Search NASA⌕ Search

Engineering topics

Yang, J.

Publications and source records attributed to Yang, J..

At least 145 records · Page 8

Wishart AGU 2013

Shales are a component of the terrestrial subsurface biosphere and may be colonized by microorganisms when temperature and fluid flow are permitting. Assessing microbial community activity will be aided by the use of in situ sampling devices such as the osmosampler, an osmotically driven sampling device. Community analysis of shale samples remains a challenge and requires further methods development. The objectives of the work reported are: 1. to review geochemical and microbiological evidence for the possible microbial inhabitation of shale 2. to compare conditions among U.S. shale formations 3. to develop analytical techniques to evaluate microbial communities present in hydraulic fracturing fluid.

03 NATURAL GAS↗

Fe-24 wt.%Cr-4.1 wt.%C hardfacing alloy: Microstructure and carbide refinement mechanisms with ceria additive

The microstructure and carbide refinement mechanisms of Fe-24 wt.%Cr-4.1 wt.%C hardfacing alloys with 0 wt.%, 0.5 wt.%, 1.0 wt.%, 2 wt.%, and 4 wt.% ceria additives have been systematically investigated in this work. Optical microscopy, field emission scanning electron microscopy with energy dispersive spectrometer, and X-ray diffraction were collectively used to study the microstructure, the phase components, and the chemical formation of inclusion formed in the welding process. Wear-resistance of the alloys was comparatively studied using an abrasive wear testing machine. The structure analysis results show that the Fe-Cr-C hardfacing alloy mainly consists of martensite, retained austenite, MC carbide and M{sub 7}C{sub 3} carbide. With increasing ceria additive contents, the average size of the primary M{sub 7}C{sub 3} carbide decreases and reaches a most refined state in the alloy with 2 wt.% ceria additives. Comparative wear tests data shows that the wear resistance of the hardfacing alloys with ceria additives is better than that without ceria additive. In a good agreement with the carbide refinement results, the wear resistance of the alloy reaches an optimum level in the sample with 2 wt.% ceria additive. The main RE inclusion type identified with in-situ XRD analysis is RE inclusion Ce{sub 2}O{sub 2}S. Thermodynamics calculation confirms that this type of RE inclusion could precipitate prior to M{sub 7}C{sub 3} carbides, and act as a heterogeneous nucleus for M{sub 7}C{sub 3} in the welding process, which effectively provides a mechanism for significant refinement of the M{sub 7}C{sub 3} carbide and improves its wear resistance. - Graphical Abstract: Rare Earth inclusion (Ce{sub 2}O{sub 2}S) distributes in the primary M{sub 7}C{sub 3} carbide. Moreover, Ce{sub 2}O{sub 2}S, which acts as heterogeneous nuclei of the primary M{sub 7}C{sub 3} carbide, is medium effective. Therefore, the primary M{sub 7}C{sub 3} carbide has been refined. Highlights: Black-Right-Pointing-Pointer Micro-hardness of primary M{sub 7}C{sub 3} carbide in Fe-Cr-C hardfacing alloy is 1594 HV. Black-Right-Pointing-Pointer RE inclusion Ce{sub 2}O{sub 2}S can be observed in the primary M{sub 7}C{sub 3} carbide. Black-Right-Pointing-Pointer Ce{sub 2}O{sub 2}S as heterogeneous nuclei of the Cr{sub 7}C{sub 3} is medium effective. Black-Right-Pointing-Pointer Primary carbide is most refined with 2 wt.% ceria additive.

36 MATERIALS SCIENCE↗

Development of double-decker pulse radiolysis

Double-decker pulse radiolysis (DDPR), which utilizes double-decker electron beams, was investigated to develop a new pulse radiolysis with a high time resolution. The double-decker electron beams were generated by injecting two UV pulses into a photocathode radio-frequency gun. In the pulse radiolysis, one electron beam was used as a pump beam, and the other was converted to a probe pulse. Finally, as its first application, the DDPR was successfully used for observing solvated electrons in water, with a 10%-90% rise time of 8.6 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core design study of a supercritical light water reactor with double row fuel rods

An equilibrium core for supercritical light water reactor has been designed. A novel type of fuel assembly with dual rows of fuel rods between water rods is chosen and optimized to get more uniform assembly power distributions. Stainless steel is used for fuel rod cladding and structural material. Honeycomb structure filled with thermal isolation is introduced to reduce the usage of stainless steel and to keep moderator temperature below the pseudo critical temperature. Water flow scheme with ascending coolant flow in inner regions is carried out to achieve high outlet temperature. In order to enhance coolant outlet temperature, the radial power distributions needs to be as flat as possible through operation cycle. Fuel loading pattern and control rod pattern are optimized to flatten power distribution at inner regions. Axial fuel enrichment is divided into three parts to control axial power peak, which affects maximum cladding surface temperature. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ESBWR - Robust design for natural circulation and stability performance effectiveness

ESBWR is a 4500 MWt Generation III+ natural circulation reactor with an array of robust design features and passive safety systems to deliver highly effective plant performance during normal operation and to keep the reactor safe during postulated transients and accidents. With the submittal of the latest revision of the Design Control Document (DCD) to US Nuclear Regulatory Commission, ESBWR is nearing the completion of the US design certification process. This paper focuses on the natural circulation-driven plant performance aspects during normal operation, and stability evaluation of the robust ESBWR design. The TRACG computer code is used for the analysis of ESBWR plant performance, safety analysis, and stability margins. The paper describes the evaluation of ESBWR stability performance during normal power operation including operation in the Core Power-Feed Water Temperature Operating Domain. For ESBWR the normal power operation condition has the highest power/flow ratio and is limiting from the perspective of stability. The paper includes results from detailed evaluation of the most limiting decay ratio for out-of-phase regional oscillations calculated by perturbing the core inlet flow rate in this out-of-phase mode about the line of symmetry for the azimuthal harmonic mode. The paper also summarizes the ESBWR regional mode stability evaluations during a limiting transient (Loss of Feedwater Heating), and during ATWS (Anticipated Transient without Scram). Nominal decay ratios of limiting Channel oscillation, Core wide oscillation and Regional oscillation are within the maximum acceptance criterion of 0.8, at 95% content and 95% confidence. These stability evaluation results indicate decay ratio is within design limits. The paper also describes the evaluation of ESBWR stability performance during plant startup, and summarizes the defense-in-depth stability solution for ESBWR. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Subchannel analysis on CGNPC SCWR

SCWR, as one of the candidates of six generation 4 reactors, is the water cooled reactor operating above the critical point. The investigation on SCWR was popular worldwide and amount of concepts were proposed by different country. Chinese Guangdong Nuclear Power Company (CGNPC) also designed a SCWR based on the Double-row Assembly. Based on the power distribution in different stage of the fuel cycle obtained by neutronics physics, the first pass and the second pass were calculated using ATHAS code, respectively, and the maximum cladding temperatures were obtained, which was satisfied the design limitation. The sensitivity of the geometry parameters was analyzed, and the optimum on the assembly design was carried. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Best-estimate plus uncertainty thermal-hydraulic stability analysis of BWRs using TRACG code

Over the last decade, Boiling Water Reactor (BWR) power up-rates have increased plant rated power output significantly. Subsequent projects have expanded flow domains (e.g. MELLLA+) for operation at these higher power levels. This has resulted in an increase in the power to flow ratio in regions susceptible to reactor thermal-hydraulic instabilities. Since BWRs are susceptible to coupled thermal-hydraulic/nuclear oscillations when operating at these conditions, such oscillations must be prevented or reliably detected and suppressed. The Detect and Suppress Solution - Confirmation Density (DSS-CD) is the most sophisticated GEH BWR instability protection system ever employed. DSS-CD implements algorithms that monitor closely-spaced groups of Local Power Range Monitor (LPRM) detectors to detect periodic behavior typical of reactor instability events. This system is able to detect small, localized power variations in the core, distinguish between true instabilities and plant noise, and trip/scram the reactor while maintaining adequate safety margins. The combination of hardware, software, and system setpoints provides protection against violation of the Safety Limit Minimum Critical Power Ratio (SLMCPR) for anticipated oscillations. To support DSS-CD implementation, the TRACG system code is used to simulate events to confirm the capability of the DSS-CD solution for early oscillation detection and suppression. TRACG is a GEH proprietary version of the Transient Reactor Analysis Code (TRAC). TRACG includes a multi-dimensional, two-fluid model for the reactor thermal-hydraulics and a three-dimensional reactor kinetics model. The models are qualified to simulate a large variety of tests and reactor configurations, including thermal-hydraulic stability events. These features allow for detailed, best-estimate simulation of a wide range of BWR phenomena. A set of integrated TRACG event simulations for reasonably limiting anticipated events can be used to calculate the effect on the Minimum Critical Power Ratio (MCPR) performance. The purpose of the DSS-CD TRACG analysis is to confirm the inherent MCPR margin afforded by the solution design. This paper presents the Best Estimate Plus Uncertainty (BEPU) DSS-CD TRACG methodology and its application to BWR Thermal-Hydraulic (T-H) stability analyses. The statistical Code Scaling, Applicability and Uncertainty (CSAU) methodology (defined in NUREG/CR-5249) is used to calculate the MCPR uncertainty. The TRACG simulation includes a full core individual bundle model in which each fuel bundle is modeled as an individual T-H channel. The complete CSAU analysis of full core individual bundle model is an innovative solution represents the state-of-the-art stability analysis of BWRs and is the first ever full statistical analysis for stability safety analyses. The adoption of BEPU methodologies for stability analyses advances the understanding of the associated physical phenomena and maintains the safety of reactor plant operation in expanded operation domain with up-rated power. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat transfer research on supercritical water flow upward in tube

The experimental research of heat transfer on supercritical water has been carried out on the supercritical water multipurpose test loop with a 7.6 mm upright tube. The experimental data of heat transfer is obtained. The experimental results of thermal-hydraulic parameters on flow and heat transfer of supercritical water show that: Heat transfer enhancement occurs when the fluid temperature reaches pseudo-critical point with low mass flow velocity, and peters out when the mass flow velocity increases. The heat transfer coefficient and Nusselt number decrease with the heat flux or system pressure increases, and increase with the increasing of mass flow velocity. The wall temperature increases when the mass flow velocity decreases or the system pressure increases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LOFA and LOCA analysis on CGNPC SCWR

Safety analysis is one of the chief difficulties during the research and design of SCWRs. At present, the development of SCWR safety analysis code is still in the initial stage all around the world, and very few computer codes could carry out trans-critical calculations where significant changes in water properties would take place. In this paper, a safety analysis code SCTRAN for SCWRs, has been developed based on RETRAN-02. The ability of SCTRAN code to simulate the transient where both supercritical and subcritical regimes are encountered has been verified by comparing with APROS code and RELAP5-3D code, respectively. With SCTRAN code, the preliminary LOFA and LOCA analysis of the SCWR design proposed by CGNPC, have been analyzed. The characteristics and performance of the passive safety systems applied to CGNPC-SCWR are evaluated. The results show that: 1) The SCTRAN computer code developed in this study is capable to carry out safety analysis for SCWRs, and its results are reliable; 2) During LOFA and LOCA accidents, very complex flow regime might take place in the double-pass core design, but the passive safety systems would greatly mitigate the consequences of these transients and increase the inherent safety. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An analysis of the sliding pressure start-up of SCWR

In this paper, the preliminary sliding pressure start-up system and scheme of supercritical water-cooled reactor in CGNPC (CGN-SCWR) were proposed. Thermal-hydraulic behavior in start-up procedures was analyzed in detail by employing advanced reactor subchannel analysis software ATHAS. The maximum cladding temperature (MCT for short) and core power of fuel assembly during the whole start-up process were investigated comparatively. The results show that the recommended start-up scheme meets the design requirements from the perspective of thermal-hydraulic. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Critical heat flux in natural convection cooled TRIGA reactors with hexagonal bundle

A three-rod bundle Critical Heat Flux (CHF) study at low flow, low pressure, and natural convection condition has been conducted, simulating TRIGA reactors with the hexagonally configured core. The test section is a custom-made trefoil shape tube with three identical fuel pin heater rods located symmetrically inside. The full scale fuel rod is electrically heated with a chopped-cosine axial power profile. CHF experiments were carried out with the following conditions: inlet water subcooling from 30 K to 95 K; pressure from 110 kPa to 230 kPa; mass flux up to 150 kg/m{sup 2}s. About 50 CHF data points were collected and compared with a few existing CHF correlations whose application ranges are close to the testing conditions. Some tests were performed with the forced convection to identify the potential difference between the CHF under the natural convection and forced convection. The relevance of the CHF to test parameters is investigated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of BWR OPRM plant data and detection algorithms with DSSPP

All U.S. BWRs are required to have licensed stability solutions that satisfy General Design Criteria (GDC) 10 and 12 of 10 CFR 50 Appendix A. Implemented solutions are either detect and suppress or preventive in nature. Detection and suppression of power oscillations is accomplished by specialized hardware and software such as the Oscillation Power Range Monitor (OPRM) utilized in Option III and Detect and Suppress Solution - Confirmation Density (DSS-CD) stability Long-Term Solutions (LTSs). The detection algorithms are designed to recognize a Thermal-Hydraulic Instability (THI) event and initiate control rod insertion before the power oscillations increase much higher above the noise level that may threaten the fuel integrity. Option III is the most widely used long-term stability solution in the US and has more than 200 reactor years of operational history. DSS-CD represents an evolutionary step from the stability LTS Option III and its licensed domain envelopes the Maximum Extended Load Line Limit Analysis Plus (MELLLA +) domain. In order to enhance the capability to investigate the sensitivity of key parameters of stability detection algorithms, GEH has developed a new engineering analysis code, namely DSSPP (Detect and Suppress Solution Post Processor), which is introduced in this paper. The DSSPP analysis tool represents a major advancement in the method for diagnosing the design of stability detection algorithms that enables designers to perform parametric studies of the key parameters relevant for THI events and to fine tune these system parameters such that a potential spurious scram might be avoided. Demonstrations of DSSPPs application are also presented in this paper utilizing actual plant THI data. A BWR/6 plant had a plant transient that included unplanned recirculation pump transfer from fast to slow speed resulting in about 100% to {approx}40% rated power decrease and about 99% to {approx}30% rated core flow decrease. As the feedwater temperature is reduced to equilibrium conditions, the power increased from about {approx}40% to about {approx}60% with little change inflow. A THI event developed and subsequently, an OPRM initiated scram occurred with Option III. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chicagoland Single-Family Housing Characterization

In this report, the PARR team identifies housing characteristics and energy use for fifteen housing types (groups) in the Chicagoland (Cook County, Illinois) region and specifies measure packages that provide an optimum level of energy savings based on a BEopt analysis. The analysis is based on assessor data and actual energy consumption data on 432,605 houses representing approximately 30% ofthe population.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chicagoland Single-Family Housing Characterization

In this report, the PARR team identifies housing characteristics and energy use for fifteen housing types in the Chicagoland (Cook County, Illinois) region and specifies measure packages that provide an optimum level of energy savings based on a BEopt analysis. The analysis is based on assessor data and actual energy consumption data on 432,605 houses representing approximately 30% of the population.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗