Search NASA⌕ Search

Engineering topics

Zhang, D.

Publications and source records attributed to Zhang, D..

At least 73 records · Page 4

TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

Measurement of neutrino flux from neutrino-electron elastic scattering

Muon-neutrino elastic scattering on electrons is an observable neutrino process whose cross section is precisely known. Consequently, a measurement of this process in an accelerator-based ν μ beam can improve the knowledge of the absolute neutrino flux impinging upon the detector; typically this knowledge is limited to ~10% due to uncertainties in hadron production and focusing. We also isolated a sample of 135±17 neutrino-electron elastic scattering candidates in the segmented scintillator detector of MINERvA, after subtracting backgrounds and correcting for efficiency. We show how this sample can be used to reduce the total uncertainty on the NuMI ν μ flux from 9% to 6%. Finally, our measurement provides a flux constraint that is useful to other experiments using the NuMI beam, and this technique is applicable to future neutrino beams operating at multi-GeV energies.

43 PARTICLE ACCELERATORS↗

The investigation of ferromagnetic resonance linewidth in Ni{sub 80}Fe{sub 20} films with submicron rectangular elements

Patterned magnetic films with nano-scaled dots exhibit some special magnetic properties. In this paper, we investigate the in-plane shape anisotropy and the magnetization dynamic damping in permalloy (Ni{sub 80}Fe{sub 20}) arrays of submicron rectangular elements using ferromagnetic resonance (FMR). The FMR linewidth exhibits a dependence on the element size, and mainly comes from the contribution of the intrinsic damping. Also the contribution of two-magnon scattering plays an important role and is reduced with increasing aspect ratio. The damping coefficient decreases from 0.0129 to 0.0118 with the element length increasing from 300 nm to 1200 nm, and the theoretical calculation suggests that the change of damping results from the longitudinal and transverse interlayer spin current due to the spatially inhomogeneous magnetization dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of electron neutrino quasielastic and quasielasticlike scattering on hydrocarbon at $\langle E_{\nu} \rangle $ = 3.6 GeV

The first direct measurement of electron neutrino quasielastic and quasielasticlike scattering on hydrocarbon in the few-GeV region of incident neutrino energy has been carried out using the MINERvA detector in the NuMI beam at Fermilab. The flux-integrated differential cross sections in the electron production angle, electron energy, and Q 2 are presented. The ratio of the quasielastic, flux-integrated differential cross section in Q 2 for ν e with that of similarly selected ν μ -induced events from the same exposure is used to probe assumptions that underpin conventional treatments of charged-current νe interactions used by long-baseline neutrino oscillation experiments. Furthermore, the data are found to be consistent with lepton universality and are well described by the predictions of the neutrino event generator GENIE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standard Model Prediction for Direct C P Violation in K → π π Decay

In this paper, we report the first lattice QCD calculation of the complex kaon decay amplitude A 0 with physical kinematics, using a 32 3 x 64 lattice volume and a single lattice spacing a, with 1/a = 1.3784(68) GeV. We find Re(A 0 ) = 4.66(1.00)(1.26) x 10 -7 GeV and Im(A 0 ) = -1.90(1.23)(1.08) x 10 -11 GeV, where the first error is statistical and the second systematic. The first value is in approximate agreement with the experimental result: Re(A 0 ) = 3.3201(18) x 10 -7 GeV, while the second can be used to compute the direct CP-violating ratio Re(ϵ'/ϵ) = 1.38(5.15)(4.59) x 10 -4 , which is 2.1σ below the experimental value 16.6(2.3) x 10 -4 . Finally, the real part of A 0 is CP conserving and serves as a test of our method while the result for Re(ϵ'/ϵ) provides a new test of the standard model theory of CP violation, one which can be made more accurate with increasing computer capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single neutral pion production by charged-current ν ¯ μ interactions on hydrocarbon at 〈 E ν 〉 = 3.6 GeV

We studied single neutral pion production via muon antineutrino charged-current interactions in plastic scintillator (CH) using the MINERvA detector exposed to the NuMI low-energy, wideband antineutrino beam at Fermilab. Measurement of this process constrains models of neutral pion production in nuclei, which is important because the neutral-current analog is a background for appearance oscillation experiments. Furthermore, the differential cross sections for π 0 momentum and production angle, for events with a single observed π 0 and no charged pions, are presented and compared to model predictions. These results comprise the first measurement of the π 0 kinematics for this process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

Permeation of hydrogen in hastelloy C-276 alloy at high temperature

Tritium is generated by the interaction of neutrons with the lithium and beryllium in the molten salt reactors (MSRs), which use FLiBe as one of solvents of fluoride fuel. Tritium as by-product in the MSRs is an important safety issue because it could easily diffuse into environment through high temperature heat exchangers. The experimental technique of gas driven permeation has been used to investigate the transport parameter of hydrogen in Hastelloy C-276 which is considered as one of the candidate for structure materials. The measurements were carried out at the temperature range of 400-800 Celsius degrees with hydrogen loading pressures ranging from 5*10{sup 3} to 4*10{sup 4} Pa. The H diffusive transport parameters for Hastelloy C-276 follow an Arrhenius law in this temperature range. Regarding diffusivity and Sieverts' constant, Hastelloy C-276 has lower values compared with Ni201 alloy. The possible reason may be the trapping effects, which were formed by the alloying elements of Mo and Cr in the matrix. At the same time, the thin oxidation layer formed by the high Cr content could lead to a slower dissociation process of H{sub 2} at the surface. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optical probing of MgZnO/ZnO heterointerface confinement potential energy levels

Low-temperature photoluminescence and reflectance measurements were employed to study the optical transitions present in two-dimensional electron systems confined at Mg{sub x}Zn{sub 1–x}O/ZnO heterojunctions. Transitions involving A- and B-holes and electrons from the two lowest subbands formed within the confinement potential are detected. In the studied density range of 2.0–6.5 × 10{sup 11 }cm{sup −2}, the inter-subband splitting is measured and the first excited electron subband is shown to be empty of electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An intercalation-locked parallel-stranded DNA tetraplex

DNA has proved to be an excellent material for nanoscale construction because complementary DNA duplexes are programmable and structurally predictable. However, in the absence of Watson–Crick pairings, DNA can be structurally more diverse. Here, we describe the crystal structures of d(ACTCGGATGAT) and the brominated derivative, d(AC Br UCGGA Br UGAT). These oligonucleotides form parallel-stranded duplexes with a crystallographically equivalent strand, resulting in the first examples of DNA crystal structures that contains four different symmetric homo base pairs. Two of the parallel-stranded duplexes are coaxially stacked in opposite directions and locked together to form a tetraplex through intercalation of the 5'-most A–A base pairs between adjacent G–G pairs in the partner duplex. The intercalation region is a new type of DNA tertiary structural motif with similarities to the i-motif. 1 H– 1 H nuclear magnetic resonance and native gel electrophoresis confirmed the formation of a parallel-stranded duplex in solution. Finally, we modified specific nucleotide positions and added d(GAY) motifs to oligonucleotides and were readily able to obtain similar crystals. This suggests that this parallel-stranded DNA structure may be useful in the rational design of DNA crystals and nanostructures.

Tripathi, S.↗

Layer-dependent electronic structure of an atomically heavy two-dimensional dichalcogenide

Here we report angle-resolved photoemission spectroscopic measurements of the evolution of the thickness-dependent electronic band structure of the atomically heavy two-dimensional layered dichalcogenide, tungsten diselenide ( WS e 2 ) . Our data, taken on mechanically exfoliated WS e 2 single crystals, provide direct evidence for shifting of the valence-band maximum from Γ ¯ (multilayer WS e 2 ) to K ¯ (single-layer WS e 2 ). Further, our measurements also set a lower bound on the energy of the direct band gap and provide direct measurement of the hole effective mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the diagnostics development for the first operation phase of the stellarator Wendelstein 7-X

An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic anisotropies in epitaxial Fe{sub 3}O{sub 4}/GaAs(100) patterned structures

Previous studies on epitaxial Fe{sub 3}O{sub 4} rings in the context of spin-transfer torque effect have revealed complicated and undesirable domain structures, attributed to the intrinsic fourfold magnetocrystalline anisotropy in the ferrite. In this Letter, we report a viable solution to this problem, utilizing a 6-nm-thick epitaxial Fe{sub 3}O{sub 4} thin film on GaAs(100), where the fourfold magnetocrystalline anisotropy is negligible. We demonstrate that in the Fe{sub 3}O{sub 4} planar wires patterned from our thin film, such a unique magnetic anisotropy system has been preserved, and relatively simple magnetic domain configurations compared to those previous reports can be obtained.

36 MATERIALS SCIENCE↗

The impact of microwave stray radiation to in-vessel diagnostic components

Microwave stray radiation resulting from unabsorbed multiple reflected ECRH / ECCD beams may cause severe heating of microwave absorbing in-vessel components such as gaskets, bellows, windows, ceramics and cable insulations. In view of long-pulse operation of WENDELSTEIN-7X the MIcrowave STray RAdiation Launch facility, MISTRAL, allows to test in-vessel components in the environment of isotropic 140 GHz microwave radiation at power load of up to 50 kW/m{sup 2} over 30 min. The results show that both, sufficient microwave shielding measures and cooling of all components are mandatory. If shielding/cooling measures of in-vessel diagnostic components are not efficient enough, the level of stray radiation may be (locally) reduced by dedicated absorbing ceramic coatings on cooled structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗