Digitalizing Building Control Deployment for Retrofits: A Case Study on Demand-Flexible Control Sequences
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Wetter, Michael.
Explore the source record for details and available documents.
Not Available
The CDL-PLC translator aims at translating control sequences for building energy systems from the CDL CXF format to the PLCopen XML format. The CDL CXF developed at LBL within the OpenBuildingControl project, and now being standardized via ASHRAE Standard 231P, enables expressing control sequences developed in the simulation environment Modelica in a JSON format. The PLCopen XML is an existing exchange format standardized in IEC 61131-10 for Programmable Logic Controllers (PLCs) following the IEC 61131 standard as one target system of CDL among others. The translation from the CDL CXF to the PLCopen XML contributes to a seamless workflow from the model-based development of control sequences in simulation environments, which is not building practice today, and their digital implementation on building controllers, which replaces graphical and textual documents used for this purpose today. The translator is at a prototypical stage and enables, as a proof of concept, the translation of very simple control sequences composed of 4 selected function blocks out of 137 function blocks defined in CDL. The translation includes the connection of inputs and outputs of function blocks and the expression of a control function in CDL to the equivalent code in IEC 61131-3.
Domain-overarching system models are crucial to investigate sector coupling concepts. Specifically, the coupling of building and electrical energy systems becomes crucial to integrate renewable energy sources such as photovoltaic power systems (PV). For such interdisciplinary simulation models, Modelica is a suitable language. However, most open-source Modelica libraries are either domain-specific or lack simple-to-parameterize PV models. We close this gap by developing a PV model for the IBPSA Modelica library. The model comprises two I-V-characteristic models and three mounting-dependent approaches to calculate the cell temperature. The I-V-characteristic models follow a single- and two-diodes approach. This study uses measurement data from a rooftop PV system in Berlin, Germany, for validation. The focus lies on comparing the implemented single- and two-diodes approach. Results prove that both models accurately calculate the modules’ DC power output and cell temperature. The two-diodes approach slightly outperforms the single-diode one at the expense of a higher parameterization effort.
This article reports on our experience in creating Modelica models for systems with thousands of configurations and closed-loop controls. The development of such templates required exploration of class parameterization techniques and data structures for handling large sets of equipment parameters. By describing these issues and the approach taken, we show how the Modelica language can support advanced templating logic. The main limitation we encountered relates to parameter assignment and propagation. The interpretation of parameter attributes at user interface runtime, or the handling of non-trivial constructs involving record classes at compile time is not consistently supported by Modelica tools. This leads to choices that are difficult to make when looking for a generic implementation.
This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.
Not Available
Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.
Not Available
This paper presents a low-order aquifer thermal energy storage (ATES) model for simulation of combined subsurface and above-surface energy systems. The model is included in the Modelica IBPSA Library, which is a free open-source library with basic models for building and district energy and control systems. The model uses a lumped-component method, in which the transient conductive-convective heat and mass transfer equation is radially discretized. To verify the accuracy of the model, we present an inter-model comparison from a simulation test suite. Results show that the Modelica ATES model is in good agreement, with a normalized mean bias error for yearly variation of aquifer temperatures of 1.6×10−2 and 9×10−5 at 1 m and 10 m distance from the well.
5th generation district heating and cooling system (5GDHC) are a relatively new concept. They use a single district loop near ambient temperature to provide heating and cooling. This paper improves on the modelling and control of a 5GDHC system called the reservoir network. The study updates the sewage heat exchanger plant model to more realistically represent seasonal changes, uses refined pump models with variable efficiency, introduces a ground coupled district pipe model to consider the inertia of the district network and implements a new control strategy for geothermal storage and sewage heat exchanger. The new approach reduced operating costs, mainly due to pumping cost for storage, sewage heat exchanger plant and distribution pump, while increasing the overall robustness of the approach in different sizing conditions. Thanks to the new controller, the pumping consumption was reduced by 21% with respect to the original baseline. Furthermore, the new control makes the system take better advantage of design changes, when reducing borehole field size and increasing the sewage heat exchanger size, the pumping energy savings become 29% with respect to the original baseline. Lastly, borehole field temperature stability was analyzed through 40 years of simulation.
This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.
Over the past decade, fundamental changes in artificial intelligence (AI)—from foundational to applied—have delivered dramatic insights across a wide breadth of U.S. Department of Energy (DOE) mission space. AI is helping to augment and improve scientific and engineering workflows (e.g., for control, design, and dramatic performance gains through surrogate models) in national security, the Office of Science, and DOE’s applied energy programs. The progress and potential for AI in DOE science was captured in the 2020 “AI for Science” report from the DOE laboratory community in collaboration with academia and industry. Specific scientific areas ready to further leverage the power of AI ranged from the scale and performance of computational models to data analysis to creating new classes of observations using computer vision. Since that report, the scale and scope of scientific AI have accelerated, revealing new, emergent properties that yield insights that go beyond enabling opportunities to being potentially transformative in the way that scientific problems are posed and solved. Thus, under the guidance of both the Office of Science (SC) and the National Nuclear Security Administration (NNSA), the DOE national laboratories organized a series of workshops in 2022 to gather input on new and rapidly emerging opportunities and challenges of scientific AI. This 2023 report is a synthesis of those workshops. The scientific community believes AI can have a foundational impact on a broad range of DOE missions, including science, energy, and national security. Further, DOE has unique capabilities that enable the community to drive progress in scientific use of AI, building on long-standing DOE strengths and investments in computation, data, and communications infrastructure, spanning the Energy Sciences Network (ESnet), the Exascale Computing Project (ECP), and integrative programs such as the NNSA Office of Defense Programs Advanced Simulation and Computing (ASC) and the SC Scientific Discovery through Advanced Computing (SciDAC) programs.
This paper investigates the energy performance and sizing criteria of 5th generation district heating and cooling (5GDHC) networks as a function of the heat distribution temperature in the building systems connected to the district network. An energy simulation model of a 5GDHC network was developed in Modelica for a case study located in Denmark. Calculations were carried out for four different building heating systems. Simulation results show that reducing the heat distribution temperatures from 70 °C to 23 °C leads to around 40% annual electric energy savings (from 10.4 kWh/m 2 to 6.2 kWh/m 2 ) for the operation of the heat pumps. Heat distribution temperatures of 23 °C cause higher water mass flow rates through the network, leading to annual electric energy consumption for the circulation pumps that are almost doubled (from 0.16 kWh/m 2 to 0.3 kWh/m 2 ) compared to the reference case at 70 °C. Furthermore, the paper discusses how the results obtained from the Danish case study can be generalized and applied to other cases using a simplified mathematical approach. In conclusion, it is found that about 1.5% of electric energy savings can be achieved for each temperature degree reduction in the heat distribution system.
ctrl-flow is a software that assists users in selecting a building control sequence from a library of control sequences that are implemented in the Modelica Buildings Library. The software allows selecting, configuring and editing the control sequences. It also allows exporting the sequence for use in building project design documents in Modelica-based simulations. The export will be in a json intermediate format, in the Modelica Language, in the Control Description Language and in English language format, such as in a Word document. The software functions as a web based application that includes a graphical user interface.
Simulation programs often assume constant hydraulic efficiency for fan or pump models when performance curves are unavailable. This is inaccurate because the hydraulic efficiency varies with the operation condition. It therefore consistently underestimates the power draw at off-design conditions at which the hydraulic efficiency drops. Use of a modified Euler number allows computing the hydraulic efficiency and shaft power with limited data. Others showed the validity of the modified Euler number for fan efficiency calculations. We show that it is also applicable for pumps, and present its implementation in Modelica for a fan or pump model. Here, the only input required from the user is one data point at which the hydraulic efficiency is at its maximum. The reported method is applicable regardless of the type, size, or operational region of the fan or pump. Across a sample of eighteen sets of pump data and seven sets of fan data, the errors of the computed power from interpolated data were within 15% for the range of 20% - 70% of maximum flow rate and 40% - 90% of maximum pressure rise, excluding outliers.
Nearly all large commercial buildings have heating, ventilation and air conditioning (HVAC) systems, lighting systems, safety and other systems controlled by a computer—a dedicated server with a building energy management system (BMS). However, these BMSs are proprietary with each building’s assets (that is, fans, valves, pumps, and their setpoints) named and coded uniquely by the BMS vendor or engineer; building analytics and control algorithms are written specific to the assets and the building. Thus, any control updates or analytics to improve building performance—especially critical to reduce greenhouse emissions or improve load flexibility—are labor intensive and costly. The Brick schema was developed so the same analysis or control algorithms can work on a variety of buildings if each is digitally represented in a Brick data model. The goal of this project was to further the development of Brick to extend it beyond an academic project with demonstrated success in a small field study, to a practical choice for industrial and commercial stakeholders seeking to realize value from building data. To do this, we executed four objectives: (1) expand the Brick schema including its modeling capabilities and vocabulary, (2) develop tools for integrating Brick with existing digital technologies and representations in buildings, (3) develop an open-source analytics platform to facilitate use of Brick in delivering data value, and (4) demonstrate Brick-driven analytics and controls in real settings.
Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.