Search NASA⌕ Search

Engineering topics

You, Shutang

Publications and source records attributed to You, Shutang.

At least 37 records · Page 2

A Review on Artificial Intelligence (AI) for Stability Assessment: Preprint

Artificial intelligence provides a convenient route for power grid stability assessment. Compared with simulation-based approaches, artificial intelligence can potentially save time on model development and numerical computation in stability assessment. This paper first reviewed existing literature on using artificial intelligence for power grid stability assessment. Then a machine-leaning-based tool is presented and developed to assess power grid transient stability, frequency stability, and small-signal stability. Test results verified the accuracy and effectiveness of the artificial intelligence tool for power grid stability assessment.

artificial intelligence↗

A Review on Artificial Intelligence for Grid Stability Assessment

Artificial intelligence provides a convenient route for power grid stability assessment. Compared with simulation-based approaches, artificial intelligence can potentially save time on model development and numerical computation in stability assessment. This paper first reviewed existing literature on using artificial intelligence for power grid stability assessment. Then a machine-leaning-based tool is presented and developed to assess power grid transient stability, frequency stability, and small signals stability. Test results verified the accuracy and effectiveness of the AI tool for power grid stability assessment.

You, Shutang↗

Impact of High PV Penetration on Voltage Stability

Photovoltaics (PV) are becoming increasingly relevant in modern power systems. With this increase also comes reliability concerns as photovoltaics behave differently than conventional generators. One reliability concern is voltage stability. In this paper, voltage stability of the Austin area in the Electric Reliability Council of Texas (ERCOT) system is studied using dynamic models with varying levels of photovoltaic penetration. The base case is set at 0% renewable penetration. Additional cases include 15% wind penetration and up to 65% photovoltaic penetration. The study results show that voltage/var control capacity is critical to voltage stability, which PV lacks. Voltage regulation of photovoltaics may cause over-voltage and voltage collapse may be more abrupt under high regional photovoltaic penetration.

Till, Jeremy↗

FNET/GridEye: A Tool for Situational Awareness of Large Power Interconnetion Grids

This paper gives an overview of a wide-area measurement system deployed at the distribution level: FNET/GridEye, which consists of hundreds of sensors, communication and a data center. The sensors are utilized to take frequency, voltage phase angle and magnitude measurements from the ordinary 110 or 220V outlets in offices or residential houses. These measurements are continuously transmitted to the data center via Internet. Many applications have been implemented to monitor large-scale interconnected power grids, and interpret grid operation status to improve system operators' situational awareness capability. Some representative online and offline applications are presented in this paper, as well as several recently developed new applications.

Zhu, Lin↗

A Review of Clean Electricity Policies—From Countries to Utilities

Due to the heavy stress on environmental deterioration and the excessive consumption of fossil resources, the transition of global energy from fossil fuel energy to clean energy has significantly accelerated in recent years. The power industry and policymakers in almost all countries are focusing on clean energy development. Thanks to progressive clean energy policies, significant progress in clean energy integration and greenhouse gas reduction has been achieved around the world. However, due to the differences in economic structures, clean energy distributions, and development models, clean energy policy scope, focus, and coverage vary between different countries, states, and utilities. This paper aims at providing a policy review for readers to easily obtain clean energy policy information on various clean energies in the U.S. and some other countries. Firstly, this paper reviews and compares some countries’ clean energy policies on electricity. Then, taking the U.S. as an example, this paper introduces the clean energy policies of some representative states and utilities in the U.S in perspectives of renewable energies, electric vehicles, and energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlation between Generator Trips and Locational Marginal Prices (LMPs)

Generally, disturbances in an interconnected network have an influence the stability and the economy of the power grid. Some phenomenon such as load shedding have proven to have a huge impact on real time electricity prices. Generation trip is considered one of the most common events in a power grid that may change the wholesale electricity market. In this paper, a locational marginal price (LMP) measure is used to notice how the electricity prices change with generator trip events at different locations of U.S. power grid. The study results help to find whether there is a clear correlation between generator trips and the changes in the electricity real-time market.

Alharbi, Abdulelah↗

Ambient Synchrophasor Measurement Based System Inertia Estimation

This paper develops an algorithm to estimate the system inertia value based on ambient synchrophasor measurement. Informative features are extracted from ambient synchrophasor measurements for machine-learning-based inertia estimation. Besides ambient synchrophasor measurements of FNET/GridEye, other available data relevant to inertia (such as weather and system load data) are also used to improve the inertia estimation accuracy. Then a machine learning algorithm to estimate system inertia is developed. A test dataset including ambient synchrophasor data from FNET/GridEye measurements and the WECC system inertia data from NERC is used to evaluate the performance of the developed inertia estimation method. The average and maximum estimation errors of the developed inertia estimation method is lower than 5% and 10%, respectively. This accuracy is higher than reported accuracy values in existing literature.

CUI, YI↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Advanced Synchrophasor-based Application for Potential Distributed Energy Resources Management: Key Technology, Challenge and Vision

With an increasing number of distributed energy resources (DERs) integrating into the power system, the power grid is becoming more complex and uncertain. Owing to most of DERs are through grid-connected converters to integrate into the power system, the intermittent nature and resource-depended characteristic of the DERs are challenging their monitoring and control. Conventional synchronized measurement devices (SMDs) may be difficult to provide qualified data for DERs management for its accuracy and reporting-rate limitation. The monitoring systems developed basing on SMDs may be insufficient for depicting detailed dynamic manifestations of power systems with a high proportion integration of DERs. This paper shares some advanced synchrophasor-based applications developed in FNET/GridEye, which have a broad prospect for assisting system operator on the control and integration of the DERs.

Wang, Weikang↗

Dynamic Equivalence of Large-Scale Power Systems Based on Boundary Measurements

Parallel computing helped speed up many tasks that can be done independently. The advance in gaming industry did not produce a technology that helps the power industry to reduce the computation time for dynamic simulation in individual cases. To perform faster than real-time simulation for the purpose of predicting power system dynamic trajectory, power industry continues to struggle to reduce the system size and simulation time of large-scale power systems while keeping its dynamic behavior under various disturbances. There is also an acute need for real-time dynamic model reduction as more renewables enter the generation mix with dramatic changes in the generation outputs. All existing model reduction solutions are based on having access to a detailed dynamic model of the system. The system changes by the minutes, dynamic models are only updated annually. To solve this problem, wide-area measurements obtained by the phasor measurement unit (PMU) at the boundaries between the reduced system and the study system is used to represent the external area. An artificial neuro-fuzzy inference system (ANFIS) is established to perform the mapping of the measurement to the external equivalent model. Here the external area is regarded as a black-box. Model reduction studies are conducted on the Northeast Power Coordinating Council (NPCC) under various types of contingencies, by using a co-simulation approach between PSS/E and MATLAB. The results look very promising and will be discussed in this paper.

Tong, Ning↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Model-Free Data Authentication for Cyber Security in Power Systems

With the development and wide deployment of measurement equipment, data can be automatically measured and visualized for situation awareness in power systems. However, the cyber security of power systems is also threated by data spoofing attacks. This letter proposed a measurement data source authentication (MDSA) algorithm based on feature extraction techniques including ensemble empirical mode decomposition (EEMD) and fast Fourier transform (FFT), and machine learning for real-time measurement data classification. Compared with previous work, the proposed algorithm can achieve higher accuracy of MDSA using a shorter window of data from closely located synchrophasor measurement sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal photovoltaic (PV) power plants reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. On a realistic 1-day operation profile of the WECC system, the ML model demonstrates a savings of more than 40% PV headroom compared to a conservative approach.

14 SOLAR ENERGY↗

Impact of simultaneous activities on frequency fluctuations — comprehensive analyses based on the real measurement data from FNET/GridEye

Simultaneous human activities such as the Super Bowl game would cause certain impacts on frequency fluctuations in power systems. With the help of FNET/GridEye measurements, this work aims to give comprehensive analyses on the frequency fluctuations during Super Bowl LIV held on Feb. 2, 2020, so as to better understand several phenomena caused by simultaneous activities and help system operation and control. First, recent developments of FNET/GridEye are introduced briefly. Second, the frequency fluctuations of Eastern Interconnection (EI), western electricity coordinating council (WECC), and electric reliability council of Texas (ERCOT) power systems during Super Bowl LIV are analyzed. Third, frequency fluctuations of Super Bowl Sunday and ordinary Sundays in 2020 are compared. Finally, the differences of frequency fluctuations among different years during the Super Bowl and their change trend are also given. Furthermore, several possible explanations including the simultaneity of electricity consumption at the beginning of commercial breaks and the halftime show, the increasing usage of the Internet, and the increasing size of TV screens are illustrated in detail in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage for Frequency Control in High Photovoltaic Power Grids

Frequency stability of power systems becomes more vulnerable with the increase of solar photovoltaic (PV). Energy storage provides an option to mitigate high PV impact. Using the United States Eastern Interconnection (EI) and Texas Interconnection (ERCOT) power grid models, this paper investigates the capabilities of using energy storage to improve frequency stability of high PV power grids. The study result helps to identify the potential and impact factors in utilizing energy storage to regulate frequency in high renewable power grids.

14 SOLAR ENERGY↗

Power system disturbance location determination based on rate of change of frequency

A method for determining a location of a disturbance in a power system is provided. The method includes receiving data from a plurality of sensors distributed across the power system; determining, with one or more processors, for each sensor, an extremum of the data corresponding to the sensor; interpolating, with the one or more processors, the extrema; and presenting, on one or more display units, a location corresponding to a global maximum of the interpolated extrema as the location of the disturbance. The method may further include, if a difference between the largest extremum and each of remaining extremum is greater than a predetermined threshold, skipping the interpolating step and the presenting step, and presenting a location of the sensor corresponding to the largest extremum as the location of the disturbance.

You, Shutang↗

A Fast Load Control System Based on Mobile Distribution-Level Phasor Measurement Unit

The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of our work is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel Mobile Distribution-level Phasor Measurement Unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the Rate Of Change Of Frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also examined. Finally, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗