Search NASA⌕ Search

Engineering topics

Williams, Ashley N.

Publications and source records attributed to Williams, Ashley N..

Excitation Wavelength-Dependent Emission from Americium(III) in Mineral Acid Solutions

The photoluminescence behavior of trivalent americium, Am(III), in mineral acid solutions is reported under direct-metal excitation at seven high-energy wavelengths in the ultraviolet and visible regions (378-512 nm). This study revealed a dependence of the Am(III)-based visible emission profile on the chosen excitation wavelength. For example, excitation at the more common wavelength of 504 nm produces the two expected emission bands: one at approximately 600 nm (5D1' to 7F0') and another at 690 nm (5D1' to 7F1'). When the excitation wavelength is shifted to 398 nm (targeting the 5D3', 5H7' from 7F0' transitions), the emission occurs almost exclusively at 600 nm. This behavior is unexpected and potentially highlights fundamental knowledge gaps in the current understanding of the intraconfigurational 5f-5f electronic transitions that give rise to Am(III) photoluminescence. Although a full interpretation of these results is limited by the incomplete understanding of Am(III) speciation in mineral acid systems, this study explores several potential explanations for the observed behavior and challenges the widely held assumption of a single emissive Am(III) species.

Americium↗

The evaluation of aluminum and iron metal oxide settling behaviors for Hanford insoluble solids waste preprocessing

The Hanford site is currently one of the largest and most expensive cleanup sites for hazardous, radioactive waste. Over 20% of the waste found at the Hanford site is in the form of a high activity sludge. The insoluble solids in the sludge will need to be concentrated prior to vitrification in the high-level waste (HLW) melter. This will minimize the amount of liquid that will be evaporated during the melting process and expedite the melter processing rate. One proposed option for concentrating the insoluble solids is gravity settling in the storage tanks. Metal oxide compounds containing aluminum and iron make up the majority of the insoluble solids in the sludge, therefore understanding the behavior of these compounds in various tank waste matrices can facilitate sludge pretreatment options. A study of non-radioactive slurry solutions containing Al(OH) 3 (gibbsite), AlO(OH) (boehmite), and Fe 2 O 3 (iron (III) oxide) was conducted to determine the time dependent interface behavior and settling rates of these compounds. Variations in solids loading and sodium concentration were evaluated to represent waste processing conditions and the results of these settling studies were compared with prior tank waste settling tests. Information gathered from these studies can be used to inform future decisions on sludge treatment processes of the insoluble solids processed at the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Na Concentration on Cs Distribution with Crystalline Silicotitanate in Tank Waste Simulants

Crystalline silicotitanate (CST) ion exchange media is currently utilized in the tank side cesium removal (TSCR) system on the Hanford site to remove Cs-137 from the tank waste supernate. As the main dose contributor to the liquid supernate in Hanford tank waste, it is necessary to remove the Cs-137 to expedite low activity waste processing and immobilization. Ongoing batch contact experiments with CST have been done to tease out the impact of group II metals, anions, potassium, and temperature on Cs removal to better understand bounding conditions for operations as well as aid in development of a wholesome isotherm model to predict Cs behavior in the tank waste. This paper discusses the impact of Na concentration on Cs exchange and provides insight into the challenges associated with activity coefficient estimations for modeling Cs distribution in tank waste matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sludge Processing Options for early HLW Treatment at Hanford

The U.S. Department of Energy’s (DOE) Hanford Site has 177 underground storage tanks that contain wastes from past nuclear fuel reprocessing and waste-management operations. Over 20% of this waste is in the form of an insoluble sludge that will require solids concentration and washing prior to vitrification for long-term disposal. An assessment of potential flowsheet operations to support feed preparation activities prior to high level waste (HLW) vitrification has been conducted to better evaluate pretreatment processing options. Settling studies assessing the baseline approach of a settle-decant method were explored as well as a crossflow filtration system to be used alternatively for concentrating and washing HLW sludge. Significant variations in behavior of settling rates and sludge characteristics give reason to evaluate alternative pretreatment options for the HLW. Non-radioactive sludge containing iron oxide, boehmite, and gibbsite were evaluated via gravity settling and crossflow filtration to determine the behavior of these compounds in various tank waste matrices. Understanding the predictive capabilities of HLW solids settling as well as sludge concentration via crossflow filtration can help provide technical guidance during flowsheet planning.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗