Search NASA⌕ Search

Engineering topics

Wu, A.

Publications and source records attributed to Wu, A..

28 records · Page 2

Development of a CW NCRF Photoinjector using Solid Freeform Fabrication (SFF)

A key issue for high av­er­age power, nor­mal con­duct­ing radio fre­quen­cy (NCRF), pho­toin­jec­tors is ef­fi­cient struc­ture cool­ing. To that end, Ra­di­a­Beam has been de­vel­op­ing the use of Solid Freeform Fab­ri­ca­tion (SFF) for the pro­duc­tion of NCRF pho­toin­jec­tors. In this paper we de­scribe the pre­lim­i­nary de­sign of a high gra­di­ent, very high duty cycle, pho­toin­jec­tor com­bin­ing the cool­ing ef­fi­cien­cy only pos­si­ble through the use of SFF, and the RF ef­fi­cien­cy of a re-en­trant gun de­sign. Sim­u­la­tions of the RF and ther­mal-stress per­for­mance will be pre­sent­ed, as well as ma­te­ri­al test­ing of SFF com­po­nents.

Frigola, P.↗

Recent Progress on Cross-Comparison of Terra and Aqua MODIS Calibration Using Dome C

For the past few years, the MODIS Characterization Support Team (MCST) at NASA/GSFC has continued to evaluate the Terra and Aqua MODIS calibration long-term stability and their calibration consistency using sensor observations over the Dome Concordia, Antarctica. Early results from Dome C observations show that the calibration of bands I and 2 (0.65 and 0.86 micron) is consistent within 1-2% and bands 31 and 32 (11 and 12 micron) differences are less than a couple of tenths of Kelvin, demonstrating that this site can provide a useful calibration reference for a wide range of Earth-observing sensors from visible (VIS) to long-wave infrared (LWIR). Recently, the Dome C area has been endorsed by the CEOS as a reference standard site for sensor cross-comparison. This, as a result, has led to an invitation to the broad community to participate in a CEOS comparison of top-of-atmosphere (TOA) spectral radiance/reflectance over Dome C. In this paper, we provide a brief description of the methodologies and report our recent progress on cross-comparison of Terra and Aqua MODIS spectral bands using observations over this area, including data provided in support of the upcoming CEOS comparison. Emphasis of this paper is on the long-term data records of MODIS instruments, their calibration consistency, and challenging issues.

Xiong, X.↗

MODIS On-board Blackbody Performance

Currently, there are two MODIS instruments operated on-orbit: one on-board the Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. MODIS is a scanning radiometer that has 16 thermal emissive bands (TEBs) in the MWIR and LWIR regions. The remaining spectral bands are in the VISINIR and SWIR regions. The TEBs have a total of 160 detectors (10 detectors per band), which are calibrated on-orbit using an on-board blackbody (BB). MODIS TEB calibration is performed via a quadratic algorithm with its linear calibration coefficients updated on a scan-by-scan basis using each detector's response to the BB. The offset and nonlinear terms of the quadratic calibration equation are stored in a look-up table (LUT). The LUT parameters are derived from pre-launch calibration and updated on-orbit from BB observations, as needed. Typically, the BB is set at a fixed temperature. Periodically, a warm-up and cool-down activity is performed, which enables the BB temperature to be varied from instrument ambient up to 315K. The temperature of the BB is measured each scan using 12 thermistors, which were fully characterized pre-launch with reference to the NIST temperature scale. This paper describes MODIS on-board BB operational activities and performance. The TEB detector response (short-term stability and long-term changes) and noise characterization results derived from BB observations and their impact on the TEB calibration uncertainty are also presented.

Xiong, Xiaoxiong↗

Assessment of MODIS Scan Mirror Reflectance Changes On-Orbit

Since launch, the NASA EOS Terra and Aqua MODIS have operated successfully for more than 8 and 6 years, respectively. MODIS collects data using a two-sided scan mirror over a large scan angular range. The scan mirror is made of a polished, nickel-plated beryllium base coated with high purity silver, which is then over-coated with the Denton proprietary silicon monoxide and silicon dioxide mixture. The scan mirror's reflectance was characterized pre-launch using its witness samples, and the response versus scan angle was measured at the sensor system level. In this study, we present an assessment of MODIS scan mirror on-orbit degradation by examining changes of spectral band response over each sensor's mission lifetime. Results show that the scan mirror's optical properties for both Terra and Aqua MODIS have experienced significant degradation since launch in the VIS spectral region, which is mirror side dependent as well as scan angle dependent. In general, the mirror degradation is more severe for Terra MODIS than Aqua MODIS, especially during recent years. For Terra MODIS, the degradation rate is noticeably different between the mirror sides. On the other hand, there has been little mirror side dependent difference for Aqua MODIS.

Xiong, Xiaoxiong↗

Detector Noise Characterization and Performance of MODIS Thermal Emissive Bands

MODIS has 16 thermal emissive bands, a total of 160 individual detectors (10 for each spectral bands), located on the two cold focal plane assemblies (CFPA). MODIS TEB detectors were fully characterized pre-launch in a thermal vacuum (TV) environment using a NIST traceable blackbody calibration source (BCS) with temperatures ranging from 170 to 340K. On-orbit the TEB detectors are calibrated using an on-board blackbody (BB) on a scan-by-scan basis. For nominal on-orbit operation, the on-board BB temperature is typically controlled at 285K for Aqua MODIS and 290K for Terra MODIS. For the MODIS TEB calibration, each detector's noise equivalent temperature difference (NEdT) is often used to assess its performance and this parameter is a major contributor to the calibration uncertainty. Because of its impact on sensor calibration and data product quality, each MODIS TEB detector's NEdT is monitored on a daily basis at a fixed BB temperature and completely characterized on a regular basis at a number of BB temperatures. In this paper, we describe MODIS on-orbit TEB NEdT characterization activities, approaches, and results. We compare both pre-launch and on-orbit performance with sensor design specification and examine detector noise characterization impact on the calibration uncertainty. To date, 135 TEB detectors (out of a total of 160 detectors) in Terra MODIS (launched in December 1999) and 158 in Aqua MODIS (launched in May 2002) continue to perform with their NEdT below (or better than) their design specifications. A complete summary of all TEB noisy detectors, identified both pre-launch and on-orbit, is provided.

Xiong, X.↗

An Overview of Inter-comparison Methodologies for Terra and Aqua MODIS Calibration

With increasing efforts on data fusion and long-term climate data records (CDR) using observations made by multiple sensors, on the same or different platforms, their cross-calibration and validation work has become more and more important. The uncertainties of the climate models and data records depend not only on the calibration quality of individual sensors but also on their calibration consistency. This paper provides an overview of methodologies used by the MODIS Characterization Support Team (MCST) at NASA GSFC for the inter-comparison studies of Terra and Aqua MODIS on-orbit calibration. Each MODIS was built with a set of onboard calibrators (OBC) that include a blackbody (BB), a solar diffuser (SD), and a solar diffuser stability monitor (SDSM). The BB is primarily used for the thermal emissive bands (TEB) calibration and the SD/SDSM system for the reflective solar bands (RSB) calibration. Although the-instrument design and calibration approach are nearly identical for both Terra and Aqua MODIS and they all went through an extensive and similar pre-launch calibration and characterization process, still their on-orbit calibration consistency needs to be carefully examined and validated as many science products have been generated from observations made by both instruments. Methodologies discussed in this paper include inter-comparison studies using the Moon, a third sensor, and ground targets. Our results show that Terra and Aqua reflective solar bands and thermal emissive bands have been calibrated consistently with excellent long-term stabilities. For the 11 and 12 micrometers sea surface temperature (SST) bands, the calibration difference of Terra and Aqua MODIS is less than 0.2K.

Xiong, X.↗

Inter-Comparison of Terra and Aqua MODIS

Nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have been operating on-board the NASA's Earth Observing System (EOS) Terra and Aqua satellites since their launches in December 1999 and May 2002, respectively. Each MODIS has 20 reflective solar bands (RSB) with center wavelengths ranging from 0.41 to 2.1 micrometers and 16 thermal emissive bands (TEB) from 3.7 to 14.4 micrometers. The absolute radiometric accuracy requirements (1 sigma) at the typical spectral radiance levels are plus or minus 2% for the RSB for the RSB reflectance factors and plus or minus 5% for the RSB radiance products. With few exceptions, the TEB requirements are plus or minus 1%. The sensor's on-orbit radiometric calibration is performed by the on-board calibrators, including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system for the RSB and a V-groove flat panel blackbody (BB) for the TEB. In addition, the Moon has been extensively used by both Terra and Aqua MODIS to support their on-orbit calibration and characterization. This paper presents MODIS lunar calibration methodology and inter-comparison of Terra and Aqua MODIS in the VIS/NIR spectral regions. Current results from lunar observations show that the calibration difference between the two sensors is less than plus or minus 1%. Also discussed in this paper are the approaches and results of inter-comparison of Terra and Aqua MODIS in the TEB using closely matched thermal infrared (TIR) channels on the Advanced Very High Resolution Radiometer (AVHRR) at 11 and 12 micrometers.

Xiong, X.↗

On-orbit Characterization of RVS for MODIS Thermal Emissive Bands

Response versus scan angle (RVS) is a key calibration parameter for remote sensing radiometers that make observations using a scanning optical system, such as a scan mirror in MODIS and GLI or a rotating telescope in SeaWiFS and VIIRS, since the calibration is typically performed at a fixed viewing angle while the Earth scene observations are made over a range of viewing angles. Terra MODIS has been in operation for more than four years since its launch in December 1999. It has 36 spectral bands covering spectral range from visible (VIS) to long-wave infrared (LWIR). It is a cross-track scanning radiometer using a two-sided paddle wheel scan mirror, making observations over a wide field of view (FOV) of +/-55 deg from the instrument nadir. This paper describes on-orbit characterization of MODIS RVS for its thermal emissive bands (TEB), using the Earth view data collected during Terra spacecraft deep space maneuvers (DSM). Comparisons with pre-launch analysis and early on-orbit measurements are also provided.

Xiong, X.↗

Measurement selection for parametric IC fault diagnosis

Experimental results obtained with the use of measurement reduction for statistical IC fault diagnosis are described. The reduction method used involves data pre-processing in a fashion consistent with a specific definition of parametric faults. The effects of this preprocessing are examined.

Wu, A.↗

Neural net diagnostics for VLSI test

This paper discusses the application of neural network pattern analysis algorithms to the IC fault diagnosis problem. A fault diagnostic is a decision rule combining what is known about an ideal circuit test response with information about how it is distorted by fabrication variations and measurement noise. The rule is used to detect fault existence in fabricated circuits using real test equipment. Traditional statistical techniques may be used to achieve this goal, but they can employ unrealistic a priori assumptions about measurement data. Our approach to this problem employs an adaptive pattern analysis technique based on feedforward neural networks. During training, a feedforward network automatically captures unknown sample distributions. This is important because distributions arising from the nonlinear effects of process variation can be more complex than is typically assumed. A feedforward network is also able to extract measurement features which contribute significantly to making a correct decision. Traditional feature extraction techniques employ matrix manipulations which can be particularly costly for large measurement vectors. In this paper we discuss a software system which we are developing that uses this approach. We also provide a simple example illustrating the use of the technique for fault detection in an operational amplifier.

Lin, T.↗