Detecting non-Maxwellian electron velocity distributions at JET by high resolution Thomson scattering

The present work is motivated by a long standing discrepancy between the electron temperature measurements of Thomson scattering (TS) and electron cyclotron emission (ECE) diagnostics for plasmas with strong auxiliary heating observed at both JET and TFTR above 6-7 keV, where in some cases the ECE electron temperature measurements can be 15%-20% higher than the TS measurements. Recent analysis based on ECE results at JET has shown evidence of distortions to the Maxwellian electron velocity distribution and a correlation with the TS and ECE discrepancies has been suggested. In this paper, a technique to determine the presence of non-Maxwellian behavior using TS diagnostics is outlined. The difficulties and limitations of modern TS system designs to determine the electron velocity distribution are also discussed. It is demonstrated that small deviations such as those suggested by previous ECE analysis could be potentially detected, depending on the spectral layout of the TS polychromators. The spectral layout of the JET high resolution Thomson scattering system is such that it could be used to determine these deviations between 1 and 6 keV, and the results presented here indicate that no evidence of non-Maxwellian behavior is observed in this range. In this paper, a modification to the current polychromator design is proposed, allowing non-Maxwellian distortions to be detected up to at least 10 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a full profile sub-cm ruby laser based Thomson scattering system for MAST

A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent measurements of the electron temperature and density profile. This paper focuses on the recent upgrades to the ruby TS system. The upgraded ruby TS system measures 512 points across the major radius of the MAST vessel. The ruby laser can deliver one 10 J 40 ns pulse at 1 Hz or two 5 J pulses separated by 100-800 {mu}s. The Thomson scattered light is collected at F/15 over 1.4 m. This system can resolve small (7 mm) structures at 200 points in both the electron temperature and density channels at high optical contrast; {approx}50% modulated transfer function. The system is fully automated for each MAST discharge and requires little adjustment. The estimated measurement error for a 7 mm radial point is <4% of T{sub e} and <3% of n{sub e} in the range of 40 eV to 2 keV, for a density of n{sub e}=2x10{sup 19} m{sup -3}. The photon statistics at lower density can be increased by binning in the radial direction as desired. A new intensified CCD camera design allows the ruby TS system to take two snapshots separated with a minimum time of 230 {mu}s. This is exploited to measure two density and temperature profiles or to measure the plasma background light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser system for high resolution Thomson scattering diagnostics on the COMPASS tokamak

A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 130 point Nd:YAG Thomson scattering diagnostic on MAST

A Thomson scattering diagnostic designed to measure both edge and core physics has been implemented on MAST. The system uses eight Nd:YAG lasers, each with a repetition rate of 30 Hz. The relative and absolute timing of the lasers may be set arbitrarily to produce fast bursts of measurements to suit the time evolution of the physics being studied. The scattered light is collected at F/6 by a 100 kg six element lens system with an aperture stop of 290 mm. The collected light is then transferred to 130 polychromators by 130 independent fiber bundles. The data acquisition and processing are based on a distributed computer system of dual core processors embedded in 26 chassis. Each chassis is standalone and performs data acquisition and processing for five polychromators. This system allows data to be available quickly after the MAST shot and has potential for real-time operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of development of Thomson scattering diagnostic system on COMPASS

A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiband reflectometry system for density profile measurement with high temporal resolution on JET tokamak

A new system has been installed on the JET tokamak consisting of six independent fast-sweeping reflectometers covering four bands between 44 and 150 GHz and using orthogonal polarizations. It has been designed to measure density profiles from the plasma edge to the center, launching microwaves through 40 m of oversized corrugated waveguides. It has routinely produced density profiles with a maximum repetition rate of one profile every 15 {mu}s and up to 100 000 profiles per pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of canonical profiles transport model to the H-mode shots in tokamaks

The linear and nonlinear versions of the Canonical Profiles Transport Model (CPTM), which includes both heat and particle transport equations, are used to simulate core and pedestal plasma for JET, and MAST H-mode shots. Simulations by the nonlinear version show reasonable agreement with experiment for both ELMy and ELM-free shots. RMS deviations of calculated results from the experimental ones are on the level 10-12% in main. The calculated ion and electron temperature profiles are very insensitive to the change of the deposited peaked power profiles. The calculated pedestal temperature rapidly increases with plasma current; density profile peaking increases at low collisionalities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ab initio modeling of the motional Stark effect on MAST

A multichord motional Stark effect (MSE) system has recently been built on the MAST tokamak. In MAST the {pi} and {sigma} lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch angle over the observation volume. The measured polarization angle does not relate to one local pitch angle but to an integration over all pitch angles in the observation volume. The velocity distribution of the neutral beam further complicates the measurement. To take into account volume effects and velocity distribution, an ab initio code was written that simulates the MSE spectrum on MAST. The code is modular and can easily be adjusted for other tokamaks. The code returns the intensity, polarized fraction, and polarization angle as a function of wavelength. Results of the code are presented, showing the effect on depolarization and wavelength dependence of the polarization angle. The code is used to optimize the design and calibration of the MSE diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of the JET edge LIDAR Thomson scattering diagnostic with ultrafast detectors

The edge light detection and ranging (LIDAR) Thomson scattering diagnostic at the Joint European Torus fusion experiment uses a 3 J ruby laser to measure the electron density and temperature profile at the plasma edge. The original system used a 1 GHz digitizer and detectors with response times of {approx_equal}650 ps and effective quantum efficiencies <7%. This system has recently been enhanced with the installation of a new 8 GHz digitizer and four new ultrafast GaAsP microchannel plate photomultiplier tube detectors with response times of <300 ps and effective quantum efficiencies in the range of {approx}13%-20% (averaged over {lambda}=500-700 nm). This upgrade has enabled the spatial resolution to be reduced to {approx}6.3 cm along the laser line of sight for a laser pulse of 300 ps full width at half maximum, which is close to the requirements for the ITER core LIDAR. Performance analysis shows that the new system will have an effective spatial resolution of up to 1 cm in the magnetic midplane via magnetic flux surface mapping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER LIDAR performance analysis

The core LIDAR Thomson scattering for ITER is specified for core profile measurements with a spatial resolution of 7 cm (a/30) for the range of 500 eV<T{sub e}<40 keV and n{sub e}>3x10{sup 19} m{sup -3} at an accuracy of <10% for T{sub e}. These specifications are verified using a full profile Monte Carlo simulation code. In the simulations it is assumed that the input transmission is 50% and the collection transmission is 10% for {lambda}=300-1200 nm and F/=6-17. A crucial design decision lies on the choice of laser and detector combination. It is evaluated that the system can meet its spatial and accuracy specifications for higher temperatures of T{sub e}>5 keV with a combination of a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ({lambda}{sub 0}=1064 nm, {delta}{lambda}<1 nm, 5 J, and {delta}t{sub FWHM}=250 ps, 5-10 Hz) and S20, GaAs, and GaAsP microchannel plate photomultipliers ({delta}t{sub FWHM}<300 ps, effective quantum efficiency, EQE=3%-4%, and D=18 mm). In order to reach the required T{sub e} of 500 eV with Nd:YAG first harmonic, this choice requires a development of fast near infrared detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a new Nd:YAG Thomson scattering system for MAST

A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with {approx_equal}10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 over scattering angles ranging from 80 deg. to 120 deg. The laser energy and lens size, relative to an existing 1.2 J f/12 system, greatly increases the number of scattered photons collected per unit length of laser beam. This is the third generation of this polychromator to be built and a number of modifications have been made to facilitate mass production and to improve performance. Detected scattered signals will be digitized at a rate of 1 GS/s by 8 bit analog to digital converters (ADCs.) Data may be read out from the ADCs between laser pulses to allow for real-time analysis.