Search NASA⌕ Search

Engineering topics

Zhu, Lin

Publications and source records attributed to Zhu, Lin.

At least 37 records · Page 2

Modeling of Marginal Cost for PV Inverter Ancillary Services Considering Inverter Aging under Transactive Energy Framework

PV inverters can provide ancillary services while providing active power. Transactive energy system (TES) incentivizes PV inverter to provide ancillary services and compensates for the cost of additional power losses due to additional reactive power production. However, providing ancillary services can shorten the lifetime of the PV inverter since additional reactive power increases the thermal stress of the PV inverter. This paper theoretically derives the lifetime shortening effect of a PV inverter when providing ancillary services. Based on the lifetime estimation, an improved marginal cost curve for the PV inverter ancillary services is derived. The improved marginal cost quantitively describe the willingness of the PV inverter to provide ancillary services by the given active power production and the ambient temperature. The proposed model is validated by a simulation case study.

Liu, Yunting↗

VOLTTRON™ Agent Development for Enabling Reactive Power Support of Non-Utility DERs by Integrating Transactive Energy Approach

To enable better voltage regulation in power systems with high penetration of photovoltaics (PV) and other distributed energy resources (DERs), future inverters are required to provide reactive power support to the grid in addition to providing real power generated by PV panels. This paper develops a framework that coordinates the support from DER-based inverters, which are grid-connected non-utility assets, by using a transactive energy approach. Results of the implementation demonstrate participation of DER-based inverters can be achieved by using the coordination between distributed controllers and a centralized controller. With the transactive energy approach, both the customer and utility can achieve benefits that meet their individual needs.

Kritprajun, Paychuda↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

Model-less Source Location for Forced Oscillation based on Synchrophasor and Moving Fast Fourier Transformation

Forced oscillations in power systems occur when the grid is driven by an external and periodic force. To quickly detect and locate the source of the forced oscillation is critical in terms of ensuring the reliability of an interconnected power grid. This paper explores the electromechanical wave propagation theory and the Fast Fourier Transformation to analyze the forced oscillations. It proposes a model-less, adaptive, fast, and accurate source location algorithm. The proposed algorithm is extensively evaluated through simulation data from a 70k-bus U.S. Eastern Interconnection test system and field-collected synchrophasor data from the distribution-level wide-area monitoring system, FNET/GridEye. The evaluation results demonstrate the correctness and effectiveness of the proposed model-less forced oscillation source location algorithm.

Wang, Weikang↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

FNET/GridEye: A Tool for Situational Awareness of Large Power Interconnetion Grids

This paper gives an overview of a wide-area measurement system deployed at the distribution level: FNET/GridEye, which consists of hundreds of sensors, communication and a data center. The sensors are utilized to take frequency, voltage phase angle and magnitude measurements from the ordinary 110 or 220V outlets in offices or residential houses. These measurements are continuously transmitted to the data center via Internet. Many applications have been implemented to monitor large-scale interconnected power grids, and interpret grid operation status to improve system operators' situational awareness capability. Some representative online and offline applications are presented in this paper, as well as several recently developed new applications.

Zhu, Lin↗

Dynamic Equivalence of Large-Scale Power Systems Based on Boundary Measurements

Parallel computing helped speed up many tasks that can be done independently. The advance in gaming industry did not produce a technology that helps the power industry to reduce the computation time for dynamic simulation in individual cases. To perform faster than real-time simulation for the purpose of predicting power system dynamic trajectory, power industry continues to struggle to reduce the system size and simulation time of large-scale power systems while keeping its dynamic behavior under various disturbances. There is also an acute need for real-time dynamic model reduction as more renewables enter the generation mix with dramatic changes in the generation outputs. All existing model reduction solutions are based on having access to a detailed dynamic model of the system. The system changes by the minutes, dynamic models are only updated annually. To solve this problem, wide-area measurements obtained by the phasor measurement unit (PMU) at the boundaries between the reduced system and the study system is used to represent the external area. An artificial neuro-fuzzy inference system (ANFIS) is established to perform the mapping of the measurement to the external equivalent model. Here the external area is regarded as a black-box. Model reduction studies are conducted on the Northeast Power Coordinating Council (NPCC) under various types of contingencies, by using a co-simulation approach between PSS/E and MATLAB. The results look very promising and will be discussed in this paper.

Tong, Ning↗

Dynamic Model Reduction for Large-Scale Power Systems Using Wide-Area Measurements

To perform faster than the real-time dynamic simulation of large-scale power systems, it is necessary to reduce the simulated system size by using equivalents for surrounding areas of the study area, and existing dynamic model reduction approach could provide the needed structure of the reduced area. However, further parameter optimization is required to achieve the desired accuracy. In this paper, a particle swarm optimization (PSO) based approach is used to solve the above problem. Parameters for the individual dynamic elements in the reduced system are calibrated repeatedly until the wide-area measurements of the reduced model and the original model are very similar to each other with satisfactory accuracy. Results indicate that after optimization, the dynamic response of the reduced model matches better with that of the original one than using existing methods. Under both the generator-trip event and the bus-fault event, the reduced model has a higher frequency match and less power mismatch.

42 ENGINEERING↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility’s historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility's historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Microgrids with dynamically configurable boundaries including multiple main grid feeder coupling locations and methods of operating the same

An energy system includes a microgrid including a network of at least one distributed energy resource and a plurality of loads, the at least one distributed energy resource being configured to supply power to the plurality of loads. The microgrid is configurable to connect to one of a plurality of feeder circuits of a main power grid at one of a plurality of coupling interface locations, respectively. The microgrid is also configurable to expand or shrink its power supply area according to the available power generation capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing Power System Transient Stability by Virtual Synchronous Generator Control Using Wide-Area Measurements

Virtual synchronous generator control provides a potential solution to connect power electronics interfaced sources to the power system. With its flexible control, the emulated inertia may be adaptively changed to enhance system small-signal stability. However, previously proposed methods may have adverse impact to system transient stability. This paper proposes to improve the methods by using wide-area measurements, namely center of inertia frequency. Experimental results are presented to both demonstrate the limitations of previous control schemes, and the effectiveness of the proposed one. The practical implementation of this method is discussed.

Ma, Yiwei↗

Development of a Converter Based Microgrid Test Platform

To overcome the limitations of digital simulation (numerical oscillation, limited computing capability of processors, etc.), a converter-based hardware test-bed was developed at CURENT for real-time power grid emulation. However, distribution systems especially microgrids cannot be emulated and tested on the existing hardware test-bed. This paper develops a microgrid test-bed based on the existing hardware test-bed to enable controller testing for microgrids with dynamic boundary. The design and realization of the microgrid hardware test-bed are introduced. The experimental results of the microgrid controller tests are also provided.

Li, Dingrui↗

Self–Destruction of Cancer Induced by Ag 2 S Amorphous Nanodots

Studies on distinctive performances and novel applications of amorphous inorganic nanomaterials are becoming attractive. Herein, Ag 2 S amorphous and crystalline nanodots (ANDs and CNDs) are prepared via facile methods. In vitro and in vivo studies indicate that Ag 2 S ANDs, rather than CNDs, can induce the self-destruction of tumors, which can be attributed to their distinctive chemical properties, e.g., the higher electrochemical active surface area and lower redox potential well matching with the redox reaction requirement in the tumor microenvironment. Ag 2 S ANDs can be oxidized by intracellular reactive oxygen species (ROS) to release Ag + , which further stimulates high generation of intracellular ROS. This mutual stimulation damages the mitochondria, induces apoptosis, and leads to the self-destruction of the tumor. Moreover, Ag 2 S ANDs do not show observable in vitro and in vivo side effects. Furthermore, these findings provide a promising self-destructive strategy for cancer therapy by utilizing distinctive chemical properties of inorganic nanomaterials, while avoiding complicated external assistance.

60 APPLIED LIFE SCIENCES↗

Learning Heterogeneous Features Jointly: A Deep End-to-End Framework for Multi-Step Short-Term Wind Power Prediction

Leveraging multiple heterogeneous measurements to predict wind power has long been a challenging task in the electrical community. In this paper, a deep architecture incorporated with multitask learning and multimodal learning for wind power prediction, termed predictive stacked autoencoder (PSAE), is presented. PSAE is a unified framework integrating multiple stacked autoencoders (SAEs), one feature fusion layer, and one prediction terminal layer, which expands the architecture from two spatial dimensions, including the depth and width, compared to conventional prediction models. Initially, the SAEs at the bottom of PSAE extracted features from multiple kinds of measurements respectively. Following, the feature fusion layer encodes the high-order features extracted by different SAEs into a unified feature that is more informative and representative for wind power prediction. Finally, the prediction terminal layer functions as a regression machine which generates the predicted targets based on the fusion features. Trained in an end-to-end (E2E) manner, PSAE is capable of learning heterogeneous features jointly and achieving the prediction task of sequence-to-sequence (S2S). Experiments for multi-step short-term predictions are conducted on real-world data, and the results demonstrate the superiority of PSAE to prior methods.

17 WIND ENERGY↗

Synthesis of calcium carbonate nanoparticles in erythrocytes enables efficient removal of extracellular lead ions

The “cyborg cells”, living cells with built-in nanoscaffolds, which could integrate the biological function of the cells with the functionality of nanomaterials, have been rarely explored. Here we report a method to construct “cyborg erythrocytes” through the in situ reaction of exogenous calcium and carbonate ions to generate calcium carbonate nanodots inside erythrocytes. The intracellular calcium carbonate nanodots combined with proteins are hidden under the membrane of erythrocytes, which can restrict migration and unexpected accumulation of nanodots in the body, improving the biosecurity of the nanodots. Most importantly, the calcium carbonate nanodots not only do not bring adverse effects on the nature of erythrocytes, but also endow erythrocytes with new properties. The in vitro and in vivo results show that the “cyborg erythrocytes” can remove 80% of lead ions in a blood poisoning model and reduce the lead level in the kidney and liver of mice through a precipitation transformation mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗