Search NASA⌕ Search

Engineering topics

Vaidhynathan, Deepthi

Publications and source records attributed to Vaidhynathan, Deepthi.

At least 19 records

Fuel Cell Inverter Dataset

This data set contains the three phase AC voltage, three phase AC current, DC voltage and DC current. These data sets were captured during fuel cell inverter operation in grid-connected dispatch, islanded load changes, transition from grid-connected mode to islanded mode and vice-versa.

25 ENERGY STORAGE↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Memory access optimization for particle operations in computational fluid dynamics-discrete element method simulations

Computational Fluid Dynamics - Discrete Element Method is used to model gas-solid systems in several applications in energy, pharmaceutical and petrochemical industries. Computational performance bottlenecks often limit the problem sizes that can be simulated at industrial scale. The data structures used to store several millions of particles in such large-scale simulations have a large memory footprint that does not fit into the processor cache hierarchies on current high-performance-computing platforms, leading to reduced computational performance. This paper specifically addresses this aspect of memory access bottlenecks in industrial scale simulations. The use of space-filling curves to improve memory access patterns is described and their impact on computational performance is quantified in both shared and distributed memory parallelization paradigms. The Morton space filling curve applied to uniform grids and k-dimensional tree partitions are used to reorder the particle data-structure thus improving spatial and temporal locality in memory. The performance impact of these techniques when applied to two benchmark problems, namely the homogeneous-cooling-system and a fluidized-bed, are presented. We report these optimization techniques lead to approximately two-fold performance improvement in particle focused operations such as neighbor-list creation and data-exchange, with ~ 1.5 times overall improvement in a fluidization simulation with 1.27 million particles.

97 MATHEMATICS AND COMPUTING↗

ParaEMT (NLR's (formerly known as NREL's) EMT Simulator: An Open Source, and HPC-Compatible Large-Scale Power System Electro-Magnetic Transient (EMT) Simulator) [SWR-22-16]

This open-source tool aims to provide a powerful and flexible platform for simulating electromagnetic transients (EMT) of large-scale inverter-based resource (IBR)-dominated power systems. The purpose of making it open source is to foster a community of EMT simulation and assist in exploring new EMT algorithms and applying advanced computational techniques to EMT simulation.

Tan, Jin↗

MFIX DEM Enhancement for Industry-Relevant Flows (Final Report)

The overall goal of this two-phase project is to implement performance improvements of the Multiphase Flow with Interphase Exchanges (MFIX) Discrete Element Model (DEM) code that enable a transformative shift for industrial use. Prior to this effort, the largest simulations performed using MFIX are O(10 7 ) particles. This falls short of the O(10 9 ) particle simulations that must be completed on a timescale of days or weeks (vs. months or years) to enable simulations with physically-relevant domain sizes to be incorporated into industrial design cycles within five years. This was accomplished by tailoring best-in-class practices to bear on the unique challenges posed by the MFIX-DEM algorithm and code base. Scientific simulations (e.g., in cosmology, turbulent combustion) routinely use massively parallel computing to update far more particles in short wall clock times. Results from Phase 1 (1.5 years in duration) indicated significant gains in speed were possible for a wide range of benchmark cases. Moreover, a survey sent to >35 companies indicates that the timing is ideal for such an enhanced tool, with >80% of the respondents indicating that DEM is already value-added or will be within the next 5 years, and >70% of the respondents indicating that improved speed is the top computational priority. In Phase 2 (3.5 years in duration), the two major barriers that hinder industry from effectively using multiphase Computational Fluid Dynamics (CFD) to cut costs and improve performance, namely computational overhead and confidence in predictions, continued to be addressed. Regarding the former, the results from Phase 1 to guide the effort, with enhancements focused on an improved time-stepping algorithm and particle sorting. Four target problems of 1 billion particles each and increasing complexity were identified: homogeneous cooling, tumbler with continuous particle size distribution, discharge from a rectangular hopper and a cylindrical riser. Each of these were successfully simulated for relevant time scales (on order of seconds) using less than 24 hours of wall clock time. These represent the first 1-billion particle DEM simulations performed with MFIX, namely using the MFIX-Exa code. This code is currently under development at NETL in collaboration with Lawrence Berkeley National Laboratory. Regarding the second barrier on predictive uncertainty, experiments from Phase 1 (interacting nozzles - hydrodynamics only) and Phase 2 (very small-scale segregation experiments) were used to demonstrate the ability of two simplified approaches to uncertainty quantification (UQ). By limiting the number of particles, UQ based on the simplified treatment was compared to standard UQ, which was shown to have much higher computational demands. Experiments were also performed on a pilot-scale stripper unit to provide validation data for future CFD-DEM simulations and UQ.

20 FOSSIL-FUELED POWER PLANTS↗

PowerGridworld: A Framework for Multi-Agent Reinforcement Learning in Power Systems [SWR-22-07]

NREL's PowerGridworld provides a modular simulation environment for training heterogenous, grid-aware, multi-agent reinforcement learning (RL) policies at scale. The package enables the user to create component gym environments that can be composed into more complex agents. For example, a grid interactive building environment can be created by composing together component environments each encapsulating the building, PV, and battery physics. These multi-component environments can then be combined into multi-agent simulation where each agent's power consumption/injection becomes an input for solving the optimal power flow on a distribution feeder modeled in OpenDSS. Information from OpenDSS, such as bus voltages and line flows, can be included in the agents' observation spaces to enable grid-aware rewards. The default API for the PowerGridworld simulator conforms to RLLib's MultiAgent API and thus enables distributed training using HPC and cloud resources.

Biagioni, David↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

SCC (Step characteristics calculator) [SWR-21-80]

The SCC software calculates the step response characteristics based on the data collected from the plant. The tools available to characterize the step response needs a plant model. Our tool calculates the characteristics based on the data captured from the plant. This prevents the user from building a plant model and directly calculates the response.

Prabakar, Kumaraguru↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

On the Computational Viability of Quantum Optimization for PMU Placement

Using optimal phasor measurement unit placement as a prototypical problem, we assess the computational viability of the current generation D-Wave Systems 2000Q quantum annealer for power systems design problems. We reformulate minimum dominating set for the annealer hardware, solve the reformulation for a standard set of IEEE test systems, and benchmark solution quality and time to solution against the CPLEX optimizer and simulated annealing. For some problem instances the 2000Q outpaces CPLEX. For instances where the 2000Q underperforms with respect to CPLEX and simulated annealing, we suggest hardware improvements for the next generation of quantum annealers.

hardware↗