Search NASA⌕ Search

Engineering topics

Xu, Yan

Publications and source records attributed to Xu, Yan.

At least 127 records · Page 7

Pb exposure attenuates hypersensitivity in vivo by increasing regulatory T cells

Pb is a common environmental pollutant affecting various organs. Exposure of the immune system to Pb leads to immunosuppression or immunodysregulation. Although previous studies showed that Pb exposure can modulate the function of helper T cells, Pb immunotoxicity remains incompletely understood. In this study, we investigated the effect of Pb exposure on T cell development, and the underlying mechanism of Pb-induced suppression of the delayed-type hypersensitivity (DTH) response in vivo. Sprague–Dawley rats were exposed to 300 ppm Pb-acetate solution via the drinking water for six weeks, and we found that Pb exposure significantly increased Pb concentrations in the blood by 4.2-fold (p < 0.05) as compared to those in the control rats. In Pb-exposed rats, the amount of thymic CD4{sup +}CD8{sup −} and peripheral CD4{sup +} T cells was significantly reduced, whereas, CD8{sup +} population was not affected. In contrast to conventional CD4{sup +} T cells, Foxp3{sup +} regulatory T cells (Tregs) were increased in both the thymus and peripheral lymphoid organs of Pb-exposed rats. In line with the increase of Tregs, the DTH response of Pb-exposed rats was markedly suppressed. Depletion of Tregs reversed the suppression of DTH response by Pb-exposed CD4{sup +} T cells in an adoptive transfer model, suggesting a critical role of the increased Tregs in suppressing the DTH response. Collectively, this study revealed that Pb-exposure may upregulate Tregs, thereby leading to immunosuppression. -- Highlights: ► Pb exposure impaired CD4{sup +} thymic T cell development. ► Peripheral T lymphocytes were reduced following Pb exposure. ► Pb exposure increases thymic and peripheral Treg cells in rats. ► Tregs played a critical role in Pb-exposure-induced immune suppression.

60 APPLIED LIFE SCIENCES↗

EVOLUTION OF RELATIVE MAGNETIC HELICITY AND CURRENT HELICITY IN NOAA ACTIVE REGION 11158

Both magnetic and current helicities are crucial ingredients for describing the complexity of active-region magnetic structure. In this Letter, we present the temporal evolution of these helicities contained in NOAA active region 11158 during five days from 2011 February 12 to 16. The photospheric vector magnetograms of the Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory were used as the boundary conditions for the coronal field extrapolation under the assumption of nonlinear force-free field, from which we calculated both relative magnetic helicity and current helicity. We construct a time-altitude diagram in which altitude distribution of the magnitude of current helicity density is displayed as a function of time. This diagram clearly shows a pattern of upwardly propagating current helicity density over two days prior to the X2.2 flare on February 15 with an average propagation speed of {approx}36 m s{sup -1}. The propagation is synchronous with the emergence of magnetic flux into the photosphere, and indicative of a gradual energy buildup for the X2.2 flare. The time profile of the relative magnetic helicity shows a monotonically increasing trend most of the time, but a pattern of increasing and decreasing magnetic helicity above the monotonic variation appears prior to each of two major flares, M6.6 and X2.2, respectively. The physics underlying this bump pattern is not fully understood. However, the fact that this pattern is apparent in the magnetic helicity evolution but not in the magnetic flux evolution makes it a useful indicator in forecasting major flares.

79 ASTRONOMY AND ASTROPHYSICS↗

CHARACTERISTIC SIZE OF FLARE KERNELS IN THE VISIBLE AND NEAR-INFRARED CONTINUA

In this Letter, we present a new approach to estimate the formation height of visible and near-infrared emission of an X10 flare. The sizes of flare emission cores in three wavelengths are accurately measured during the peak of the flare. The source size is the largest in the G band at 4308 A and shrinks toward longer wavelengths, namely the green continuum at 5200 A and NIR at 15600 A, where the emission is believed to originate from the deeper atmosphere. This size-wavelength variation is likely explained by the direct heating model as electrons need to move along converging field lines from the corona to the photosphere. Therefore, one can observe the smallest source, which in our case is 0.''65 {+-} 0.''02 in the bottom layer (represented by NIR), and observe relatively larger kernels in upper layers of 1.''03 {+-} 0.''14 and 1.''96 {+-} 0.''27, using the green continuum and G band, respectively. We then compare the source sizes with a simple magnetic geometry to derive the formation height of the white-light sources and magnetic pressure in different layers inside the flare loop.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure of the pentameric ligand-gated ion channel ELIC cocrystallized with its competitive antagonist acetylcholine

ELIC, the pentameric ligand-gated ion channel from Erwinia chrysanthemi, is a prototype for Cys-loop receptors. Here we show that acetylcholine is a competitive antagonist for ELIC. We determine the acetylcholine–ELIC cocrystal structure to a 2.9-Å resolution and find that acetylcholine binding to an aromatic cage at the subunit interface induces a significant contraction of loop C and other structural rearrangements in the extracellular domain. The side chain of the pore-lining residue F247 reorients and the pore size consequently enlarges, but the channel remains closed. We attribute the inability of acetylcholine to activate ELIC primarily to weak cation-π and electrostatic interactions in the pocket, because an acetylcholine derivative with a simple quaternary-to-tertiary ammonium substitution activates the channel. This study presents a compelling case for understanding the structural underpinning of the functional relationship between agonism and competitive antagonism in the Cys-loop receptors, providing a new framework for developing novel therapeutic drugs.

59 BASIC BIOLOGICAL SCIENCES↗

Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction

With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.

Gopi Reddy, Lakshmi Reddy↗

Real Power and Reactive Power Control of a Three-Phase Single-Stage-PV System and PV voltage Stability

Grid-connected photovoltaic (PV) systems with power electronic interfaces can provide both real and reactive power to meet power system needs with appropriate control algorithms. This paper presents the control algorithm design for a three-phase single-stage grid-connected PV inverter to achieve either maximum power point tracking (MPPT) or a certain amount of real power injection, as well as the voltage/var control. The switching between MPPT control mode and a certain amount of real power control mode is automatic and seamless. Without the DC-to-DC booster stage, PV DC voltage stability is an important issue in the control design especially when the PV inverter is operating at maximum power point (MPP) with voltage/var control. The PV DC voltage collapse phenomenon and its reason are discussed. The method based on dynamic correction of the PV inverter output is proposed to ensure PV DC voltage stability. Simulation results of the single-stage PV system during system disturbances and fast solar irradiation changes confirm that the proposed control algorithm for single-stage PV inverters can provide appropriate real and reactive power services and ensure PV DC voltage stability during dynamic system operation and atmospheric conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous and Adaptive Voltage Control using Multiple Distributed Energy Resources

Voltage regulation using distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control has drawn increasing interests. This paper addresses the challenges of controlling multiple DEs to regulate voltages in distribution systems using an autonomous and adaptive control approach. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters with multiple DEs. Hence, the proposed control method is theoretically solid. Simulation results confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation or inefficiency. This method is autonomous based on local information and the other DEs input without the instructions from any control center, is widely adaptive to variable power system operational situations, and has a high tolerance to data shortage of systems parameter. Hence, it is suitable for broad utility application

Li, Huijuan↗

A Review of Barriers to and Opportunities for the Integration of Renewable Energy in the Southeast

The objectives of this study were to prepare a summary report that examines the opportunities for and obstacles to the integration of renewable energy resources in the Southeast between now and the year 2030. The report, which is based on a review of existing literature regarding renewable resources in the Southeast, includes the following renewable energy resources: wind, solar, hydro, geothermal, biomass, and tidal. The evaluation was conducted by the Oak Ridge National Laboratory for the Energy Foundation and is a subjective review with limited detailed analysis. However, the report offers a best estimate of the magnitude, time frame, and cost of deployment of renewable resources in the Southeast based upon the literature reviewed and reasonable engineering and economic estimates. For the purposes of this report, the Southeast is defined as the states of Alabama, Arkansas, Florida, Georgia, Kentucky, Louisiana, Mississippi, North Carolina, South Carolina, Tennessee, Virginia, and West Virginia. In addition, some aspects of the report (wind and geothermal) also consider the extended Southeast, which includes Maryland, Missouri, Oklahoma, and Texas. A description of the existing base of renewable electricity installations in the region is given for each technology considered. Where available, the possible barriers and other considerations regarding renewable energy resources are listed in terms of availability, investment and maintenance costs, reliability, installation requirements, policies, and energy market. As stated above, the report is a comprehensive review of renewable energy resources in the southeastern region of United States based on a literature study that included information obtained from the Southern Bio-Power wiki, sources from the Energy Foundation, sources available to ORNL, and sources found during the review. The report consists of an executive summary, this introductory chapter describing report objectives, a chapter on analysis methods and the status of renewable resources, chapters devoted to each identified renewable resource, and a brief summary chapter. Chapter 2 on analysis methods and status summarizes the benefits of integrating renewable energy resources in the Southeast. The utilization of the existing fuels, both the fossil fuels and the renewable energy resources, is evaluated. The financial rewards of renewable resources are listed, which includes the amount of fuel imported from outside the Southeast to find the net benefit of local renewable generation, and both the typical and new green job opportunities that arise from renewable generation in the Southeast. With the load growth in the Southeast, the growth of transmission and fossil fuel generation may not meet the growing demands for energy. The load growth is estimated, and the benefits of renewable resources for solving local growing energy demands are evaluated. Chapters 3-7 discuss the key renewable energy resources in the Southeast. Six resources available in this region that are discussed are (1) wind, including both onshore and offshore; (2) solar, including passive, photovoltaic, and concentrating; (3) biomass energy, including switchgrass, biomass co-firing, wood, woody biomass, wood industry by-products (harvesting residues, mill waste, etc.), agricultural byproducts, landfill gas to energy and anaerobic digester gas; (4) hydro; and (5) geothermal. Because of limited development, ocean wave and tidal were not considered to be available in significant quantity before 2030 and are not presented in the final analysis. Estimates on the location of potential megawatt generation from these renewable resources in the Southeast are made. Each chapter will describe the existing base of the renewable electricity installations in the region now and, when available, the base of the existing manufacturing capacity in the region for renewable energy resources hardware and software. The possible barriers and considerations for renewable energy resources are presented.

03 NATURAL GAS↗

Impacts of Varying Penetration of Distributed Resources with & without Volt/Var Control: Case Study of Varying Load Types

This paper provides a follow-up to an earlier one on impacts of distributed energy resources (DR) on distribution feeders. As DR penetration level on the feeder increases, there can be impacts to distribution system/feeder capacity, line losses, and voltage regulation. These can vary as the penetration level reaches the capacity of the distribution feeder/system or loading. The question is how high of a DR level can be accommodated without any major changes to system operation, system design and protection. Our objective for this work was to address the question of how the DR impacts vary in regards to both DR voltage regulation capability and load mix. A dynamic analysis was used to focus on the impacts of DR with and without volt/var control with different load composition on the distribution feeder. The study considered an example 10MVA distribution feeder in which two inverter-based DRs were used to provide voltage regulation. The results due to DR without voltage regulation capability are compared with DR capable of providing local (at its bus) voltage regulation. The analysis was repeated for four different feeder load compositions consisting of (1) constant power, (2) constant impedance, (3) constant current and (4) ZIP (equal combination of previous three).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Side Voltage and PQ Control with Inverter-based Photovoltaic Systems

Distributed energy resources (DER) are small generators located close to the load centers. The DERs that are integrated to the grid with the power electronic converter interfaces are capable of providing nonactive power in addition to active power. Hence, they are capable of regulating the voltages of the weak buses in the distribution systems. This paper discusses the voltage control capability of photovoltaic (PV) systems as compared to the traditional capacitor banks. The simulation results prove the effectiveness of dynamic voltage control capability of inverter-based PV. With the proper control algorithm, the active and nonactive power from the DERs like battery banks or solar photovoltaic can be controlled independently. This paper also presents the scenario of controlling the active and nonactive power from the PV array to track and supply the local load.

99 GENERAL AND MISCELLANEOUS↗

Voltage and Current Unbalance Compensation Using a STATCOM

A three-phase insulated gate bipolar transistor (IGBT)-based static var compensator (STATCOM) is used for voltage and/or current unbalance compensation. An instantaneous power theory is adopted for real-time calculation and control. Three control schemes, current control, voltage control, and integrated control are proposed to compensate the unbalance of current, voltage, or both. The compensation results of the different control schemes in unbalance cases (load unbalance or voltage source unbalance) are compared and analyzed. The simulation and experimental results show that the control schemes can compensate the unbalance in load current or in the voltage source. Different compensation objectives can be achieved, i.e., balanced and unity power factor source current, balanced and regulated voltage, or both, by choosing appropriate control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Orbit of the Orphan Stream

We use recent SEGUE spectroscopy and SDSS and SEGUE imaging data to measure the sky position, distance, and radial velocities of stars in the tidal debris stream that is commonly referred to as the 'Orphan Stream.' We fit orbital parameters to the data, and find a prograde orbit with an apogalacticon, perigalacticon, and eccentricity of 90 kpc, 16.4 kpc and e = 0.7, respectively. Neither the dwarf galaxy UMa II nor the Complex A gas cloud have velocities consistent with a kinematic association with the Orphan Stream. It is possible that Segue-1 is associated with the Orphan Stream, but no other known Galactic clusters or dwarf galaxies in the Milky Way lie along its orbit. The detected portion of the stream ranges from 19 to 47 kpc from the Sun and is an indicator of the mass interior to these distances. There is a marked increase in the density of Orphan Stream stars near (l, b) = (253{sup o}; 49{sup o}), which could indicate the presence of the progenitor at the edge of the SDSS data. If this is the progenitor, then the detected portion of the Orphan Stream is a leading tidal tail. We find blue horizontal branch (BHB) stars and F turnoff stars associated with the Orphan Stream. The turnoff color is (g-r){sub 0} = 0.22. The BHB stars have a low metallicity of [Fe/H]{sub WBG} = -2.1. The orbit is best fit to a halo potential with a halo plus disk mass of about 2.6 x 10{sup 11} M{sub {circle_dot}}, integrated to 60 kpc from the Galactic center. Our fits are done to orbits rather than full N-body simulations; we show that if N-body simulations are used, the inferred mass of the galaxy would be slightly smaller. Our best fit is found with a logarithmic halo speed of v{sub halo} = 73 {+-} 24 km s{sup -1}, a disk+bulge mass of M(R < 60 kpc) = 1.3 x 10{sup 11} M{sub {circle_dot}}, and a halo mass of M(R < 60 kpc) = 1.4 x 10{sup 11} M{sub {circle_dot}}. However, we can find similar fits to the data that use an NFW halo profile, or that have smaller disk masses and correspondingly larger halo masses. Distinguishing between different classes of models requires data over a larger range of distances. The Orphan Stream is projected to extend to 90 kpc from the Galactic center, and measurements of these distant parts of the stream would be a powerful probe of the mass of the Milky Way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Instantaneous Active and Nonactive Power Control of Distributed Energy Resources with Current Limiter

Abstract -- Distributed energy resources (DER) with a power electronics inverter interface can provide both active power and nonactive power simultaneously and independently. A decoupled control algorithm of active power and nonactive power is developed based on the instantaneous active power and nonactive power theory. A current limiter is combined to the control algorithm, and it ensures that the inverter is not overloaded. During the normal system operation, the active power has higher priority over the nonactive power so that the energy from a DER can be fully transferred to the grid. Within the inverter s capability, nonactive power is provided to the grid as required. With this control algorithm, the inverter s capabilities are taken full advantage at all times, both in terms of functionality as well as making use of its full KVA rating. Through the algorithm, the inverter s active power and nonactive power are controlled directly, simultaneously, and independently. Several experimental results fully demonstrate the validity and effectiveness of this new control algorithm. As evidenced by the fast dynamic response that results, a DER system with the control algorithm can provide full services to the grid in both steady state and during transient events.

30 DIRECT ENERGY CONVERSION↗

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of the atmospheric pressure nonequilibrium plasmas on the conformational changes of plasmid DNA

The cold atmospheric pressure plasma, which has been widely used for biomedical applications, may potentially affect the conformation of DNA. In this letter, an atmospheric pressure plasma plume is used to investigate its effects on the conformational changes of DNA of plasmid pAHC25. It is found that the plasma plume could cause plasmid DNA topology alteration, resulting in the percentage of the supercoiled plasmid DNA form decreased while that of the open circular and linearized form of plasmid DNA increased as detected by agrose gel electrophoresis. On the other hand, further investigation by using polymerase chain reaction method shows that the atmospheric pressure plasma jet treatments under proper conditions does not affect the genes of the plasmid DNA, which may have potential application in increasing the transformation frequency by genetic engineering.

60 APPLIED LIFE SCIENCES↗

ORNL Laboratory Directed Research and Development Program FY 2008 Annual Report

The Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD) Program reports its status to the U.S. Department of Energy (DOE) in March of each year. The program operates under the authority of DOE Order 413.2B, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the Laboratory Director broad flexibility for program implementation. LDRD funds are obtained through a charge to all Laboratory programs. This report includes summaries all ORNL LDRD research activities supported during FY 2008. The associated FY 2008 ORNL LDRD Self-Assessment (ORNL/PPA-2008/2) provides financial data and an internal evaluation of the program’s management process.

08 HYDROGEN↗

An Adaptive Voltage Control Algorithm with Multiple Distributed Energy

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗