Search NASA⌕ Search

Engineering topics

Xu, Yan

Publications and source records attributed to Xu, Yan.

133 records · Page 8

Preventing Delayed Voltage Recovery with Voltage-Regulating Distributed Energy Resources

With the large use of residential air conditioner (A/C) motors during the summer peaks, the potential of motor stalling events have increased in the recent years. The stalled motor loads have been found to be the most important cause of delayed voltage recovery following severe system disturbances, such as a subtransmission fault. The proper modeling of the stalled motors is a very important factor in identifying the effect of these motors in voltage recovery after the fault. This paper presents a methodology for modeling the stalled low inertia induction motors based on a sample utility system and a small primary distribution circuit. The prevention of the stalling of motors plays an important role in maintaining the voltage profile of the system after system disturbances. Distributed Energy Resource (DER) is used to prevent the motor stalling events so that the delayed voltage recovery of the system may be avoided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crystallization and preliminary X-ray crystallographic analysis of a carbonyl reductase from Candida parapsilosis

A novel short-chain NADPH-dependent (S)-1-phenyl-1,2-ethanediol dehydrogenase (SCR) has been crystallized. A novel short-chain NADPH-dependent (S)-1-phenyl-1,2-ethanediol dehydrogenase (SCR) has been crystallized. Two distinct but related crystal forms of SCR were obtained using the hanging-drop vapour-diffusion method and a reservoir solution consisting of 18%(w/v) polyethylene glycol 2000 monomethyl ether and 8%(v/v) 2-propanol as the precipitant. The crystals were rhomboid in shape with average dimensions of 0.3 × 0.3 × 0.4 mm and diffracted to a resolution of 2.7–3.0 Å. The crystal forms both belong to space group P2{sub 1}2{sub 1}2{sub 1} and have unit-cell parameters a = 104.7, b = 142.8, c = 151.8 Å and a = 101.1, b = 146.0, c = 159.8 Å. The calculated values of V{sub M}, rotation-function and translation-function solutions and consideration of potential crystal packing suggest that there are eight protein subunits per asymmetric unit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Active Power and Nonactive Power Control of Distributed Energy Resources

Distributed energy resources (DE) have been widely used in the power systems to supply active power, and most of the present DE resources are operated with limited or without nonactive power capability. This paper shows that with a slight modification in hardware configuration and a small boost in the power ratings, as well as proper implementation of control strategies, a DE system with a power electronics converter interface can provide active power and nonactive power simultaneously and independently. A DE can provide dynamic voltage regulation to the local bus because of its nonactive power capability. Furthermore, the proposed DE control method in this paper can effectively compensate the unbalance in the local voltage. The system requirements such as the inverter current rating and the dc voltage rating are discussed. The analysis of the system requirements to provide nonactive power shows that it is cost-effective to have DE provide voltage regulation.

Distributed Generation↗

Interaction of Multiple Distributed Energy Resources in Voltage Regulation

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services; voltage regulation in particular has drawn much attention. In this paper the problem of how to coordinate control multiple DEs to regulate the local voltage in the distribution system is addressed. A control method for voltage regulation using the DE PE controller is presented and based on the proposed control scheme; the voltage regulation of a distribution system with one DE and two DEs are tested, respectively. The factors affecting the gain parameters of the PE controller are investigated. The simulation results show that the parameters of the controller determine its dynamic response for voltage regulation and the factors associated with the network characteristics, such as locations of DEs and the amount of load, affect the impact range of the controller. The research work presented in this paper can be potentially used for the control system design of Smart Grid or Utility of the Future.

distributed energy↗

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar full-disk magnetic field image receiving system and observation software

The paper introduces terminal hardware system of 10 cm high resolution full-disk magnetic field telescope among solar multi-channel telescope produced by Beijing Astronomical Observatory, and its software procedure by using imaging processing as well real time data collecting. These data were processed by Sun Workstation 470/4, including doing some spectrum analysis, the system is unique in the world now. It uses a set of CCD (1320 pixels plus 1035 pixels) of high resolution image explosion, also it has a set of fast and high resolution (1024 pixel plus 1024 pixel) image processor. Moreover, we can obtain higher time and space resolution about solar full-disk magnetic field and velocity field. This will provide excellent means in observation and studies of full-disk solar large-scale magnetic field and velocity field.