The method is applied to the distribution system in Pullman, WA, resulting in a strategy that uses generators on the Washington State University campus to restore service to the Hospital and City Hall in Pullman.

Xu, Yin (ORCID:0000000209459024)↗