Search NASA⌕ Search

Engineering topics

Wang, P

Publications and source records attributed to Wang, P.

At least 19 records

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-06: Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques

Purpose: Cone-beam (CB) computed tomography (CT) is used for image guidance during radiotherapy treatment delivery. Conventional Feldkamp and compressed sensing (CS) based CBCT recon-struction techniques are compared for image registration. This study is to evaluate the image registration accuracy of conventional and CS CBCT for head-and-neck (HN) patients. Methods: Ten HN patients with oropharyngeal tumors were retrospectively selected. Each HN patient had one planning CT (CTP) and three CBCTs were acquired during an adaptive radiotherapy proto-col. Each CBCT was reconstructed by both the conventional (CBCTCON) and compressed sens-ing (CBCTCS) methods. Two oncologists manually labeled 23 landmarks of normal tissue and implanted gold markers on both the CTP and CBCTCON. Subsequently, landmarks on CTp were propagated to CBCTs, using a b-spline-based deformable image registration (DIR) and rigid registration (RR). The errors of these registration methods between two CBCT methods were calcu-lated. Results: For DIR, the mean distance between the propagated and the labeled landmarks was 2.8 mm ± 0.52 for CBCTCS, and 3.5 mm ± 0.75 for CBCTCON. For RR, the mean distance between the propagated and the labeled landmarks was 6.8 mm ± 0.92 for CBCTCS, and 8.7 mm ± 0.95 CBCTCON. Conclusion: This study has demonstrated that CS CBCT is more accurate than conventional CBCT in image registration by both rigid and non-rigid methods. It is potentially suggested that CS CBCT is an improved image modality for image guided adaptive applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-07: Implementation of a Pulsed Low Dose Date Radiotherapy (PLRT) Protocol for Recurrent Cancers Using Advanced Beam Delivery

Purpose: Recent in vitro and in vivo experimental findings provided strong evidence that pulsed low-dose-rate radiotherapy (PLDR) produced equivalent tumor control as conventional radiotherapy with significantly reduced normal tissue toxicities. This work aimed to implement a PLDR clinical protocol for the management of recurrent cancers utilizing IMRT and VMAT. Methods: Our PLDR protocol requires that the daily 2Gy dose be delivered in 0.2Gy×10 pulses with a 3min interval between the pulses. To take advantage of low-dose hyper-radiosensitivity the mean dose to the target is set at 0.2Gy and the maximum dose is limited to 0.4Gy per pulse. Practical planning strategies were developed for IMRT and VMAT: (1) set 10 ports for IMRT and 10 arcs for VMAT with each angle/arc as a pulse; (2) set the mean dose (0.2Gy) and maximum dose (0.4Gy) to the target per pulse as hard constraints (no constraints to OARs); (3) select optimal port/arc angles to avoid OARs; and (4) use reference structures in or around target/OARs to reduce maximum dose to the target/OARs. IMRT, VMAT and 3DCRT plans were generated for 60 H and N, breast, lung, pancreas and prostate patients and compared. Results: All PLDR treatment plans using IMRT and VMAT met the dosimetry requirements of the PLDR protocol (mean target dose: 0.20Gy±0.01Gy; maximum target dose < 0.4Gy). In comparison with 3DCRT, IMRT and VMAT exhibited improved target dose conformity and OAR dose sparing. A single arc can minimize the difference in the target dose due to multi-angle incidence although the delivery time is longer than 3DCRT and IMRT. Conclusion: IMRT and VMAT are better modalities for PLDR treatment of recurrent cancers with superior target dose conformity and critical structure sparing. The planning strategies/guidelines developed in this work are practical for IMRT/VMAT treatment planning to meet the dosimetry requirements of the PLDR protocol.

60 APPLIED LIFE SCIENCES↗

SU-D-18C-02: Feasibility of Using a Short ASL Scan for Calibrating Cerebral Blood Flow Obtained From DSC-MRI

Purpose: This study aimed to evaluate the feasibility of using a short arterial spin labeling (ASL) scan for calibrating the dynamic susceptibility contrast- (DSC-) MRI in a group of patients with internal carotid artery stenosis. Methods: Six patients with unilateral ICA stenosis enrolled in the study on a 3T clinical MRI scanner. The ASL-cerebral blood flow (-CBF) maps were calculated by averaging different number of dynamic points (N=1-45) acquired by using a Q2TIPS sequence. For DSC perfusion analysis, arterial input function was selected to derive the relative cerebral blood flow (rCBF) map and the delay (Tmax) map. Patient-specific CF was calculated from the mean ASL- and DSC-CBF obtained from three different masks: (1)Tmax< 3s, (2)combined gray matter mask with mask 1, (3)mask 2 with large vessels removed. One CF value was created for each number of averages by using each of the three masks for calibrating the DSC-CBF map. The CF value of the largest number of averages (NL=45) was used to determine the acceptable range(< 10%, <15%, and <20%) of CF values corresponding to the minimally acceptable number of average (NS) for each patient. Results: Comparing DSC CBF maps corrected by CF values of NL (CBFL) in ACA, MCA and PCA territories, all masks resulted in smaller CBF on the ipsilateral side than the contralateral side of the MCA territory(p<.05). The values obtained from mask 1 were significantly different than the mask 3(p<.05). Using mask 3, the medium values of Ns were 4(<10%), 2(<15%) and 2(<20%), with the worst case scenario (maximum Ns) of 25, 4, and 4, respectively. Conclusion: This study found that reliable calibration of DSC-CBF can be achieved from a short pulsed ASL scan. We suggested use a mask based on the Tmax threshold, the inclusion of gray matter only and the exclusion of large vessels for performing the calibration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-12: A New Stereological Method for Tumor Volume Evaluation for Esophageal Cancer

Purpose: Stereological method used to obtain three dimensional quantitative information from two dimensional images is a widely used tool in the study of cells and pathology. But the feasibility of the method for quantitative evaluation of volumes with 3D image data sets for radiotherapy clinical application has not been explored. On the other hand, a quick, easy-to-use and reliable method is highly desired in image-guided-radiotherapy(IGRT) for tumor volume measurement for the assessment of response to treatment. To meet this need, a stereological method for evaluating tumor volumes for esophageal cancer is presented in this abstract. Methods: The stereology method was optimized by selecting the appropriate grid point distances and sample types. 7 patients with esophageal cancer were selected retrospectively for this study, each having pre and post treatment computed tomography (CT) scans. Stereological measurements were performed for evaluating the gross tumor volume (GTV) changes after radiotherapy and the results was compared with the ones by planimetric measurements. Two independent observers evaluated the reproducibility for volume measurement using the new stereological technique. Results: The intraobserver variation in the GTV volume estimation was 3.42±1.68cm3 (the Wilcoxon matched-pairs test Resultwas Z=−1.726,P=0.084>0.05); the interobserver variation in the GTV volume estimation was 22.40±7.23 cm3 (Z=−3.296,P=0.083>0.05), which showed the consistency in GTV volume calculation with the new method for the same and different users. The agreement level between the results from the two techniques was also evaluated. Difference between the measured GTVs was 20.10±5.35 cm3 (Z=−3.101,P=0.089>0.05). Variation of the measurement results using the two techniques was low and clinically acceptable. Conclusion: The good agreement between stereological and planimetric techniques proves the reliability of the stereological tumor volume estimations. The optimized stereological technique described in this abstract may provide a quick, unbiased and reproducible tool for tumor volume estimation for treatment response assessment. Supported by NSFC (#81041107, #81171342 and #31000784)

60 APPLIED LIFE SCIENCES↗

Early Results from the Q{sub weak} Experiment

A subset of results from the recently completed Jefferson Lab Q{sub weak} experiment are reported. This experiment, sensitive to physics beyond the Standard Model, exploits the small parity-violating asymmetry in elastic {vector e}p scattering to provide the first determination of the protons weak charge Q{sub w}{sup p}. The experiment employed a 180 {micro}A longitudinally polarized 1.16 GeV electron beam on a 35 cm long liquid hydrogen target. Scattered electrons corresponding to Q{sup 2} of 0.025 GeV{sup 2} were detected in eight Cerenkov detectors arrayed symmetrically around the beam axis. The goals of the experiment were to provide a measure of Q{sub w}{sup p} to 4.2 percent (combined statistical and systematic error), which implies a measure of sin2(thetaw) at the level of 0.3 percent, and to help constrain the vector weak quark charges C{sub 1u} and C{sub 1d}. The experimental method is described, with particular focus on the challenges associated with the worlds highest power LH{sub 2} target. The new constraints on C{sub 1u} and C{sub 1d} provided by the subset of the experiments data analyzed to date will also be shown, together with the extracted weak charge of the neutron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for charmonium and charmoniumlike states in Υ ( 2 S ) radiative decays

Using a sample of 158 x 10⁶ Υ(2S) events collected with the Belle detector, charmonium and charmoniumlike states with even charge parity are searched for in Υ(2S) radiative decays. No significant Xcl or nc signal is observed, and the following upper limits at 90% confidence level (C. L.) are obtained: Β(Υ(2S)→YXco)<1.0×10 - ⁴, Β(Υ(2S)→yxc1)<3.6×10 - ⁶, Β(Υ(2S)→yxc2)<1.5 x 10 - ⁵, and Β(Υ(2S)→ync)<2.7×10 - ⁵. No significant signal of any charmoniumlike state is observed, and we obtain the limits Β(Υ(2S)→yX(3872)) x Β(X(3872)→π⁺π⁻J/ψ)<0.8×10-6, Β(Υ(2S)→γX(3872))× Β(X(3872)→ π⁺π⁻π⁰Jlψ)<2.4 x 10⁻⁶, Β(Υ(2S)→γX(3915))× Β(X(3915)→ωJ/ψ)<2.8×10⁻⁶, Β(Υ(2S)→γY(4140)) x Β(Y(4140)→$\phi$J/ψ))<1.2 x 10 - ⁶, and Β(Υ(2S)→yX(4350))× Β(X(4350)→$\phi$J/ψ))<1.3×10⁻⁶ at 90% C. L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical simulation of multi-layered textile composite reinforcement forming

One important perspective in aeronautics is to produce large, thick or/and complex structural composite parts. The forming stage presents an important role during the whole manufacturing process, especially for LCM processes (Liquid Composites Moulding) or CFRTP (Continuous Fibre Reinforcements and Thermoplastic resin). Numerical simulations corresponding to multi-layered composite forming allow the prediction for a successful process to produce the thick parts, and importantly, the positions of the fibres after forming to be known. This paper details a set of simulation examples carried out by using a semi-discrete shell finite element made up of unit woven cells. The internal virtual work is applied on all woven cells of the element taking into account tensions, in-plane shear and bending effects. As one key problem, the contact behaviours of tool/ply and ply/ply are described in the numerical model. The simulation results not only improve our understanding of the multi-layered composite forming process but also point out the importance of the fibre orientation and inter-ply friction during formability.

36 MATERIALS SCIENCE↗

Simulation of Forming and Wrinkling of Textile Composite Reinforcements

Because of the very weak textile bending stiffness, wrinkles are frequent during composite reinforcement forming. The simulation of the shape of these wrinkles during the forming process permits to verify there is no wrinkle in the useful part of the preform. In this paper the role of tensions, in-plane shear and bending rigidities in wrinkling development are analyzed. In-plane shear plays a main role for onset of wrinkles in double-curved shape forming but wrinkling is a global phenomenon depending on all strains and stiffnesses and on boundary conditions. The bending stiffness mainly determines the shape of the wrinkles and a membrane approach it is not sufficient to simulate wrinkles.

36 MATERIALS SCIENCE↗

A Mechanistic Study on the Formation of Silver Nanoplates in the Presence of Silver Seeds and Citric Acid or Citrate Ions

The world on a plate: In addition to their role as a capping agent that selectively binds to the {l_brace}111{r_brace} faces of silver, the carboxylate group can coordinate with Ag+ ions to form complexes and thus substantially reduce the reduction rate of Ag+ ions, leading to the formation of silver seeds with both twin planes and stacking faults.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Leptonic partial widths of the excited {psi} states

The resonance parameters of the excited {psi}-family resonances, namely, the {psi}(4040), {psi}(4160), and {psi}(4415), were determined by fitting the R values measured by experiments. It is found that the previously reported leptonic partial widths of these states were merely one possible solution among a four-fold ambiguity. By fitting the most precise experimental data on the R values measured by the BES collaboration, this work presents all four sets of solutions. These results may affect the interpretation of the charmonium and charmonium-like states above 4 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for charmonium and charmoniumlike states in {Upsilon}(1S) radiative decays

Using a sample of 102x10{sup 6} {Upsilon}(1S) events collected with the Belle detector, we report on the first search for charge-parity-even charmonium and charmoniumlike states in {Upsilon}(1S) radiative decays. No significant {chi}{sub cJ} or {eta}{sub c} signal is observed and 90% C.L. limits on B({Upsilon}(1S){yields}{gamma}{chi}{sub c0})<6.5x10{sup -4}, B({Upsilon}(1S){yields}{gamma}{chi}{sub c1})<2.3x10{sup -5}, B({Upsilon}(1S){yields}{gamma}{chi}{sub c2})<7.6x10{sup -6}, and B({Upsilon}(1S){yields}{gamma}{eta}{sub c})<5.7x10{sup -5} are obtained. The product branching fraction limits B({Upsilon}(1S){yields}{gamma}X(3872))B(X(3872){yields}{pi}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -}J/{psi})<1.6x10{sup -6}, B({Upsilon}(1S){yields}{gamma}X(3872))B(X(3872){yields}{pi}{sup +}{pi}{sup -}{pi}{sup 0}J/{psi})<2.8x10{sup -6}, B({Upsilon}(1S){yields}{gamma}X(3915)) B(X(3915){yields}{omega}J/{psi})<3.0x10{sup -6}, and B({Upsilon}(1S){yields}{gamma}Y(4140))B(Y(4140){yields}{phi}J/{psi})<2.2x10{sup -6} are obtained at the 90% C.L. Furthermore, no evidence is found for excited charmonium states below 4.8 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First moments of nucleon generalized parton distributions

We extrapolate the first moments of the generalized parton distributions using heavy baryon chiral perturbation theory. The calculation is based on the one loop level with the finite range regularization. The description of the lattice data is satisfactory, and the extrapolated moments at physical pion mass are consistent with the results obtained with dimensional regularization, although the extrapolation in the momentum transfer to t=0 does show sensitivity to form factor effects, which lie outside the realm of chiral perturbation theory. We discuss the significance of the results in the light of modern experiments as well as QCD inspired models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗