Search NASA⌕ Search

Engineering topics

Zhang, D.

Publications and source records attributed to Zhang, D..

At least 91 records · Page 5

Measurement of Ratios of ν μ Charged-Current Cross Sections on C, Fe, and Pb to CH at Neutrino Energies 2–20 GeV

We present measurements of ν μ charged-current cross section ratios on carbon, iron, and lead relative to a scintillator (CH) using the fine-grained MINERvA detector exposed to the NuMI neutrino beam at Fermilab. The measurements utilize events of energies 2 < E ν < 20 GeV , with ( E ν ) = 8 GeV , which have a reconstructed μ - scattering angle less than 17° to extract ratios of inclusive total cross sections as a function of neutrino energy E ν and flux-integrated differential cross sections with respect to the Bjorken scaling variable x . These results provide the first high-statistics direct measurements of nuclear effects in neutrino scattering using different targets in the same neutrino beam. Measured cross section ratios exhibit a relative depletion at low x and enhancement at large x . Both become more pronounced as the nucleon number of the target nucleus increases. The data are not reproduced by GENIE , a conventional neutrino-nucleus scattering simulation, or by the alternative models for the nuclear dependence of inelastic scattering that are considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided by five different beamlines of Physikalische Technische Bundesanstalt at the electron storage rings BESSY II and Metrology Light Source in Berlin. For the measurements in the visible range, a setup was realised using monochromatized halogen lamp radiation and a calibrated laser power meter as reference. The measurements clearly demonstrate that the efficiency of the bolometer prototype detectors in the range from 50 eV up to ≈6 keV is close to unity; at a photon energy of 20 keV the bolometer with the thick absorber detects 80% of the photons, the one with the thin absorber about 50%. This indicates that the detectors will be well capable of measuring the plasma radiation expected from the standard ITER scenario. However, a minimum absorber thickness will be required for the high temperatures in the central plasma. At 11.56 keV, the sharp Pt-L{sub 3} absorption edge allowed to cross-check the absorber thickness by fitting the measured efficiency to the theoretically expected absorption of X-rays in a homogeneous Pt-layer. Furthermore, below 50 eV the efficiency first follows the losses due to reflectance expected for Pt, but below 10 eV it is reduced further by a factor of 2 for the thick absorber and a factor of 4 for the thin absorber. Most probably, the different histories in production, storage, and operation led to varying surface conditions and additional loss channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency and accuracy of the perturbation response coefficient generation method for whole core comet calculations in BWR and CANDU configurations

The coarse mesh transport method (COMET) is a highly accurate and efficient computational tool which predicts whole-core neutronics behaviors for heterogeneous reactor cores via a pre-computed eigenvalue-dependent response coefficient (function) library. Recently, a high order perturbation method was developed to significantly improve the efficiency of the library generation method. In that work, the method's accuracy and efficiency was tested in a small PWR benchmark problem. This paper extends the application of the perturbation method to include problems typical of the other water reactor cores such as BWR and CANDU bundles. It is found that the response coefficients predicted by the perturbation method for typical BWR bundles agree very well with those directly computed by the Monte Carlo method. The average and maximum relative errors in the surface-to-surface response coefficients are 0.02%-0.05% and 0.06%-0.25%, respectively. For CANDU bundles, the corresponding quantities are 0.01%-0.05% and 0.04% -0.15%. It is concluded that the perturbation method is highly accurate and efficient with a wide range of applicability. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aspects of steady-state operation of the Wendelstein 7-X stellarator

The objective of Wendelstein 7-X is to demonstrate steady-state operation at -values of up to 5%, at ion temperatures of several keV and plasma densities of up to 2 1020 m 3. The second operational phase foresees a fully steady-state high heat flux (HHF) divertor. Preparations are underway to cope with residual bootstrap currents, either by electron cyclotron current drive or by HHF protection elements. The main steady-state heating system is an electron cyclotron resonance heating facility. Various technical improvements of the gyrotrons have been implemented recently. They enable a reliable operation at the 1MW power level. Some of the technical issues preparing plasma diagnostics for steady-state operation are exemplified. This includes the protection against non-absorbed microwave radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comet whole-core solution to a stylized 3-dimensional pressurized water reactor benchmark problem with UO{sub 2}and MOX fuel

A stylized pressurized water reactor (PWR) benchmark problem with UO{sub 2} and MOX fuel was used to test the accuracy and efficiency of the coarse mesh radiation transport (COMET) code. The benchmark problem contains 125 fuel assemblies and 44,000 fuel pins. The COMET code was used to compute the core eigenvalue and assembly and pin power distributions for three core configurations. In these calculations, a set of tensor products of orthogonal polynomials were used to expand the neutron angular phase space distribution on the interfaces between coarse meshes. The COMET calculations were compared with the Monte Carlo code MCNP reference solutions using a recently published an 8-group material cross section library. The comparison showed both the core eigenvalues and assembly and pin power distributions predicated by COMET agree very well with the MCNP reference solution if the orders of the angular flux expansion in the two spatial variables and the polar and azimuth angles on the mesh boundaries are 4, 4, 2 and 2. The mean and maximum differences in the pin fission density distribution ranged from 0.28%-0.44% and 3.0%-5.5%, all within 3-sigma uncertainty of the MCNP solution. These comparisons indicate that COMET can achieve accuracy comparable to Monte Carlo. It was also found that COMET's computational speed is 450 times faster than MCNP. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Whole-core comet solutions to a 3-dimensional PWR benchmark problem with gadolinium

A pressurized water reactor (PWR) benchmark problem with gadolinium was used to determine the accuracy and computational efficiency of the coarse mesh radiation transport method COMET. The benchmark problem contains 193 square fuel assemblies. The COMET solution (eigenvalue, assembly averaged and fuel pin averaged fission density distributions) was compared with those obtained from the corresponding Monte Carlo reference solution using the same 2-group material cross section library. The comparison showed that both the core eigenvalue and fission density distribution averaged over each assembly and fuel pin predicated by COMET agree very well with the corresponding MCNP reference solution if the incident flux response expansion used in COMET is truncated at 2nd order in the two spatial and the two angular variables. The benchmark calculations indicate that COMET has Monte Carlo accuracy. In, particular, the eigenvalue difference between the codes ranged from 17 pcm to 35 pcm, being within 2 standard deviations of the calculational uncertainty. The mean flux weighted relative differences in the assembly and fuel pin fission densities were 0.47% and 0.65%, respectively. It was also found that COMET's full (whole) core computational speed is 30,000 times faster than MCNP in which only 1/8 of the core is modeled. It is estimated that COMET would have been about over 6 orders of magnitude faster than MCNP if the full core were also modeled in MCNP. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comet solutions to a stylized BWR benchmark problem

In this paper, a stylized 3-D BWR benchmark problem was used to evaluate the performance of the coarse mesh radiation transport method COMET. The benchmark problem consists of 560 fuel bundles at 3 different burnups and 3 coolant void states. The COMET solution was compared with the corresponding Monte Carlo reference solution using the same 2-group material cross section library for three control blade (rod) configurations, namely, all rods out (ARO), all rods in (ARI) and some rods in (SRJ). The differences in the COMET and MCNP eigenvalues were 43 pcm, 66 pcm and 32 pcm for the ARO, ARI and SRI cases, respectively. These differences are all within 3 standard deviations of the COMET uncertainty. The average relative differences in the bundle averaged fission densities for these three cases were 0.89%, 1.24%, and 1.05%, respectively. The corresponding differences in the fuel pin averaged fission densities were 1.24%, 1.84% and 1.29%, respectively. It was found that COMET is 3,000 times faster than Monte Carlo, while its statistical uncertainty in the fuel pin fission density is much lower than that of Monte Carlo (i.e., {approx}40 times lower). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Highly c-axis oriented GaN films grown on free-standing diamond substrates for high-power devices

Highlights: {yields} GaN films are deposited on diamond substrates by ECR-PEMOCVD. {yields} Influence of deposition temperature on the properties of samples is investigated. {yields} Properties of GaN films are dependent on the deposition temperature. -- Abstract: GaN films with highly c-axis preferred orientation are deposited on free-standing thick diamond films by low temperature electron cyclotron resonance plasma enhanced metal organic chemical vapor deposition (ECR-PEMOCVD). The TMGa and N{sub 2} are applied as precursors of Ga and N, respectively. The quality of as-grown GaN films are systematically investigated as a function of deposition temperature by means of X-ray diffraction (XRD) analysis, Hall Effect measurement (HL), room temperature photoluminescence (PL) and atomic force microscopy (AFM). The results show that the dense and uniformed GaN films with highly c-axis preferred orientation are successfully achieved on free-standing diamond substrates under optimized deposition temperature of 400 {sup o}C, and the room temperature PL spectra of the optimized GaN film show a intense ultraviolet near band edge emission and a weak yellow luminescence. The obtained GaN/diamond structure has great potential for the development of high-power semiconductor devices due to its excellent heat dissipation nature.

36 MATERIALS SCIENCE↗

TAK1 is activated in the myocardium after pressure overload and is sufficient to provoke heart failure in transgenic mice

The transforming-growth-factor-beta-activated kinase TAK1 is a member of the mitogen-activated protein kinase kinase kinase family, which couples extracellular stimuli to gene transcription. The in vivo function of TAK1 is not understood. Here, we investigated the potential involvement of TAK1 in cardiac hypertrophy. In adult mouse myocardium, TAK1 kinase activity was upregulated 7 days after aortic banding, a mechanical load that induces hypertrophy and expression of transforming growth factor beta. An activating mutation of TAK1 expressed in myocardium of transgenic mice was sufficient to produce p38 mitogen-activated protein kinase phosphorylation in vivo, cardiac hypertrophy, interstitial fibrosis, severe myocardial dysfunction, 'fetal' gene induction, apoptosis and early lethality. Thus, TAK1 activity is induced as a delayed response to mechanical stress, and can suffice to elicit myocardial hypertrophy and fulminant heart failure.

NASA Discipline Cardiopulmonary↗

Electrical signal transmission in a bone cell network: the influence of a discrete gap junction

A refined electrical cable model is formulated to investigate the role of a discrete gap junction in the intracellular transmission of electrical signals in an electrically coupled system of osteocytes and osteoblasts in an osteon. The model also examines the influence of the ratio q between the membrane's electrical time constant and the characteristic time of pore fluid pressure, the circular, cylindrical geometry of the osteon, and key simplifying assumptions in our earlier continuous cable model (see Zhang, D., S. C. Cowin, and S. Weinbaum. Electrical signal transmission and gap junction regulation in a bone cell network: A cable model for an osteon. Ann. Biomed. Eng. 25:379-396, 1997). Using this refined model, it is shown that (1) the intracellular potential amplitude at the osteoblastic end of the osteonal cable retains the character of a combination of a low-pass and a high-pass filter as the corner frequency varies in the physiological range; (2) the presence of a discrete gap junction near a resting osteoblast can lead to significant modulation of the intracellular potential and current in the osteoblast for measured values of the gap junction coupling strength; and (3) the circular, cylindrical geometry of the osteon is well simulated by the beam analogy used in Zhang et al.

Non-NASA Center↗