Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Ambient-Frequency-Data Based System-Level Inertia Estimation Using Physical Equation and its Practice on Hawaii Islands

Here, in this paper, a practical ambient-frequency-data-based inertia estimation method using a physical equation is proposed and validated by real measurement data from Hawaii island grids. With high renewable penetration, accurate inertia estimation is important and urgent. Ambient frequency oscillation always exists in power grids, so the proposed method has advantages of real-time inertia estimation and no need for additional disturbances. This paper first developed the physical equation for inertia estimation to offer a clear mechanism for easy implementation in practice. To apply the proposed method in actual grids, a practical method to extract the ambient frequency oscillation from frequency measurement is further proposed. The inertia estimation using the physical equation is validated by KIUC simulation data and HECO field data, in which error rates are around 2% and 8%, respectively. Practical inertia estimation is challenging due to the large amounts of resources contributing to the power grid's effective inertia, but the method provided in this paper can offer a novel way for practical inertia estimation, which can help renewable penetration to boost carbon-free grid.

14 SOLAR ENERGY↗

Fast Quasi-Static Time-Series Simulation for Accurate PV Inverter Semiconductor Fatigue Analysis with a Long-Term Solar Profile

Power system simulations with long-term data typically have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stress cycle occurs over the fundamental grid frequency (50 or 60 Hz). This requires the time step of the fatigue simulation to be around 100 µs. This small time step requires long computation times to process yearly power production profiles. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The proposed simulation calculates the steady state of the semiconductor junction temperature by using a Fast Fourier Transform (FFT). The small thermal cycling during a switching period and even over the fundamental waveform is disregarded to further accelerate the simulation speed. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset. The error of the proposed simulation is 0.16% compared to the fatigue simulation results using the complete thermal stress profile. A PV inverter that responds to a Transactive Energy System (TES) is simulated to demonstrate the use of the proposed fatigue simulation. The proposed simulation has the potential to co-simulate with system level simulation tools that also adopt the QSTS concept.

Liu, Yunting↗

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Deep Learning Based Frequency Stability Assessment in Power Grid with High Renewables

Frequency stability assessment is one critical aspect of power system security assessment. Traditional N-1 screening method is based on the simulations of a few typical daily and seasonal operation scenarios. However, the increasing integration of inverter-based renewables and the retirement of conventional synchronous generators result in decreasing system inertia and growing complexity of system operating conditions. Selecting a few typical operation scenarios cannot cover all operating conditions, and the time-domain simulation of all operation conditions requires tremendous time. This paper proposes a more efficient frequency stability assessment method based on deep learning. The affinity propagation clustering algorithm is used to divide the dataset into different clusters, so the selected dataset for training can cover the diversified operating conditions as much as possible. Also, feature normalization is applied to both the training dataset and testing dataset in order to remove any unnecessary bias. Especially, trained model based on full dataset normalization has bounded error in the prediction. The case study on the reduced 240-bus WECC system demonstrates that the proposed method can predict accurate frequency nadir with limited training dataset. The deep learning model using the revised feature normalization can predict more accurate frequency nadir than that using the traditional feature normalization and has very small maximum prediction error.

affinity propagation↗

A Fast and Accurate Transient Stability Assessment Method Based on Deep Learning: WECC Case Study

Transient stability is one of the critical aspects of power system stability assessment. The increasing integration of inverter-based resources and the retirement of conventional synchronous generators result in the decreasing system inertia and growing complexity of system operating conditions. Using a few selected typical operating conditions cannot guarantee system transient stability in all operating conditions, and the time-domain simulation of all operating conditions requires tremendous time and is often infeasible. This paper proposes a more efficient transient stability assessment method based on deep learning. The binary search method is used to determine the critical clearing time (CCT) in creating training databased by time-domain simulation. This method is fast and accurate with 1 ms resolution. The buses whose CCTs are lower than 200 ms are considered critical buses. Buses close to each other are grouped based on their mutual admittance matrix to reduce the search space of the critical buses. This paper also proposes the generator feature normalization based on the physical model. Case study on the reduced 240-bus WECC system model demonstrates that the proposed method can predict CCT accurately and efficiently.

critical clearing time↗

Forced Oscillation Grid Vulnerability Analysis and Mitigation Using Inverter-Based Resources: Texas Grid Case Study

Forced oscillation events have become a challenging problem with the increasing penetration of renewable and other inverter-based resources (IBRs), especially when the forced oscillation frequency coincides with the dominant natural oscillation frequency. A severe forced oscillation event can deteriorate power system dynamic stability, damage equipment, and limit power transfer capability. This paper proposes a two-dimension scanning forced oscillation grid vulnerability analysis method to identify areas/zones in the system that are critical to forced oscillation. These critical areas/zones can be further considered as effective actuator locations for the deployment of forced oscillation damping controllers. Additionally, active power modulation control through IBRs is also proposed to reduce the forced oscillation impact on the entire grid. The proposed methods are demonstrated through a case study on a synthetic Texas power system model. The simulation results demonstrate that the critical areas/zones of forced oscillation are related to the areas that highly participate in the natural oscillations and the proposed oscillation damping controller through IBRs can effectively reduce the forced oscillation impact in the entire system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Quasi-Static Time Series Fatigue Simulation for PV Inverter Semiconductors with Long-Term Solar Profile

Power system simulations with long-term data tend to have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stresses cycle is with line frequency. This requires the time step of the fatigue simulation to be much smaller than the line period. This small time step results in poor simulation speed, especially for long-term simulations. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The fatigue analysis typically focuses on the peak and valley values of a strain and neglect the transients from peaks to valleys. The proposed simulation utilizes this property of fatigue analysis and calculates the steady state of the semiconductor junction temperature only. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset without losing accuracy.

fast simulation↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Adding power of artificial intelligence to situational awareness of large interconnections dominated by inverter‐based resources

Abstract Large‐scale power systems exhibit more complex dynamics due to the increasing integration of inverter‐based resources (IBRs). Therefore, there is an urgent need to enhance the situational awareness capability for better monitoring and control of power grids dominated by IBRs. As a pioneering Wide‐Area Measurement System, FNET/GridEye has developed and implemented various advanced applications based on the collected synchrophasor measurements to enhance the situational awareness capability of large‐scale power grids. This study provides an overview of the latest progress of FNET/GridEye. The sensors, communication, and data servers are upgraded to handle ultra‐high density synchrophasor and point‐on‐wave data to monitor system dynamics with more details. More importantly, several artificial intelligence (AI)‐based advanced applications are introduced, including AI‐based inertia estimation, AI‐based disturbance size and location estimation, AI‐based system stability assessment, and AI‐based data authentication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning-Based Adaptive Remedial Action Scheme with Security Margin for Renewable-Dominated Power Grids

The Remedial Action Scheme (RAS) is designed to take corrective actions after detecting predetermined conditions to maintain system transient stability in large interconnected power grids. However, since RAS is usually designed based on a few selected typical operating conditions, it is not optimal in operating conditions that are not considered in the offline design, especially under frequently and dramatically varying operating conditions due to the increasing integration of intermittent renewables. The deep learning-based RAS is proposed to enhance the adaptivity of RAS to varying operating conditions. During the training, a customized loss function is developed to penalize the negative loss and suggest corrective actions with a security margin to avoid triggering under-frequency and over-frequency relays. Simulation results of the reduced United States Western Interconnection system model demonstrate that the proposed deep learning–based RAS can provide optimal corrective actions for unseen operating conditions while maintaining a sufficient security margin.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GMLC 1.5.03: Increasing Distribution System Resiliency using Flexible DER and Microgrid Assets Enabled by OpenFMB (Duke-RDS Final Report)

This is the final project report for the Grid Modernization Laboratory Consortium (GMLC) Resilient Distribution System (RDS) project titled “Increasing Distribution System Resiliency using Flexible DER and Microgrid Assets Enabled by OpenFMB”. The primary goal of this project was to increase the resiliency of distribution systems at utilities around the nation by deploying flexible operating strategies that engage end-use assets as a resource.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Method to Mitigate Forced Oscillations in Large Interconnected Power Grids

Multiple severe forced oscillation events have recently been observed across the North American interconnections and around the world. These forced oscillations have caused power swings, limited power transfer capability, damaged equipment, and persisted indefinitely until the driving source was located and removed. This paper proposes a comprehensive method to mitigate forced oscillations. Once a forced oscillation is detected, a new source location algorithm can be used to locate the source based on the oscillation mode angle without requiring system topology information. If the source cannot be quickly located and removed, a control strategy can be activated to modulate the active power of utility-scale inverterbased battery energy storage systems (BESSs) to reduce the energy of forced oscillations to a safe level and allow sufficient time for locating the exact source. The proposed source location algorithm is validated using measurements collected during the January 11, 2019 forced oscillation event in North America and other actual grid events, while the proposed control strategy is verified using the Eastern Interconnection dynamic model under the replicated January 11, 2019 forced oscillation event. The simulation results demonstrated that the proposed source location algorithm can accurately identify the forced oscillation source, and the proposed control strategy can significantly reduce forced oscillation energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗